Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record.

Distinction between benign and malignant adrenal masses: value of T1-weighted chemical-shift MR imaging.

Outwater, E K, Siegelman, E S, Radecki, P D, Piccoli, C W, Mitchell, D G · 1995 · American Journal of Roentgenology

Abstract

OBJECTIVE: Accuracy of T1-weighted chemical-shift MR imaging for the differentiation between benign and malignant adrenal masses was blindly assessed among three radiologists. SUBJECTS AND METHODS: MR imaging was performed at 1.5 T in 50 patients with 58 adrenal masses, proved benign (n = 38) or malignant (n = 20) based on surgery or growth (malignant) or stable size (benign) for at least 1 year. In-phase spin-echo sequences or in-phase breath-hold fast multiplanar spoiled gradient-recalled echo (FMPSPGR) sequences with a TE of 4.2 msec were compared with opposed-phase breath-hold FMPSPGR sequences with a TR/TE of 35-155/2.2-2.9 and a 90 degrees flip angle for the detection of lipid in adrenal masses. Three radiologists who were blinded to diagnosis and clinical data independently rated the likelihood of a benign adrenal lesion on a five-point scale of confidence. RESULTS: Mean sensitivity, specificity, and positive predictive value for a definite or probable diagnosis of a benign lesion by the three readers were 87%, 92%, and 95%, respectively. At the highest (definite) confidence of a benign lesion, the mean positive predictive value was 99%, with lower sensitivity (54%). Areas under receiver operating characteristic curves for the three radiologists were .98 (95% confidence interval [CI] = .94-1.00), .96 (CI = .91-1.00), and .95 (CI = .89-1.00). Interobserver variation for the diagnosis of a benign mass was low (kappa = .79). CONCLUSION: Chemical-shift imaging using breath-hold opposed-phase T1-weighted MR images is a reliable and reproducible technique for the diagnosis of most benign adrenal masses at the highest threshold of confidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.165.3.7645474

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Outwater, E. K., Siegelman, E. S., Radecki, P. D., Piccoli, C. W., & Mitchell, D. G.
Venue
American Journal of Roentgenology
Published
1995-09
Volume
165
Issue
3
Pages
579-583
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W1995700748
Cited by
185
References
0
FWCI
6.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distinction between benign and malignant adrenal masses: value of T1-weighted chemical-shift MR imaging. https://app.cochat.ai/papers/10.2214/ajr.165.3.7645474
The paper
Outwater, E. K., Siegelman, E. S., Radecki, P. D., Piccoli, C. W., & Mitchell, D. G. (1995). Distinction between benign and malignant adrenal masses: value of T1-weighted chemical-shift MR imaging. American Journal of Roentgenology. https://doi.org/10.2214/ajr.165.3.7645474

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.