The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sonography of the shoulder in patients with tears of the rotator cuff: accuracy and value for selecting surgical options.
Abstract
OBJECTIVE: The management of patients with signs and symptoms referable to the rotator cuff depends on the presence of cuff injury and the size of the tear. Treatment options include conservative nonsurgical management for patients with an intact or partially torn cuff, arthroscopic decompression of the coracoacromial space for those not responding to nonsurgical management, and a range of surgical techniques to repair full-thickness tears. This study was designed to determine whether sonographic evaluation with classification of the extent of cuff injury is accurate for purposes of treatment planning. SUBJECTS AND METHODS: Preoperative sonography of the rotator cuff was performed on 225 patients, and findings were classified into intact, partial tear, small full-thickness tear, large full-thickness tear, and massive tear groups. Surgical correlation with the predicted sonographic classification was provided by arthroscopic inspection or open surgery. RESULTS: The sonographic findings were surgically confirmed for 206 (92%) of the 225 patients. More extensive cuff injury was encountered during surgery than had been predicted sonographically in 11 patients (5%); less extensive injury than predicted was found during surgery in eight patients (4%). CONCLUSION: Our results show a high correlation between the sonographic classification of rotator cuff injury and the surgical findings. The selection of appropriate treatment programs can be reliably based on the sonographic classification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and Treatment of Incomplete Rotator Cuff Tears
ELLMAN, H. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199005000-00010 · Cited by 678
Cited by
de Jesus, J. O., Parker, L., Frangos, A. J., & Nazarian, L. N. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1241 · Cited by 608
TEEFEY, S. A., RUBIN, D. A., MIDDLETON, W. D., HILDEBOLT, C. F., LEIBOLD, R. A., & YAMAGUCHI, K. (2004) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200404000-00007 · Cited by 476
Mechanisms of rotator cuff tendinopathy: Intrinsic, extrinsic, or both?
Seitz, A. L., McClure, P. W., Finucane, S., Boardman, N. D., & Michener, L. A. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.08.001 · Cited by 474
Roy, J.-S., Braën, C., Leblond, J., Desmeules, F., Dionne, C. E., MacDermid, J. C., Bureau, N. J., & Frémont, P. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-094148 · Cited by 319
Lenza, M., Buchbinder, R., Takwoingi, Y., Johnston, R. V., Hanchard, N. C., & Faloppa, F. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009020.pub2 · Cited by 267
Metadata
- Authors
- Wiener, S. N., & Seitz, W. H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1993-01
- Volume
- 160
- Issue
- 1
- Pages
- 103-107
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2024251533
- Cited by
- 236
- References
- 1
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sonography of the shoulder in patients with tears of the rotator cuff: accuracy and value for selecting surgical options. https://app.cochat.ai/papers/10.2214/ajr.160.1.8416605
- The paper
- Wiener, S. N., & Seitz, W. H. (1993). Sonography of the shoulder in patients with tears of the rotator cuff: accuracy and value for selecting surgical options. American Journal of Roentgenology. https://doi.org/10.2214/ajr.160.1.8416605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.