Quantification of pneumothorax size on chest radiographs using interpleural distances: regression analysis based on volume measurements from helical CT.
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The aim of this study was to define the relationship between interpleural distance measurements on an erect posteroanterior chest radiograph and pneumothorax size as measured by helical CT in a series of patients. SUBJECTS AND METHODS: Twenty pneumothoraces from 19 patients (10 males, nine females) were analyzed. Most pneumothoraces were on the right side (n = 16). The etiology was spontaneous in seven patients and iatrogenic in thirteen. All patients underwent an erect inspiratory posteroanterior radiograph and a helical CT scan of the thorax on the same visit to the radiology department. The interpleural distance was measured at three locations and the figures added together. Following helical CT of the thorax, the percentage pneumothorax size was calculated by drawing regions of interest around the relevant hemithorax and lung on 10-mm reconstructed slices. A scattergram of the sum of interpleural distances in centimeters versus percentage pneumothorax size was plotted. RESULTS: Analysis of results showed that percentage pneumothorax size could be calculated by the formula Y = 4.2 + [4.7 x (A + B + C)], r = .98, p < .0001. CONCLUSION: This study identified a formula for accurately calculating percentage pneumothorax size as determined by helical CT from an erect posteroanterior radiograph. Using this formula with the clinical status of the patient should more easily identify patients requiring active intervention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, A. C., & Harvey, J. E. (1993) · BMJ · doi:10.1136/bmj.307.6896.114 · Cited by 173
SPONTANEOUS PNEUMOTHORAX AND ITS TREATMENT
Kircher, L. T. (1954) · JAMA · doi:10.1001/jama.1954.03690190030009 · Cited by 156 · cited 3×
“Alterations in lung and chest cavity volume following change in posture have been described [9-1 3].”
BackgroundMethodBlair, E., & Hickam, J. B. (1955) · Journal of Clinical Investigation · doi:10.1172/jci103086 · Cited by 142
Chest Radiograph—A Poor Method for Determining the Size of a Pneumothorax
Engdahl, O., Toft, T., & Boe, J. (1993) · CHEST Journal · doi:10.1378/chest.103.1.26 · Cited by 79 · cited 2×
“Previous studies of CT measurements of pencentage pneumothonax size [5, 6] have used only contiguous sections.”
BackgroundMethod
Cited by
BTS guidelines for the management of spontaneous pneumothorax
Henry, M., Arnold, T., Harvey, J., & on behalf of the BTS Pleural Disease Group, A. S. O. T. B. S. O. C. C. (2003) · Thorax · doi:10.1136/thx.58.suppl_2.ii39 · Cited by 631
Conservative versus Interventional Treatment for Spontaneous Pneumothorax
Brown, S. G. A., Ball, E. L., Perrin, K., Asha, S. E., Braithwaite, I., Egerton-Warburton, D., Jones, P. G., Keijzers, G., Kinnear, F. B., Kwan, B. C. H., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910775 · Cited by 270
Kelly, A.-M., & Druda, D. (2008) · Respiratory Medicine · doi:10.1016/j.rmed.2008.07.026 · Cited by 58
Metadata
- Authors
- Collins, C. D., Lopez, A., Mathie, A., Wood, V, Jackson, J. E., & Roddie, M. E.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1995-11
- Volume
- 165
- Issue
- 5
- Pages
- 1127-1130
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2149166368
- Cited by
- 204
- References
- 4
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.