Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 380

The DOI matches its Crossref record.

Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients.

Bredella, M A, Tirman, P F, Peterfy, C G, Zarlingo, M, Feller, J F, Bost, F W, Belzer, J P, Wischer, T K, Genant, H K·1999·American Journal of Roentgenology

Abstract

OBJECTIVE: The purpose of this study was to assess the accuracy of routine T2-weighted MR imaging in detecting and grading articular cartilage lesions in the knee compared with arthroscopy. SUBJECTS AND METHODS: We examined 130 consecutive patients who underwent MR imaging and arthroscopy of the knee for suspected internal derangement. MR imaging consisted of axial and coronal T2-weighted fast spin-echo sequences with fat saturation and sagittal T2-weighted spin-echo sequences. Each single plane was evaluated and graded for the presence and appearance of articular cartilage defects using a standard arthroscopic grading scheme adapted to MR imaging. RESULTS: Of the 86 arthroscopically proven abnormalities, 81 were detected on MR imaging. Sensitivity of the T2-weighted fast spin-echo sequence with fat saturation was 61% for the coronal plane alone and 59% for the axial plane alone. Specificity for each plane was 99%. Sensitivity for the sagittal T2-weighted spin-echo sequence was 40%, and specificity was 100%. Sensitivity of the combination of axial and coronal T2-weighted fast spin-echo sequences with fat saturation and sagittal T2-weighted spin-echo sequence compared with arthroscopy for revealing cartilage lesions was 94%, specificity was 99%, and accuracy was 98%. Sensitivity of coronal and axial T2-weighted fast spin-echo sequences with fat saturation was 93%, and specificity was 99%. Fifty-five lesions (64%) were identically graded on MR imaging and arthroscopy. Seventy-eight lesions (90%) were within one grade using MR imaging and arthroscopy, and 84 lesions (97%) were within two grades using MR imaging and arthroscopy. CONCLUSION: T2-weighted fast spin-echo MR imaging with fat saturation is an accurate and fast technique for detecting and grading articular cartilage defects in the knee. The combination of the axial and coronal planes offers sufficient coverage of articular surfaces to provide a high sensitivity and specificity for chondral defects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.172.4.10587150

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 380

Metadata

Authors
Bredella, M. A., Tirman, P. F., Peterfy, C. G., Zarlingo, M., Feller, J. F., Bost, F. W., Belzer, J. P., Wischer, T. K., & Genant, H. K.
Venue
American Journal of Roentgenology
Published
1999-04
Volume
172
Issue
4
Pages
1073-1080
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2003315054
Cited by
380
References
0
FWCI
12.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients. https://app.cochat.ai/papers/10.2214/ajr.172.4.10587150
The paper
Bredella, M. A., Tirman, P. F., Peterfy, C. G., Zarlingo, M., Feller, J. F., Bost, F. W., Belzer, J. P., Wischer, T. K., & Genant, H. K. (1999). Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: comparison with arthroscopy in 130 patients. American Journal of Roentgenology. https://doi.org/10.2214/ajr.172.4.10587150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.