Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 259

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared-rapid gradient-echo sequence.

Jager, G J, Barentsz, J O, Oosterhof, G O, Witjes, J A, Ruijs, S J·1996·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to evaluate a magnetization-prepared-rapid gradient-echo (MP-RAGE) sequence as a three-dimensional (3D) T1-weighted MR imaging technique to reveal lymph node metastases from carcinoma of the bladder and the prostate. SUBJECTS AND METHODS: Using a 3D T1-weighted MP-RAGE sequence, MR images of 134 consecutive patients with prostatic carcinoma (n = 63) or urinary bladder carcinoma (n = 71) who were scheduled for radical prostatectomy or radical cystectomy were correlated with histopathologic findings after fine-needle aspiration biopsy (FNAB) (n = 6), open or laparoscopic pelvic lymph node dissection (n = 127), or autopsy (n = 1). MR imaging was used 10 times to guide FNAB in nine patients. RESULTS: The sensitivity, specificity, accuracy, and positive predictive valve of the technique were 75%, 98%, 90%, and 94%, respectively. Thin-slice (1.2-mm) multiplanar reconstructed images correctly revealed diseased nodes in 33 patients. However, MR imaging failed to reveal microscopic metastatic deposits in normally sized nodes in 11 patients. Two other patients had enlarged nodes without metastasis. Furthermore, FNAB guided by MR imaging revealed metastases in six of nine patients. CONCLUSION: MR imaging with a 3D MP-RAGE sequence was accurate in revealing nodal metastases from carcinoma of the prostate and bladder. This imaging technique can be used to select patients for biopsy or laparoscopic pelvic lymph node dissection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.167.6.8956585

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 259

Metadata

Authors
Jager, G. J., Barentsz, J. O., Oosterhof, G. O., Witjes, J. A., & Ruijs, S. J.
Venue
American Journal of Roentgenology
Published
1996-12
Volume
167
Issue
6
Pages
1503-1507
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2154847774
Cited by
259
References
8
FWCI
4.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared-rapid gradient-echo sequence. https://app.cochat.ai/papers/10.2214/ajr.167.6.8956585
The paper
Jager, G. J., Barentsz, J. O., Oosterhof, G. O., Witjes, J. A., & Ruijs, S. J. (1996). Pelvic adenopathy in prostatic and urinary bladder carcinoma: MR imaging with a three-dimensional TI-weighted magnetization-prepared-rapid gradient-echo sequence. American Journal of Roentgenology. https://doi.org/10.2214/ajr.167.6.8956585

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.