Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record.

Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing.

Mitsuzaki, K, Yamashita, Y, Ogata, I, Nishiharu, T, Urata, J, Takahashi, M·1996·American Journal of Roentgenology

Abstract

OBJECTIVE: Helical CT scanners allow multiple-phase sequential scans of the entire liver to be obtained during a single bolus injection of contrast material. The purpose of this study was to compare two injection protocols and to establish timing that would optimize detection of hepatomas less than 3 cm in diameter. SUBJECTS AND METHODS: Triple-phase helical CT of the liver was evaluated in 217 patients who had liver cirrhosis and were referred for known or suspected hepatomas. Proof of individual neoplasms was based on biopsy results, surgical findings, or findings of other imaging studies. Sixty percent nonionic contrast material, infused at 2 or 4 ml/sec, was followed by sequential arterial-phase, portal-venous phase, and equilibrium-phase helical scans of the liver. Aortic and hepatic enhancement curves were constructed by measuring CT attenuation. The CT attenuation values of individual tumor lesions were also measured. We compared the degree of enhancement of normal structures and tumors obtained with four scan protocols (injection at 2 ml/sec with a 30-sec scan delay [n = 54], injection at 2 ml/sec with a 35-sec scan delay [n = 47], injection at 4 ml/sec with a 20-sec scan delay [n = 56], and injection at 4 ml/sec with a 25-sec scan delay [n = 60] and determined the optimal injection protocol and timing for CT acquisition. RESULTS: Peak aortic and hepatic enhancement was obtained earlier with the 4-ml/sec protocol (at 24 sec and 61 sec versus 36 sec and 90 sec for the 2-ml/sec protocol). The peak attenuation value of the aorta was higher with the 4-ml/sec protocol (330 H versus 186 H for the 2-ml/sec protocol). However, peak hepatic attenuation was similar for both protocols (98 H for the 4-ml/sec protocol versus 92 H for the 2-ml/sec protocol). Liver-tumor contrast was highest in the arterial phase with both protocols. The next highest contrast was obtained during the equilibrium phase. Liver-tumor contrast in the portal-venous phase was significantly lower than that in the other two phases. Tumor enhancement was significantly higher in scans obtained using the 4-ml/sec protocol with a delay time of 25 sec than those obtained with a delay time of 20 sec. In 109 hepatomas, 35 tumors were only seen or were most conspicuous during the arterial phase, four tumors were most conspicuous during the equilibrium phase, and one tumor was most conspicuous during the portal-venous phase. CONCLUSION: Arterial-phase helical CT of the liver after 4-ml/sec injection of contrast material significantly improves detection of hepatomas less than 3 cm in diameter when performed in addition to delayed scanning. Portal-venous phase helical CT is of limited value in detecting small hepatomas.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.167.3.8751695

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Mitsuzaki, K., Yamashita, Y., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M.
Venue
American Journal of Roentgenology
Published
1996-09
Volume
167
Issue
3
Pages
753-757
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2120133732
Cited by
160
References
0
FWCI
3.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. https://app.cochat.ai/papers/10.2214/ajr.167.3.8751695
The paper
Mitsuzaki, K., Yamashita, Y., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996). Multiple-phase helical CT of the liver for detecting small hepatomas in patients with liver cirrhosis: contrast-injection protocol and optimal timing. American Journal of Roentgenology. https://doi.org/10.2214/ajr.167.3.8751695

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.