Detection of ACTH-producing bronchial carcinoid tumors: MR imaging vs CT.
The DOI matches its Crossref record.
Abstract
Adrenocorticotrophic hormone (ACTH)-producing bronchial carcinoid tumors tend to occur in the middle third of the lung adjacent to pulmonary vessels. Because they cause signs and symptoms when quite small (by virtue of their ACTH production), they may not be detected by CT. MR imaging was performed in 10 consecutive patients with surgically proved ACTH-producing bronchial carcinoid tumors in order to test the ability of MR to clarify equivocal or indeterminate findings on CT examinations. All bronchial carcinoid tumors had high signal intensity on T2-weighted and short-inversion-time inversion-recovery images, facilitating their distinction from pulmonary vasculature. In eight patients, the CT and MR images were equivalent in the detection of bronchial carcinoid tumors. In two patients, MR showed tumors in the middle third of the lung that were equivocal on CT. MR imaging may distinguish small bronchial carcinoid tumors from adjacent pulmonary vessels in the central third of the lung at a time when the CT study is nondiagnostic or equivocal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lacroix, A., Feelders, R. A., Stratakis, C. A., & Nieman, L. K. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61375-1 · Cited by 1,777
Self-citationThe Diagnosis and Differential Diagnosis of Cushing’s Syndrome and Pseudo-Cushing’s States
Newell-Price, J., Trainer, P., Besser, M., & Grossman, A. (1998) · Endocrine Reviews · doi:10.1210/edrv.19.5.0346 · Cited by 833
“MRI seems to be an improvement over CT for this purpose and results in improved discrimination: scanning in 10 patients with surgically proven bronchial carcinoid tumors demonstrated high signal intensity on T2-weighted and short-inversion-time inversion recovery images in all, while CT scanning was equivocal in two (…”
BackgroundIlias, I., Torpy, D. J., Pacak, K., Mullen, N., Wesley, R. A., & Nieman, L. K. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-2527 · Cited by 713
Self-citationCushing’s Syndrome: important issues in diagnosis and management
Findling, J. W., & Raff, H. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0997 · Cited by 294
Self-citationImaging of neuroendocrine tumours (CT/MR/US)
Rockall, A. G., & Reznek, R. H. (2007) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2007.01.003 · Cited by 216
Metadata
- Authors
- Doppman, J. L., Pass, H. I., Nieman, L. K., Findling, J. W., Dwyer, A. J., Feuerstein, I. M., Ling, A., Travis, W. D., Cutler, G. B., & Chrousos, G. P.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1991-01
- Volume
- 156
- Issue
- 1
- Pages
- 39-43
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2071452065
- Cited by
- 84
- References
- 0
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of ACTH-producing bronchial carcinoid tumors: MR imaging vs CT. https://app.cochat.ai/papers/10.2214/ajr.156.1.1845787
- The paper
- Doppman, J. L., Pass, H. I., Nieman, L. K., Findling, J. W., Dwyer, A. J., Feuerstein, I. M., Ling, A., Travis, W. D., Cutler, G. B., & Chrousos, G. P. (1991). Detection of ACTH-producing bronchial carcinoid tumors: MR imaging vs CT. American Journal of Roentgenology. https://doi.org/10.2214/ajr.156.1.1845787
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.