CoChat

Characterization of adrenal masses using MR imaging with histopathologic correlation.

Heinz-Peer, G, Hönigschnabl, S, Schneider, B, Niederle, B, Kaserer, K, Lechner, G · 1999 · American Journal of Roentgenology
Cited by 103

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The purpose of this study was to evaluate the sensitivity, specificity, and accuracy of MR imaging in the characterization of adrenal masses by correlating imaging findings with histopathologic results. In addition, adrenal tumors that were of an indeterminate nature on MR imaging were analyzed. SUBJECTS AND METHODS: For 114 patients with 134 adrenal masses, MR findings were compared with histologic results. In all patients, MR imaging was performed using T2-weighted fast spin-echo imaging and unenhanced and gadolinium-enhanced T1-weighted spin-echo imaging. Chemical-shift imaging was performed in 92 patients and dynamic gadolinium-enhanced studies in 108 patients. Chemical-shift images were analyzed quantitatively and qualitatively, and dynamic gadolinium-enhanced studies were qualitatively assessed. RESULTS: The sensitivity of MR imaging in differentiating between benign and malignant adrenal masses was 91%, the specificity was 94%, and the accuracy was 93%. The diagnosis at MR imaging differed from that at histology in 12 (9%) of 134 patients. Results of quantitative analyses of chemical-shift imaging techniques showed significant differences between adenomas and nonadenomas (-36.0% versus -3.7%; p < .001). Qualitative analysis provided a similar diagnostic confidence compared with quantitative analysis. Both chemical-shift and dynamic gadolinium-enhanced studies proved to be unreliable in characterizing borderline tumors (epithelial tumors with high malignant potential). Moreover, such imaging failed to allow correct diagnosis of adenomas in two patients. CONCLUSION: The characterization of an adrenal mass can be made with high sensitivity and specificity using MR imaging. The increased reliance on MR imaging seems to be based mainly on findings from chemical-shift and dynamic gadolinium-enhanced studies. The need to perform histologic sampling of incidentally discovered adrenal masses may be reduced to some problematic lesions, which will remain during the era of MR imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.173.1.10397092

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 103

Metadata

Authors
Heinz-Peer, G., Hönigschnabl, S., Schneider, B., Niederle, B., Kaserer, K., & Lechner, G.
Venue
American Journal of Roentgenology
Published
1999-07
Volume
173
Issue
1
Pages
15-22
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2061624460
Cited by
103
References
4
FWCI
5.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.