Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries.

Holland, G A, Dougherty, L, Carpenter, J P, Golden, M A, Gilfeather, M, Slossman, F, Schnall, M D, Axel, L·1996·American Journal of Roentgenology

Abstract

OBJECTIVES: The objectives of this study were to develop and show the efficacy of a breath-hold ultrafast three-dimensional (3D) spoiled gradient-echo (SPGR) gadolinium-enhanced MR angiographic technique for imaging the aorta and the renal and other visceral arteries of the abdomen; and to compare breath-hold ultrafast 3D SPGR with two-dimensional (2D) time-of-flight (TOF) and non-breath-hold ultrafast 3D SPGR in the same patients. SUBJECTS AND METHODS: We prospectively studied the abdominal aorta and the renal and other visceral arteries 68 times in 63 consecutive patients with 2D TOF and ultrafast 3D SPGR MR angiography. Thirty-two patients had contrast angiography (n = 23) and/or surgery (n = 24) to serve as a gold standard. All MR imaging studies were performed on a 1.5-T scanner (General Electric Medical Systems, Milwaukee, WI) using an enhanced gradient system with maximum gradient strength of 2.3 gauss/cm reached in 150 microseconds. Axial 2D TOF parameters were: TR/TE, 33/5.5 msec; flip angle, 45 degrees; slice thickness, 2 mm; and no presaturation pulses. Coronal ultrafast 3D SPGR was performed before and after the i.v. administration of 40-60 cc of gadolinium. For the coronal ultrafast 3D SPGR, our parameters were: TR/TE, 4.8-7/1.1; flip angle, 60 degrees; 28-50 slices of 2.0-2.6 mm thickness; and acquisition time, 18-32 sec. Studies were read by a single radiologist [corrected] and were evaluated for the degree of stenosis in the renal, celiac, superior mesenteric, and inferior mesenteric arteries; any vascular anomalies (i.e., retroaortic renal veins and accessory renal or variant hepatic arteries) were noted. RESULTS: Breath-hold ultrafast 3D SPGR correctly identified 31 of 31 stenoses of the renal artery for a sensitivity, specificity, and accuracy of 100%. Two-dimensional TOF detected 23 of 31 renal artery stenoses for a sensitivity, specificity, and accuracy of 74%, 98%, and 87% respectively. Breath-hold ultrafast 3D SPGR underestimated two renal arteries as having severe osteal stenoses that were graded correctly by 2D TOF and by angiography as occlusions. Eight of nine (89%) accessory renal arteries were correctly identified with breath-hold ultrafast 3D SPGR: Two-dimensional TOF identified six of nine (67%). Breath-hold ultrafast 3D SPGR identified one accessory and two reconstituted renal arteries missed by 2D TOF and conventional contrast angiography that were confirmed at surgery. Ultrafast 3D SPGR and 2D TOF correctly identified 20 of 20 celiac, superior mesenteric, and inferior mesenteric artery osteal stenoses or occlusions for a sensitivity, specificity, and accuracy of 100%. Three Riolan's arcs were correctly identified by breath-hold 3D SPGR but were missed by 2D TOF: Forty of the 63 patients did not have conventional contrast angiography and were managed surgically (n = 9) or medically (n = 31) based on the results of the MR angiograms and clinical data. Breath-hold ultrafast 3D SPGR MR angiography correctly identified and graded 48 of 51 renal, celiac, superior mesenteric, and inferior mesenteric artery stenoses or occlusions. Two-dimensional TOF MR angiography correctly identified and graded 45 of 51 renal, celiac, superior mesenteric, and inferior mesenteric artery stenoses and occlusions. CONCLUSION: Breath-hold ultrafast 3D SPGR when combined with 2D TOF accurately identified and graded all (51 of 51) renal, celiac, superior mesenteric, and inferior mesenteric artery stenoses or occlusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.166.4.8610584

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Holland, G. A., Dougherty, L., Carpenter, J. P., Golden, M. A., Gilfeather, M., Slossman, F., Schnall, M. D., & Axel, L.
Venue
American Journal of Roentgenology
Published
1996-04
Volume
166
Issue
4
Pages
971-981
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2001784133
Cited by
232
References
0
FWCI
38.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries. https://app.cochat.ai/papers/10.2214/ajr.166.4.8610584
The paper
Holland, G. A., Dougherty, L., Carpenter, J. P., Golden, M. A., Gilfeather, M., Slossman, F., Schnall, M. D., & Axel, L. (1996). Breath-hold ultrafast three-dimensional gadolinium-enhanced MR angiography of the aorta and the renal and other visceral abdominal arteries. American Journal of Roentgenology. https://doi.org/10.2214/ajr.166.4.8610584

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.