The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Single-breath-hold photoacoustic computed tomography of the breast
Open accessAbstract
We have developed a single-breath-hold photoacoustic computed tomography (SBH-PACT) system to reveal detailed angiographic structures in human breasts. SBH-PACT features a deep penetration depth (4 cm in vivo) with high spatial and temporal resolutions (255 µm in-plane resolution and a 10 Hz 2D frame rate). By scanning the entire breast within a single breath hold (~15 s), a volumetric image can be acquired and subsequently reconstructed utilizing 3D back-projection with negligible breathing-induced motion artifacts. SBH-PACT clearly reveals tumors by observing higher blood vessel densities associated with tumors at high spatial resolution, showing early promise for high sensitivity in radiographically dense breasts. In addition to blood vessel imaging, the high imaging speed enables dynamic studies, such as photoacoustic elastography, which identifies tumors by showing less compliance. We imaged breast cancer patients with breast sizes ranging from B cup to DD cup, and skin pigmentations ranging from light to dark. SBH-PACT identified all the tumors without resorting to ionizing radiation or exogenous contrast, posing no health risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, R. L., Miller, K. D., & Jemal, A. (2017) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21387 · Cited by 14,712
Inflammation and Atherosclerosis
Libby, P., Ridker, P. M., & Maseri, A. (2002) · Circulation · doi:10.1161/hc0902.104353 · Cited by 7,724
Tumor Angiogenesis and Metastasis — Correlation in Invasive Breast Carcinoma
Weidner, N., Semple, J. P., Welch, W. R., & Folkman, J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199101033240101 · Cited by 5,627
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Role of angiogenesis in tumor growth and metastasis
Folkman, J. (2002) · Seminars in Oncology · doi:10.1053/sonc.2002.37263 · Cited by 2,404
Role of angiogenesis in tumor growth and metastasis
FOLKMAN, J. (2002) · Seminars in Oncology · doi:10.1016/s0093-7754(02)70065-1 · Cited by 2,400
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Self-citationThe American National Standards Institute
Andersen, F. A. (1984) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.1984.5006016 · Cited by 1,212
Cited by
The emerging role of photoacoustic imaging in clinical oncology
Lin, L., & Wang, L. V. (2022) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-022-00615-3 · Cited by 469
Self-citation
Metadata
- Authors
- Lin, L., Hu, P., Shi, J., Appleton, C. M., Maslov, K., Li, L., Zhang, R., & Wang, L. V.
- Venue
- Nature Communications
- Published
- 2018-06-15
- Volume
- 9
- Issue
- 1
- Pages
- 2352-2352
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2808146670
- Cited by
- 454
- References
- 48
- FWCI
- 18.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-breath-hold photoacoustic computed tomography of the breast. https://app.cochat.ai/papers/10.1038/s41467-018-04576-z
- The paper
- Lin, L., Hu, P., Shi, J., Appleton, C. M., Maslov, K., Li, L., Zhang, R., & Wang, L. V. (2018). Single-breath-hold photoacoustic computed tomography of the breast. Nature Communications. https://doi.org/10.1038/s41467-018-04576-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.