The DOI matches its Crossref record.
Detection of liver metastases with superparamagnetic iron oxide in 15 patients: results of MR imaging at 1.5 T
Abstract
The first clinical results of using superparamagnetic ferrite particles as a tissue-specific contrast agent for MR of the liver are reported at high fields (1.5 T). Fifteen patients with proved secondary liver malignancies were studied with plain and contrast-enhanced MR. Superparamagnetic iron oxide was administrated IV in a dose of 20 mumol/kg. Intermediate TR, 820/30, 60 (TR/TE), and long TR, 2200/22, 70, spin-echo sequences were used before and 1 hr after injection of contrast material. Before injection, the largest number of lesions (437) was detected with the T2-weighted sequence. Lesion-to-liver contrast, expressed as the difference between the tumor and liver signal-to-noise, improved after ferrite administration in both sequences from -1 to 20 and from 7 to 15 for the 820/30, 60 sequence and from 9 to 34 and 15 to 21 for the 2200/22, 70 sequence. Despite this significant improvement in terms of the number of lesions detected, contrast-enhanced images did not show significantly more metastases than the unenhanced T2-weighted images did (383, 421, 407, and 407 vs as many as 437, respectively). In this limited study at 1.5 T, the benefit of ferrite enhancement was only marginal when postcontrast images were compared with heavily T2-weighted precontrast scans.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Due to their high liver uptake, iron oxide nanoparticles have been employed relatively extensively for visualizing primary lesions in the liver, e.g. in case of hepatocellular carcinoma (HCC) (Figure 3 A, B) as well as liver metastases (Figure 3 C, D) [144, 145].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [144]
Citations
Cited by
Sorted by citations
Items 101–122 of 122
Magnetic Resonance Imaging of the Liver Technique
CHEZMAR, J. L. (1991) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02476-9 · Cited by 3
Kothapalli, V. S. (2013) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 3
Parameters Influencing the Efficacy of Magnetic Heating of Small Breast Tumors
Hilger, I., & Kaiser, W. A. (2011) · Else Kröner-Fresenius Symposia · doi:10.1159/000329461 · Cited by 2
Hashemzadeh, S., Akbari, M. E., Astani, S. A., et al. (2022) · NANO · doi:10.1142/s1793292022300031 · Cited by 2
Magnetic Resonance Imaging of Hepatocellular Carcinoma
Vogl, T. J., & Hammerstingl, R. (1999) · Medical radiology · doi:10.1007/978-3-642-58641-5_7 · Cited by 2
Terrier, F., Toumiaire, J., Belenger, J., Slosman, D. O., Rubbia, L., Grossholz, M., Mentha, G., Hiltbrand, E., & Mermillod, B. (1995) · Academic Radiology · doi:10.1016/s1076-6332(05)80116-3 · Cited by 2
Efficacy assessment of imaging technologies and contrast media
Högström, B. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80278-9 · Cited by 2
Hamm, B., & Taupitz, M. (1995) · Springer eBooks · doi:10.1007/978-94-011-0477-7_9 · Cited by 2
Spezielle Untersuchungsverfahren
Aichinger, H., van Gessel, R., Greis, C., et al. (2003) · Springer eBooks · doi:10.1007/978-3-642-55825-2_2 · Cited by 2
Shah, A. J., Parsons, B. A., Pope, I., et al. (2009) · Clinical Imaging · doi:10.1016/j.clinimag.2008.09.015 · Cited by 1
“The selective signal loss of healthy liver tissue that is produced by administration of SPIO particles enhances the lesion-to-liver contrast and thus improves the detection of liver metastases [3,4,6].”
BackgroundFunctionalized magnetic nanosystems in nanomedicine
Renushe, A. P., Devi, K. K., Singh, G., Sathua, K. B., Navik, U., Banothu, A. K., Bharani, K. K., & Khurana, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-19012-4.00014-x · Cited by 1
Suto, Y., & Kodama, F. (1996) · British Journal of Radiology · doi:10.1259/0007-1285-69-828-1139 · Cited by 1
Kreft, B., Block, W., Mühlhäuser, J., et al. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060219 · Cited by 1
Rathore, A. S. (2011) · Shodhganga
Leber- und Milzuntersuchungen mit superparamagnetischem Eisenoxid
Weissleder, R. (1990) · Springer eBooks · doi:10.1007/978-3-642-93460-5_4
Detection of Malignant Liver Lesions Using Different Imaging Modalities
Hamm, B. (1993) · Springer eBooks · doi:10.1007/978-3-642-77834-6_8
The Value of Magnetic Resonance Imaging in Abdominal Tumours
Langer, R. D., & FELIX, R. (1990) · Springer eBooks · doi:10.1007/978-3-642-74706-9_9
Seleem, M. I., & Salaam, M. A. (2019) · Surgical Practice · doi:10.1111/1744-1633.12393
Abstracts-part VIII (Continue in Part IX)
(1995) · Proceedings of the Society of Magnetic Resonance in Medicine · doi:10.1002/mrmp.22419950110
Recent Advances in Nanoparticles for Enhanced Molecular Diagnostics and Therapeutics
Vadlapudi, V. (2023) · International Journal of Science and Research (IJSR) · doi:10.21275/sr23807162804
“Due to their high liver uptake, iron oxide NPs have been employed relatively extensively for visualizing primary lesions in the liver, e. g. in case of hepatocellular carcinoma (HCC) as well as liver metastases [22, 23].”
BackgroundGupta, G. H., Parmar, K., Ghosh, S. K., Gupta, S., Aherwar, V., Kadam, S., Thakkellapati, S., Choppadandi, M., Rao, K. S., Babu, S. S., et al. (2025) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2025.115372 · Cited by 1
Halavaara, J. T. (2002) · Työväentutkimus Vuosikirja
Metadata
- Authors
- Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E.
- Affiliations
- KU Leuven (BE)
- Department of Radiology, University Hospitals, K.U. Leuven, Belgium.
- ORCID
- Demaerel, P
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1989-04-01
- Volume
- 152
- Issue
- 4
- Pages
- 771-775
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1963756164
- Cited by
- 122
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 1 · 2019: 3 · 2017: 1 · 2014: 2 · 2013: 4
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- liver metastasis, superparamagnetic iron oxide nanoparticles, MRI contrast agents, ferrite particles, contrast-enhanced MRI, T2-weighted imaging, lesion detection, 1.5T MRI
- MeSH terms
- Aged, Female, Ferric Compounds, Humans, Injections, Intravenous, Liver Neoplasms, Magnetic Resonance Imaging, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review