Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 1, Principles and Techniques
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this article is to provide an overview of ultrasound and MR elastography, including a glossary of relevant terminology, a classification of elastography techniques, and a discussion of their respective strengths and limitations. CONCLUSION: Elastography is an emerging technique for the noninvasive assessment of mechanical tissue properties. These techniques report metrics related to tissue stiffness, such as shear-wave speed, magnitude of the complex shear modulus, and the Young modulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738 · cited 1×
“Ultrasound-Based Dynamic Elastography All current ultrasound-based dynamic elastography techniques use transient shearwave excitations at a frequency of 50–400 Hz depending on the technique [2, 13, 14].”
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476 · cited 2×
“The prototype is Supersonic Shear Imaging developed by SuperSonic Imagine [34].”
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 1×
“Pulse Sequence Various motion-sensitized MRI sequences, including gradient-recalled echo [4], spin-echo [42], echo-planar imaging [39, 43], and steadystate free precession [44], may be used to track the shear waves traversing the tissue of interest.”
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727 · cited 1×
“The absorbed acoustic energy causes the tissue to expand [31], which creates shear waves perpendicular to the ultrasound beam axis [1].”
Performance of Transient Elastography for the Staging of Liver Fibrosis: A Meta-Analysis
Friedrich–Rust, M., Ong, M., Martens, S., Sarrazin, C., Bojunga, J., Zeuzem, S., & Herrmann, E. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.01.034 · Cited by 1,490 · cited 1×
“Young modulus thresholds using the M-probe have been proposed for different causes of chronic liver disease, which facilitates interpretation of results [24].”
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198 · cited 1×
“For these reasons, it can be used by clinicians at the point of service, which is a major advantage [23].”
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108 · cited 8×
“On the commercial Acuson S2000 and S3000 systems (Siemens Healthcare), acoustic radiation force impulses are implemented for qualitative (not further discussed) and quantitative applications.”
MethodInfluentialUltrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052 · cited 1×
“5 MHz at a window depth of 35– 75 mm [19, 22].”
D'hooge, J. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0031 · Cited by 990 · cited 1×
“, the heart [7] or blood vessels [8]).”
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Cited by
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
Nonalcoholic fatty liver disease
Brunt, E. M., Wong, V. W.-S., Nobili, V., Day, C. P., Sookoian, S., Maher, J. J., Bugianesi, E., Sirlin, C. B., Neuschwander-Tetri, B. A., & Rinella, M. E. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.80 · Cited by 818
Self-citationLimitations of non-invasive tests for assessment of liver fibrosis
Patel, K., & Sebastiani, G. (2020) · JHEP Reports · doi:10.1016/j.jhepr.2020.100067 · Cited by 317
Liver fibrosis assessment: MR and US elastography
Ozturk, A., Olson, M. C., Samir, A. E., & Venkatesh, S. K. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03269-4 · Cited by 168
Deep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
Self-citationZhang, Y., Zhang, M., Jiang, S., Hu, H., Wang, X., Yu, F., Huang, Y., & Liang, Y. (2024) · Cancer Causes & Control · doi:10.1007/s10552-024-01865-5 · Cited by 5
“Values range from 100 to 400 dB/m, with higher values indicating higher hepatic fat content [35, 36].”
Metadata
- Authors
- Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2015-07
- Volume
- 205
- Issue
- 1
- Pages
- 22-32
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1979482831
- Cited by
- 216
- References
- 46
- FWCI
- 13.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.