Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography.
The DOI matches its Crossref record.
Abstract
OBJECTIVE: MR coronary angiography is most often performed using two-dimensional techniques. Although three-dimensional (3D) acquisitions do have important advantages, they take too long for a single breath-hold and are thus susceptible to respiratory motion artifacts. The purpose of this study was to investigate the accuracy of a unique respiratory-gated 3D MR angiographic technique in identifying the proximal coronary arteries in patients suspected of having coronary artery disease. In addition, we investigated the capability of this technique to detect proximal stenoses. SUBJECTS AND METHODS: We performed a prospective blinded study in 20 patients who were referred for conventional coronary angiography. A cardiac-gated 3D gradient-echo sequence with fat suppression was used. Retrospective respiratory gating was performed using navigator echoes of the diaphragm position. Using multiplanar reformatting, two independent readers blindly analyzed the data sets for visualization of major coronary arteries, lengths of imaged segments, and detection of significant stenoses (> 50% occlusion of the luminal diameter by conventional angiography). RESULTS: Seventy-seven of 80 (96%) coronary arteries were positively identified. In one patient, an anomalous coronary anatomy was readily identified and confirmed by conventional angiography. The average lengths of the imaged segments of the right, left main, left anterior descending, and left circumflex coronary arteries were 58 +/- 13 mm, 9 +/- 5 mm, 59 +/- 16 mm, and 24 +/- 10 mm, respectively. Overall sensitivity for the detection of stenoses was low (38%), with a specificity of 95%. Interobserver agreement was 0.92, with a kappa value of 0.65. CONCLUSION: Respiratory-gated 3D MR angiography allows accurate identification of proximal coronary arteries and may be valuable for 3D imaging of coronary anomalies. Further technical improvements are required to enhance the value of the technique in detecting stenoses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coronary angiography with multi-slice computed tomography
Nieman, K., Oudkerk, M., Rensing, B. J., van Ooijen, P., Munne, A., van Geuns, R.-J., & de Feyter, P. J. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04058-7 · Cited by 725
Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Fayad, Z. A., Fuster, V., Nikolaou, K., & Becker, C. (2002) · Circulation · doi:10.1161/01.cir.0000034392.34211.fc · Cited by 276
Stuber, M., Botnar, R. M., Danias, P. G., Kissinger, K. V., & Manning, W. J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99au50579 · Cited by 256
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Metadata
- Authors
- Post, J. C., van Rossum, A. C., Hofman, M. B., Valk, J., & Visser, C. A.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1996-06
- Volume
- 166
- Issue
- 6
- Pages
- 1399-1404
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2133571450
- Cited by
- 176
- References
- 0
- FWCI
- 18.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography. https://app.cochat.ai/papers/10.2214/ajr.166.6.8633453
- The paper
- Post, J. C., van Rossum, A. C., Hofman, M. B., Valk, J., & Visser, C. A. (1996). Three-dimensional respiratory-gated MR angiography of coronary arteries: comparison with conventional coronary angiography. American Journal of Roentgenology. https://doi.org/10.2214/ajr.166.6.8633453
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.