The effect of high- vs low-density barium preparations on the quantitative features of swallowing
The DOI matches its Crossref record.
Abstract
We compared the effect of high-density and low-density barium preparations on the quantitative features of swallowing. The two barium preparations differed primarily in density but also differed somewhat in viscosity. Concurrent videofluoroscopic and manometric studies were done in nine healthy control subjects. Videofluoroscopy was recorded in the lateral projection at 30 frames/sec while concurrent manometry was done with five intraluminal transducers that straddled the pharynx and upper esophageal sphincter. Swallows of 5 and 10 ml of high- and low-density barium preparations were recorded. Analysis indicated that, compared with the low-density barium (1.4 g/cm3), the high-density barium (2.5 g/cm3) preparation had a slower oral and pharyngeal bolus transit time and caused significant quantitative differences in the function of the upper esophageal sphincter. Compared with low-density barium boluses, the high-density barium boluses were associated with later sphincter opening and closure, longer duration of sphincter opening and flow, lower flow rate, greater maximal anterior hyoid movement, greater sagittal sphincter diameter, and higher intrabolus pressure upstream of and within the sphincter. We conclude that the density as well as the viscosity of the barium preparation used in radiologic examination of the oral-pharyngeal phases of swallowing has an influence on bolus transit time through the mouth and pharynx, and on the quantitative features of upper esophageal sphincter opening. Although these quantitative differences cannot generally be recognized visually at fluoroscopy, they become important for the quantitative assessment of swallowing in patients with suspected disorders of oral-pharyngeal swallowing. Therefore, the basic barium preparations used to examine such patients should be either standardized or at least specified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiology and radiology of the normal oral and pharyngeal phases of swallowing.
Dodds, W. J., Stewart, E. T., & Logemann, J. A. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.154.5.2108569 · Cited by 569
Self-citationThe Effects of Lingual Exercise in Stroke Patients With Dysphagia
Robbins, J., Kays, S. A., Gangnon, R. E., Hind, J. A., Hewitt, A. L., Gentry, L. R., & Taylor, A. J. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2006.11.002 · Cited by 523
Effects of bolus volume, viscosity, and repeated swallows in nonstroke subjects and stroke patients
Lazarus, C. L., Logemann, J. A., Rademaker, A. W., Kahrilas, P. J., Pajak, T., Lazar, R., & Halper, A. (1993) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(93)90063-g · Cited by 242
Hyoid Motion During Swallowing: Factors Affecting Forward and Upward Displacement
Ishida, R., Palmer, J. B., & Hiiemae, K. M. (2002) · Dysphagia · doi:10.1007/s00455-002-0064-5 · Cited by 240
Reference values for healthy swallowing across the range from thin to extremely thick liquids
Steele, C. M., Peladeau-Pigeon, M., Barbon, C. A. E., Guida, B. T., Namasivayam-MacDonald, A. M., Nascimento, W. V., Smaoui, S., Tapson, M. S., Valenzano, T. J., Waito, A. A., et al. (2019) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2019_jslhr-s-18-0448 · Cited by 180
“…from a cup containing 40 ml of liquid (as opposed to delivering boluses of fixed volume); • the absence of verbal cues (Daniels et al., 2007; Nagy et al., 2013); and • use of a 20% w/v barium concentration (Dantas et al., 1989; Humbert et al., 2018; Steele et al., 2013; Stokely et al., 2014).”
BackgroundViscosity effects on EMG activity in normal swallow
Reimers-Neils, L., Logemann, J., & Larson, C. (1994) · Dysphagia · doi:10.1007/bf00714596 · Cited by 180
“cies. Most of these previous investigations have utilized radiographic imaging, manometry, and/or endoscopy [ 2-7 ].”
BackgroundMiller, J. L., & Watkin, K. L. (1996) · Dysphagia · doi:10.1007/bf00417901 · Cited by 165
Best practices in modified barium swallow studies
Martin-Harris, B., Canon, C. L., Bonilha, H. S., Murray, J., Davidson, K., & Lefton-Greif, M. A. (2020) · American Journal of Speech-Language Pathology · doi:10.1044/2020_ajslp-19-00189 · Cited by 129
“…Best Practices in Modified Barium Swallow Studies 1079 Barium sulfate suspension is the contrast agent used in boluses of thin and thick liquids, semisolids, and solids to allow visualization of liquids and foods simulating those on a patient’s meal tray (Dantas et al., 1989; Robbins et al., 2002).”
Background
Metadata
- Authors
- Dantas, R., Dodds, W., Massey, B., & Kern, M.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1989-12-01
- Volume
- 153
- Issue
- 6
- Pages
- 1191-1195
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1996347136
- Cited by
- 122
- References
- 0
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.