Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 197

The DOI matches its Crossref record.

Screening mammography in community practice: positive predictive value of abnormal findings and yield of follow-up diagnostic procedures.

Brown, M L, Houn, F, Sickles, E A, Kessler, L G · 1995 · American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to gather from 50 community mammography practices that were included in the National Survey of Mammography Facilities data concerning abnormal findings on screening mammograms to determine the frequency of various recommendations made for patients who had abnormal findings and to compare these recommendations with the frequency with which the procedures were actually performed. We also determined the positive predictive value of screening mammograms (the number of cancers detected per 100 abnormal findings) and the yield (the number of cancers detected per 100 procedures done) of various diagnostic procedures done because of abnormal findings. MATERIALS AND METHODS: We identified 1717 screening mammograms done in the last half of 1991 that had abnormal findings. Radiologic recommendations and follow-up procedures, including repeat standard (screening) mammography, additional mammographic views, sonography, clinical breast examination, needle aspiration, needle biopsy, and open biopsy, were identified for all of the cases from the radiologic records, and follow-up data were obtained from referring physicians. The positive predictive value and yield in the National Survey of Mammography Facilities were compared with data from the mammography screening practice of the University of California at San Francisco (UCSF), a facility noted for its clinical efficiency. RESULTS: We estimate that 11% of all screening mammograms resulted in a recommendation for further diagnostic procedures. These 1717 mammograms with abnormal findings led to the following recommendations and procedures: repeat standard (screening) mammography, 610 (recommended)/635 (performed); additional mammographic views, 785/707; sonography, 400/345; biopsy, 189/229; and needle aspiration, 21/51. More procedures were done than were recommended in some cases because the results of certain procedures often led to the performance of other, additional procedures. The positive predictive value for screening examinations with abnormal findings was 3.5%, and the yield for open biopsy was 21%. In the UCSF data base, the positive predictive value for examinations with abnormal findings was 10%, and the yield for open biopsy was 34%. CONCLUSION: The positive predictive value for examinations with abnormal findings and the yield for diagnostic procedures performed as a result of abnormal findings in 50 community radiologic facilities were higher than those reported in some earlier studies, a fact that raised concern about the induced cost of screening mammography. However, these values were low compared with those in the UCSF data base. This fact was particularly true of repeat standard (screening) mammography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.165.6.7484568

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 197

Metadata

Authors
Brown, M. L., Houn, F., Sickles, E. A., & Kessler, L. G.
Venue
American Journal of Roentgenology
Published
1995-12
Volume
165
Issue
6
Pages
1373-1377
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2009276120
Cited by
197
References
0
FWCI
7.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Screening mammography in community practice: positive predictive value of abnormal findings and yield of follow-up diagnostic procedures. https://app.cochat.ai/papers/10.2214/ajr.165.6.7484568
The paper
Brown, M. L., Houn, F., Sickles, E. A., & Kessler, L. G. (1995). Screening mammography in community practice: positive predictive value of abnormal findings and yield of follow-up diagnostic procedures. American Journal of Roentgenology. https://doi.org/10.2214/ajr.165.6.7484568

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.