Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 622

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters

Open access
Berenguer, Roberto, Pastor-Juan, María del Rosario, Canales-Vázquez, Jesús, Castro-García, Miguel, Villas, María Victoria, Mansilla Legorburo, Francisco, Sabater, Sebastià·2018·Radiology

Abstract

Purpose To identify the reproducible and nonredundant radiomics features (RFs) for computed tomography (CT). Materials and Methods Two phantoms were used to test RF reproducibility by using test-retest analysis, by changing the CT acquisition parameters (hereafter, intra-CT analysis), and by comparing five different scanners with the same CT parameters (hereafter, inter-CT analysis). Reproducible RFs were selected by using the concordance correlation coefficient (as a measure of the agreement between variables) and the coefficient of variation (defined as the ratio of the standard deviation to the mean). Redundant features were grouped by using hierarchical cluster analysis. Results A total of 177 RFs including intensity, shape, and texture features were evaluated. The test-retest analysis showed that 91% (161 of 177) of the RFs were reproducible according to concordance correlation coefficient. Reproducibility of intra-CT RFs, based on coefficient of variation, ranged from 89.3% (151 of 177) to 43.1% (76 of 177) where the pitch factor and the reconstruction kernel were modified, respectively. Reproducibility of inter-CT RFs, based on coefficient of variation, also showed large material differences, from 85.3% (151 of 177; wood) to only 15.8% (28 of 177; polyurethane). Ten clusters were identified after the hierarchical cluster analysis and one RF per cluster was chosen as representative. Conclusion Many RFs were redundant and nonreproducible. If all the CT parameters are fixed except field of view, tube voltage, and milliamperage, then the information provided by the analyzed RFs can be summarized in only 10 RFs (each representing a cluster) because of redundancy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2018172361

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 622

Metadata

Authors
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S.
Venue
Radiology
Published
2018-08
Volume
288
Issue
2
Pages
407-415
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2801894005
Cited by
622
References
32
FWCI
43.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters. https://app.cochat.ai/papers/10.1148/radiol.2018172361
The paper
Berenguer, R., Pastor-Juan, M. D. R., Canales-Vázquez, J., Castro-García, M., Villas, M. V., Mansilla Legorburo, F., & Sabater, S. (2018). Radiomics of CT Features May Be Nonreproducible and Redundant: Influence of CT Acquisition Parameters. Radiology. https://doi.org/10.1148/radiol.2018172361

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.