Ultrasound Elastography and MR Elastography for Assessing Liver Fibrosis: Part 1, Principles and Techniques
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this article is to provide an overview of ultrasound and MR elastography, including a glossary of relevant terminology, a classification of elastography techniques, and a discussion of their respective strengths and limitations. CONCLUSION: Elastography is an emerging technique for the noninvasive assessment of mechanical tissue properties. These techniques report metrics related to tissue stiffness, such as shear-wave speed, magnitude of the complex shear modulus, and the Young modulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738 · cited 1×
“Ultrasound-Based Dynamic Elastography All current ultrasound-based dynamic elastography techniques use transient shearwave excitations at a frequency of 50–400 Hz depending on the technique [2, 13, 14].”
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476 · cited 2×
“The prototype is Supersonic Shear Imaging developed by SuperSonic Imagine [34].”
Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain Waves
Muthupillai, R., Lomas, D. J., Rossman, P. J., Greenleaf, J. F., Manduca, A., & Ehman, R. L. (1995) · Science · doi:10.1126/science.7569924 · Cited by 2,116 · cited 1×
“Pulse Sequence Various motion-sensitized MRI sequences, including gradient-recalled echo [4], spin-echo [42], echo-planar imaging [39, 43], and steadystate free precession [44], may be used to track the shear waves traversing the tissue of interest.”
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727 · cited 1×
“The absorbed acoustic energy causes the tissue to expand [31], which creates shear waves perpendicular to the ultrasound beam axis [1].”
Performance of Transient Elastography for the Staging of Liver Fibrosis: A Meta-Analysis
Friedrich–Rust, M., Ong, M., Martens, S., Sarrazin, C., Bojunga, J., Zeuzem, S., & Herrmann, E. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.01.034 · Cited by 1,490 · cited 1×
“Young modulus thresholds using the M-probe have been proposed for different causes of chronic liver disease, which facilitates interpretation of results [24].”
Bamber, J., Cosgrove, D., Dietrich, C., Fromageau, J., Bojunga, J., Calliada, F., Cantisani, V., Correas, J.-M., D'Onofrio, M., Drakonaki, E., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335205 · Cited by 1,198 · cited 1×
“For these reasons, it can be used by clinicians at the point of service, which is a major advantage [23].”
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108 · cited 8×
“On the commercial Acuson S2000 and S3000 systems (Siemens Healthcare), acoustic radiation force impulses are implemented for qualitative (not further discussed) and quantitative applications.”
MethodInfluentialUltrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052 · cited 1×
“5 MHz at a window depth of 35– 75 mm [19, 22].”
D'hooge, J. (2000) · European Journal of Echocardiography · doi:10.1053/euje.2000.0031 · Cited by 990 · cited 1×
“, the heart [7] or blood vessels [8]).”
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
Yin, M., Talwalkar, J. A., Glaser, K. J., Manduca, A., Grimm, R. C., Rossman, P. J., Fidler, J. L., & Ehman, R. L. (2007) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2007.06.012 · Cited by 948 · cited 1×
“This is taken to mean the magnitude of the complex modulus, also in kilopascals [46– 49].”
An introduction to seismology, earthquakes, and earth structure
(2003) · Choice Reviews Online · doi:10.5860/choice.40-4625 · Cited by 944 · cited 1×
“In contrast, shear waves produce tissue (particle) motion in a direction perpendicular to wave propagation [10].”
Magnetic Resonance Elastography for the Noninvasive Staging of Liver Fibrosis
Huwart, L., Sempoux, C., Vicaut, E., Salameh, N., Annet, L., Danse, E., Peeters, F., ter Beek, L. C., Rahier, J., Sinkus, R., et al. (2008) · Gastroenterology · doi:10.1053/j.gastro.2008.03.076 · Cited by 731
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680 · cited 1×
“Mathematic inversion algorithms currently require simplifying assumptions about tissue properties [45], including that it has a uniform density of 1 g/cm3 and that it is purely viscoelastic with locally (microscopically) homogeneous, isotropic, and linear mechanical properties.”
Ferraioli, G., Tinelli, C., Dal Bello, B., Zicchetti, M., Filice, G., Filice, C., & on behalf of the Liver Fibrosis Study Group (2012) · Hepatology · doi:10.1002/hep.25936 · Cited by 667 · cited 1×
“Compared with transient elastography and point shear-wave elastography, shear-wave elastography has restricted product availability, and, currently, there are fewer studies on its diagnostic performance for assessment of liver fibrosis [13, 36, 37].”
Shear-wave generation using acoustic radiation force: in vivo and ex vivo results
Nightingale, K. R., McAleavey, S. A., & Trahey, G. E. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.08.008 · Cited by 641
Myers, R. P., Pomier–Layrargues, G., Kirsch, R., Pollett, A., Duarte–Rojo, A., Wong, D., Beaton, M., Levstik, M., Crotty, P., & Elkashab, M. (2012) · Hepatology · doi:10.1002/hep.24624 · Cited by 503 · cited 2×
“Although the various probes produce similar results in phantoms, the XL probe provides lower stiffness estimates than the M probe in humans [25, 30].”
Friedrich‐Rust, M., Nierhoff, J., Lupsor, M., Sporea, I., Fierbinteanu‐Braticevici, C., Strobel, D., Takahashi, H., Yoneda, M., Suda, T., Zeuzem, S., et al. (2012) · Journal of Viral Hepatitis · doi:10.1111/j.1365-2893.2011.01537.x · Cited by 475 · cited 1×
“Nevertheless, there are sufficient publications for a pooled meta-analysis on the diagnostic performance of point shear-wave elastography for staging of liver fibrosis [33].”
Chen, J., Talwalkar, J. A., Yin, M., Glaser, K. J., Sanderson, S. O., & Ehman, R. L. (2011) · Radiology · doi:10.1148/radiol.11101942 · Cited by 432
Shear elasticity probe for soft tissues with 1-D transient elastography
Sandrin, L., Tanter, M., Gennisson, J.-L., Catheline, S., & Fink, M. (2002) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.996561 · Cited by 427 · cited 6×
“The prototype is FibroScan developed by Echosens [17].”
MethodInfluentialAcoustic Radiation Force Impulse (ARFI) Imaging: A Review
Nightingale, K. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038657 · Cited by 408 · cited 1×
“The absorbed acoustic energy causes the tissue to expand [31], which creates shear waves perpendicular to the ultrasound beam axis [1].”
Muller, M., Gennisson, J.-L., Deffieux, T., Tanter, M., & Fink, M. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.08.018 · Cited by 400 · cited 3×
“An ultra-high frame rate (up to 15,000 images per second) is used to scan the entire imaging plane in one acquisition with high temporal resolution [13].”
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380 · cited 1×
“Pulse Sequence Various motion-sensitized MRI sequences, including gradient-recalled echo [4], spin-echo [42], echo-planar imaging [39, 43], and steadystate free precession [44], may be used to track the shear waves traversing the tissue of interest.”
Huwart, L., Sempoux, C., Salameh, N., Jamart, J., Annet, L., Sinkus, R., Peeters, F., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2007) · Radiology · doi:10.1148/radiol.2452061673 · Cited by 365 · cited 1×
“Publications using investigational implementations have reported additional parameters, such as storage (G′) and loss modulus (G′′) [39] or elasticity and viscosity, by assuming a Kelvin-Voigt model [50].”
Nonalcoholic Fatty Liver Disease: US-based Acoustic Radiation Force Impulse Elastography
Yoneda, M., Suzuki, K., Kato, S., Fujita, K., Nozaki, Y., Hosono, K., Saito, S., & Nakajima, A. (2010) · Radiology · doi:10.1148/radiol.10091662 · Cited by 348 · cited 1×
“Shear-wave speed is related to tissue stiffness; for instance, shear waves travel faster in stiff (inflamed, fibrotic, or cirrhotic) liver and slower in soft (normal or fatty) liver [9].”
Assessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264 · cited 1×
“Pulse Sequence Various motion-sensitized MRI sequences, including gradient-recalled echo [4], spin-echo [42], echo-planar imaging [39, 43], and steadystate free precession [44], may be used to track the shear waves traversing the tissue of interest.”
Assessment of Liver Viscoelasticity by Using Shear Waves Induced by Ultrasound Radiation Force
Chen, S., Sanchez, W., Callstrom, M. R., Gorman, B., Lewis, J. T., Sanderson, S. O., Greenleaf, J. F., Xie, H., Shi, Y., Pashley, M., et al. (2013) · Radiology · doi:10.1148/radiol.12120837 · Cited by 258 · cited 1×
“Ultrasound-Based Dynamic Elastography All current ultrasound-based dynamic elastography techniques use transient shearwave excitations at a frequency of 50–400 Hz depending on the technique [2, 13, 14].”
Advanced Fibrosis in Nonalcoholic Fatty Liver Disease: Noninvasive Assessment with MR Elastography
Kim, D., Kim, W. R., Talwalkar, J. A., Kim, H. J., & Ehman, R. L. (2013) · Radiology · doi:10.1148/radiol.13121193 · Cited by 231
Viscoelasticity-based Staging of Hepatic Fibrosis with Multifrequency MR Elastography
Asbach, P., Klatt, D., Schlosser, B., Biermer, M., Muche, M., Rieger, A., Loddenkemper, C., Somasundaram, R., Berg, T., Hamm, B., et al. (2010) · Radiology · doi:10.1148/radiol.10092489 · Cited by 229 · cited 3×
“Pulse Sequence Various motion-sensitized MRI sequences, including gradient-recalled echo [4], spin-echo [42], echo-planar imaging [39, 43], and steadystate free precession [44], may be used to track the shear waves traversing the tissue of interest.”
Wang, Y., Ganger, D. R., Levitsky, J., Sternick, L. A., McCarthy, R. J., Chen, Z. E., Fasanati, C. W., Bolster, B., Shah, S., Zuehlsdorff, S., et al. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.4580 · Cited by 212
De Lédinghen, V., Vergniol, J., Foucher, J., El-Hajbi, F., Merrouche, W., & Rigalleau, V. (2010) · Liver International · doi:10.1111/j.1478-3231.2010.02258.x · Cited by 205 · cited 1×
“However, the performance of 1D transient elastography with the XL probe in obese subjects is controversial, with some studies reporting unreliability and failure rates as high as 23% [26, 27] and others as low as 6% [28].”
Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.15.14553 · Cited by 197 · cited 1×
“In this first article of a two-part series (see part 2 elsewhere in this issue [5]), we provide a brief overview of elastography, including a glossary of commonly used terms (Table 1), a classification of techniques, a description of the basic principles, definitions of mechanical properties, examples of ultrasound an…”
Self-citationYoon, J. H., Lee, J. M., Joo, I., Lee, E. S., Sohn, J. Y., Jang, S. K., Lee, K. B., Han, J. K., & Choi, B. I. (2014) · Radiology · doi:10.1148/radiol.14132000 · Cited by 175 · cited 1×
“Compared with transient elastography and point shear-wave elastography, shear-wave elastography has restricted product availability, and, currently, there are fewer studies on its diagnostic performance for assessment of liver fibrosis [13, 36, 37].”
Magnetic Resonance Elastography of Liver
Venkatesh, S. K., & Ehman, R. L. (2014) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2014.05.001 · Cited by 174
Quasi-Static Ultrasound Elastography
Varghese, T. (2009) · Ultrasound Clinics · doi:10.1016/j.cult.2009.10.009 · Cited by 169 · cited 1×
“, stress) [6].”
Diffraction field of a low frequency vibrator in soft tissues using transient elastography
Catheline, S., Thomas, J.-L., Wu, F., & Fink, M. A. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.775668 · Cited by 167 · cited 1×
“The mechanical impulse generates a shear wave that propagates symmetrically with respect to the axis of the single-element transducer [2, 16–20].”
Klatt, D., Asbach, P., Rump, J., Papazoglou, S., Somasundaram, R., Modrow, J., Braun, J., & Sack, I. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000244341.16372.08 · Cited by 131 · cited 1×
“Pulse Sequence Various motion-sensitized MRI sequences, including gradient-recalled echo [4], spin-echo [42], echo-planar imaging [39, 43], and steadystate free precession [44], may be used to track the shear waves traversing the tissue of interest.”
Cassinotto, C., Lapuyade, B., Aït-Ali, A., Vergniol, J., Gaye, D., Foucher, J., Bailacq‐Auder, C., Chermak, F., Bail, B. L., & de Lédinghen, V. (2013) · Radiology · doi:10.1148/radiol.13122208 · Cited by 125 · cited 1×
“Other elastography techniques also can be challenging in obesity [29].”
Friedrich‐Rust, M., Hadji-Hosseini, H., Kriener, S., Herrmann, E. M., Sircar, I., Kau, A., Zeuzem, S., & Bojunga, J. (2010) · European Radiology · doi:10.1007/s00330-010-1820-9 · Cited by 112 · cited 1×
“However, the performance of 1D transient elastography with the XL probe in obese subjects is controversial, with some studies reporting unreliability and failure rates as high as 23% [26, 27] and others as low as 6% [28].”
Naveau, S., Lamouri, K., Pourcher, G., Njiké‐Nakseu, M., Ferretti, S., Courie, R., Tranchart, H., Ghinoiu, M., Balian, A., Prevot, S., et al. (2014) · Obesity Surgery · doi:10.1007/s11695-014-1235-9 · Cited by 92 · cited 1×
“However, the performance of 1D transient elastography with the XL probe in obese subjects is controversial, with some studies reporting unreliability and failure rates as high as 23% [26, 27] and others as low as 6% [28].”
Abdominal Magnetic Resonance Elastography
Yin, M., Chen, J., Glaser, K. J., Talwalkar, J. A., & Ehman, R. L. (2009) · Topics in Magnetic Resonance Imaging · doi:10.1097/rmr.0b013e3181c4737e · Cited by 79
The role of the coupling term in transient elastography
Sandrin, L., Cassereau, D., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1635412 · Cited by 74 · cited 1×
“The mechanical impulse generates a shear wave that propagates symmetrically with respect to the axis of the single-element transducer [2, 16–20].”
Naïm, C., Cloutier, G., Mercure, E., Destrempes, F., Qin, Z., El-Abyad, W., Lanthier, S., Giroux, M.-F., & Soulez, G. (2013) · European Radiology · doi:10.1007/s00330-013-2772-7 · Cited by 61 · cited 1×
“, the heart [7] or blood vessels [8]).”
Self-citationMagnetic resonance elastography hardware design: A survey
Tse, Z. T. H., Janssen, H., Hamed, A., Ristic, M., Young, I., & Lampérth, M. U. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim529 · Cited by 51 · cited 1×
“Driver System Several driver systems have been designed to produce shear waves for MR elastography [40], including pneumatic, electromagnetic, piezoelectric, and focused ultrasound systems.”
Șirli, R., Bota, S. I., Sporea, I., Jurchis, A., Popescu, A., Gradinaru-Tascau, O., & Szilaski, M. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.03.021 · Cited by 47 · cited 1×
“Multiple ROIs then can be positioned on the elastograms, thereby reducing some of the sampling variability that can occur with 1D transient elastography and point shear-wave elastography [35].”
Wong, G. L., Vergniol, J., Lo, P., Wong, V. W., Foucher, J., Bail, B. L., Choi, P. C., Chermak, F., Leung, K.-S., Merrouche, W., et al. (2013) · Annals of Hepatology · doi:10.1016/s1665-2681(19)31341-9 · Cited by 38 · cited 2×
“Regardless, stiffness thresholds for staging liver fibrosis reported with the M probe may not be directly applicable to the XL probe [30].”
Cited by
Ultrasound Elastography: Review of Techniques and Clinical Applications
Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C., & Willmann, J. K. (2017) · Theranostics · doi:10.7150/thno.18650 · Cited by 1,877
Nonalcoholic fatty liver disease
Brunt, E. M., Wong, V. W.-S., Nobili, V., Day, C. P., Sookoian, S., Maher, J. J., Bugianesi, E., Sirlin, C. B., Neuschwander-Tetri, B. A., & Rinella, M. E. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.80 · Cited by 818
Self-citationLimitations of non-invasive tests for assessment of liver fibrosis
Patel, K., & Sebastiani, G. (2020) · JHEP Reports · doi:10.1016/j.jhepr.2020.100067 · Cited by 317
Liver fibrosis assessment: MR and US elastography
Ozturk, A., Olson, M. C., Samir, A. E., & Venkatesh, S. K. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03269-4 · Cited by 168
Deep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
Self-citation
Metadata
- Authors
- Tang, A., Cloutier, G., Szeverenyi, N. M., & Sirlin, C. B.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2015-07
- Volume
- 205
- Issue
- 1
- Pages
- 22-32
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1979482831
- Cited by
- 216
- References
- 46
- FWCI
- 13.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.