Adverse reactions to gadolinium contrast media: a review of 36 cases.
Open accessAbstract
OBJECTIVE: We investigated the frequency, manifestations, and severity of reactions to gadolinium contrast media in patients who underwent MR imaging at a single institution. MATERIALS AND METHODS: We reviewed the quality assurance records of 21,000 patients to whom gadolinium contrast media were administered at our institution between January 1990 and October 1994. Of these patients, 36 had adverse reactions. All 36 patients were evaluated by a radiologist at the time of the adverse reaction, and a written report of the findings was completed immediately. RESULTS: We classified adverse reactions into four groups: mild nonallergic reactions (15 patients with nausea or vomiting), mild reactions resembling allergy (12 patients with hives, diffuse erythema, or skin irritation), moderate reactions resembling allergy (seven patients with respiratory symptoms), and life-threatening reactions resembling allergy (two patients with severe chest tightness, respiratory distress, and periorbital edema). Eleven of these 36 patients who had adverse reactions also had an unusual local reaction of skin discomfort in the extremity through which gadolinium was injected. Four of the 36 patients with adverse reactions had histories of adverse reactions to iodinated contrast media. All four of these patients and one of the remaining 32 patients with adverse reactions required treatment. No patients with adverse reactions died. CONCLUSION: Although gadolinium contrast media are safe, we found that patients had adverse reactions at a frequency greater than we expected. Severe anaphylactoid reactions occurred in two patients (0.01%). This rate exceeds the rate of 0.0003% reported in the literature. The indexes of suspicion for the occurrence of reactions to gadolinium, and both the documentation and the management of adverse reactions, must be as rigorous for reactions associated with MR imaging contrast agents as they are for reactions associated with iodinated contrast media.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Single-breath-hold photoacoustic computed tomography of the breast
Lin, L., Hu, P., Shi, J., Appleton, C. M., Maslov, K., Li, L., Zhang, R., & Wang, L. V. (2018) · Nature Communications · doi:10.1038/s41467-018-04576-z · Cited by 454
Idée, J., Port, M., Raynal, I., Schaefer, M., Le Greneur, S., & Corot, C. (2006) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2006.00447.x · Cited by 395
Trends in Adverse Events After IV Administration of Contrast Media
Cochran, S. T., Bomyea, K., & Sayre, J. W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.6.1761385 · Cited by 358
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Dillman, J. R., Ellis, J. H., Cohan, R. H., Strouse, P. J., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2554 · Cited by 303
Self-citation
Metadata
- Authors
- Murphy, K. J., Brunberg, J. A., & Cohan, R. H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1996-10
- Volume
- 167
- Issue
- 4
- Pages
- 847-849
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2046394326
- Cited by
- 276
- References
- 0
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adverse reactions to gadolinium contrast media: a review of 36 cases. https://app.cochat.ai/papers/10.2214/ajr.167.4.8819369
- The paper
- Murphy, K. J., Brunberg, J. A., & Cohan, R. H. (1996). Adverse reactions to gadolinium contrast media: a review of 36 cases. American Journal of Roentgenology. https://doi.org/10.2214/ajr.167.4.8819369