The DOI matches its Crossref record.
Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex
Abstract
Gadolinium (Gd)-DTPA complex was assessed as a nuclear magnetic resonance (NMR) contrast-enhancing agent by experimentally imaging normal and diseased animals. After intravenous injection, Gd-DTPA, a strongly paramagnetic complex by virtue of unpaired electrons, was rapidly excreted into the urine of rats, producing an easily observable contrast enhancement on NMR images in kidney parenchyma and urine. Spin-echo intensity of urine within the renal pelvis increased from 2263 to 4414 units; intensity of renal parenchyma increased from 2901 to 3893 after administration of 0.1 mmol/kg Gd-DTPA. Sterile soft-tissue abscesses demonstrated an obvious rim pattern of enhancement. A focus of radiation-induced brain damage in a canine model was only faintly detectable on spin-echo NMR images before contrast administration; after 0.5 mmol/kg Gd-DTPA administration, the lesion intensity increased from 3867 to 5590. In comparison, the normal brain with an intact blood-brain barrier remained unchanged in NMR characterization. Gd-DTPA is a promising new NMR contrast enhancer for the clinical assessment of renal function, of inflammatory lesions, and of focal disruption of the blood-brain barrier.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI
Gong, E., Pauly, J. M., Wintermark, M., & Zaharchuk, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25970 · Cited by 351
Gadolinium-DTPA-enhanced magnetic resonance imaging in optic neuropathies
Guy, J., Mancuso, A., Quisling, R. G., Beck, R., & Moster, M. (1990) · Ophthalmology · doi:10.1016/s0161-6420(90)32537-x · Cited by 90
Metadata
- Authors
- Brasch, R., Weinmann, H., & Wesbey, G.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1984-03-01
- Volume
- 142
- Issue
- 3
- Pages
- 625-630
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2134814559
- Cited by
- 302
- References
- 0
- FWCI
- 22.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex. https://app.cochat.ai/papers/10.2214/ajr.142.3.625
- The paper
- Brasch, R., Weinmann, H., & Wesbey, G. (1984). Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex. American Journal of Roentgenology. https://doi.org/10.2214/ajr.142.3.625
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.