The DOI matches its Crossref record.
Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing.
Abstract
OBJECTIVE: Helical CT scanners allow multiple-phase sequential scans of the entire liver to be obtained during a single bolus injection of contrast material. The purpose of this study was to compare two injection protocols and to establish timing that would optimize detection of hepatomas less than 3 cm in diameter. SUBJECTS AND METHODS: Triple-phase helical CT of the liver was evaluated in 217 patients who had liver cirrhosis and were referred for known or suspected hepatomas. Proof of individual neoplasms was based on biopsy results, surgical findings, or findings of other imaging studies. Sixty percent nonionic contrast material, infused at 2 or 4 ml/sec, was followed by sequential arterial-phase, portal-venous phase, and equilibrium-phase helical scans of the liver. Aortic and hepatic enhancement curves were constructed by measuring CT attenuation. The CT attenuation values of individual tumor lesions were also measured. We compared the degree of enhancement of normal structures and tumors obtained with four scan protocols (injection at 2 ml/sec with a 30-sec scan delay [n = 54], injection at 2 ml/sec with a 35-sec scan delay [n = 47], injection at 4 ml/sec with a 20-sec scan delay [n = 56], and injection at 4 ml/sec with a 25-sec scan delay [n = 60] and determined the optimal injection protocol and timing for CT acquisition. RESULTS: Peak aortic and hepatic enhancement was obtained earlier with the 4-ml/sec protocol (at 24 sec and 61 sec versus 36 sec and 90 sec for the 2-ml/sec protocol). The peak attenuation value of the aorta was higher with the 4-ml/sec protocol (330 H versus 186 H for the 2-ml/sec protocol). However, peak hepatic attenuation was similar for both protocols (98 H for the 4-ml/sec protocol versus 92 H for the 2-ml/sec protocol). Liver-tumor contrast was highest in the arterial phase with both protocols. The next highest contrast was obtained during the equilibrium phase. Liver-tumor contrast in the portal-venous phase was significantly lower than that in the other two phases. Tumor enhancement was significantly higher in scans obtained using the 4-ml/sec protocol with a delay time of 25 sec than those obtained with a delay time of 20 sec. In 109 hepatomas, 35 tumors were only seen or were most conspicuous during the arterial phase, four tumors were most conspicuous during the equilibrium phase, and one tumor was most conspicuous during the portal-venous phase. CONCLUSION: Arterial-phase helical CT of the liver after 4-ml/sec injection of contrast material significantly improves detection of hepatomas less than 3 cm in diameter when performed in addition to delayed scanning. Portal-venous phase helical CT is of limited value in detecting small hepatomas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging for the diagnosis of hepatocellular carcinoma: A systematic review and meta‐analysis
Roberts, L. R., Sirlin, C. B., Zaiem, F., Almasri, J., Prokop, L. J., Heimbach, J. K., Murad, M. H., & Mohammed, K. (2018) · Hepatology · doi:10.1002/hep.29487 · Cited by 497
Liver-specific agents for contrast-enhanced MRI: role in oncological imaging
Thian, Y. L., Riddell, A. M., & Koh, D.-M. (2013) · Cancer Imaging · doi:10.1102/1470-7330.2013.0050 · Cited by 64
Metadata
- Authors
- Mitsuzaki, K., Yamashita, Y., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1996-09
- Volume
- 167
- Issue
- 3
- Pages
- 753-757
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2120133732
- Cited by
- 160
- References
- 0
- FWCI
- 3.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. https://app.cochat.ai/papers/10.2214/ajr.167.3.8751695
- The paper
- Mitsuzaki, K., Yamashita, Y., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996). Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. American Journal of Roentgenology. https://doi.org/10.2214/ajr.167.3.8751695
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.