The DOI matches its Crossref record.
CT Radiation Dose and Iterative Reconstruction Techniques
Abstract
1. CT radiation dose optimization is one of the major concerns for the scientific community. 2. CT image quality is dependent on the selected image reconstruction algorithm. 3. Iterative reconstruction algorithms have reemerged with the potential of radiation dose optimization by lowering image noise. 4. Tube current is the most common parameter used to reduce radiation dose along with iterative reconstruction. 5. Tube potential (kV) is also used for dose optimization with iterative reconstruction in CT angiography protocols and small patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018) · Radiology · doi:10.1148/radiol.2018172361 · Cited by 622
A review on medical imaging synthesis using deep learning and its clinical applications
Wang, T., Lei, Y., Fu, Y., Wynne, J. F., Curran, W. J., Liu, T., & Yang, X. (2021) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.13121 · Cited by 279
Artificial Intelligence in Emergency Radiology: Where Are We Going?
Cellina, M., Cè, M., Irmici, G., Ascenti, V., Caloro, E., Bianchi, L., Pellegrino, G., D’Amico, N., Papa, S., & Carrafiello, G. (2022) · Diagnostics · doi:10.3390/diagnostics12123223 · Cited by 62
Metadata
- Authors
- Padole, A., Ali Khawaja, R. D., Kalra, M. K., & Singh, S.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2015-04
- Volume
- 204
- Issue
- 4
- Pages
- W384-W392
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2034903235
- Cited by
- 247
- References
- 0
- FWCI
- 15.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT Radiation Dose and Iterative Reconstruction Techniques. https://app.cochat.ai/papers/10.2214/ajr.14.13241
- The paper
- Padole, A., Ali Khawaja, R. D., Kalra, M. K., & Singh, S. (2015). CT Radiation Dose and Iterative Reconstruction Techniques. American Journal of Roentgenology. https://doi.org/10.2214/ajr.14.13241
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.