The DOI matches its Crossref record.
Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent
Abstract
Chelation of the rare-earth element gadolinium (Gd) with diethylenetriaminepentaacetic acid (DTPA) results in a strongly paramagnetic, stable complex that is well tolerated in animals. The strongly paramagnetic gadolinium complex reduces hydrogen-proton relaxation times even in low concentrations (less than 0.01 mmol/L). The pharmacokinetic behavior of intravenously delivered Gd-DTPA is similar to the well known iodinated contrast agents used in urography and angiography; excretion is predominantly through the kidneys with greater than 90% recovery in 24 hr. The intravenous LD50 of the meglumine salt of Gd-DTPA is 10 mmol/kg for the rat; in vivo there is no evidence of dissociation of the gadolinium ion from the DTPA ligand. The combination of strong proton relaxation, in-vivo stability, rapid urinary excretion, and high tolerance favors the further development and the potential clinical application of gadolinium-DTPA as a contrast enhancer in magnetic resonance imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Muller, M. P., Jiang, T., Sun, C., Lihan, M., Pant, S., Mahinthichaichan, P., Trifan, A., & Tajkhorshid, E. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00608 · Cited by 282
Clinical Safety and Diagnostic Value of the Gadolinium Chelate Gadoterate Meglumine (Gd-DOTA)
Herborn, C. U., Honold, E., Wolf, M., Kemper, J., Kinner, S., Adam, G., & Barkhausen, J. (2007) · Investigative Radiology · doi:10.1097/01.rli.0000248893.01067.e5 · Cited by 126
Gadolinium-Based Contrast Agent Use, Their Safety, and Practice Evolution
Do, C., DeAguero, J., Brearley, A., Trejo, X., Howard, T., Escobar, G. P., & Wagner, B. (2020) · Kidney360 · doi:10.34067/kid.0000272019 · Cited by 125
Gadolinium-DTPA-enhanced magnetic resonance imaging in optic neuropathies
Guy, J., Mancuso, A., Quisling, R. G., Beck, R., & Moster, M. (1990) · Ophthalmology · doi:10.1016/s0161-6420(90)32537-x · Cited by 90
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Metadata
- Authors
- Weinmann, H., Brasch, R., Press, W., & Wesbey, G.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1984-03-01
- Volume
- 142
- Issue
- 3
- Pages
- 619-624
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2059864970
- Cited by
- 1,231
- References
- 0
- FWCI
- 27.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.