The DOI matches its Crossref record.
Incidental findings on sonography of the breast: clinical significance and diagnostic workup.
Abstract
OBJECTIVE: The purpose of this study was to determine how often physician-performed high-resolution sonography can detect nonpalpable breast lesions not revealed by mammography. A sonographic classification scheme was tested for its accuracy in predicting malignancy of incidentally detected breast lesions. SUBJECTS AND METHODS: Six thousand one hundred thirteen asymptomatic women with breast density grades 2-4 and 687 patients with palpable or mammographically detected breast masses underwent sonography as an adjunct to mammography. All sonographically detected, clinically and mammographically occult breast lesions that were not simple cysts were prospectively classified into benign, indeterminate, or malignant categories. Diagnoses were confirmed by sonographically guided fine-needle aspiration or core needle biopsy. RESULTS: In 6113 asymptomatic women, 23 malignancies in 21 patients were detected with sonography only (prevalence, 0.31%). Five additional malignant lesions were found in patients with a malignant (n = 3) or a benign (n = 2) palpable or mammographically detected index lesion. The mean size of invasive malignancies detected only by sonography was 9.1 mm, which was not significantly different from the mean size of invasive cancers detected by mammography (p = .07). The sensitivity of the prospective sonographic classification for malignancy was 100%, and the specificity was 33.5%. CONCLUSION: The use of high-resolution sonography as an adjunct to mammography in women with dense breasts may lead to detection of a significant number of otherwise occult malignancies that are no different in size from nonpalpable mammographically detected lesions. Prospective classification of these lesions based on sonographic characteristics results in a significant reduction in number of unnecessary biopsies performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kolb, T. M., Lichy, J., & Newhouse, J. H. (2002) · Radiology · doi:10.1148/radiol.2251011667 · Cited by 1,718
Breast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Elmore, J. G. (2005) · JAMA · doi:10.1001/jama.293.10.1245 · Cited by 1,075
Berg, W. A., Cosgrove, D. O., Doré, C. J., Schäfer, F. K. W., Svensson, W. E., Hooley, R. J., Ohlinger, R., Mendelson, E. B., Balu-Maestro, C., Locatelli, M., et al. (2012) · Radiology · doi:10.1148/radiol.11110640 · Cited by 845
American Cancer Society Guidelines for Breast Cancer Screening: Update 2003
Smith, R. A., Saslow, D., Andrews Sawyer, K., Burke, W., Costanza, M. E., Evans, W. P., Foster, R. S., Hendrick, E., Eyre, H. J., & Sener, S. (2003) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.53.3.141 · Cited by 770
Metadata
- Authors
- Buchberger, W., DeKoekkoek-Doll, P., Springer, P., Obrist, P., & Dünser, M.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1999-10
- Volume
- 173
- Issue
- 4
- Pages
- 921-927
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2089509595
- Cited by
- 230
- References
- 0
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidental findings on sonography of the breast: clinical significance and diagnostic workup. https://app.cochat.ai/papers/10.2214/ajr.173.4.10511149
- The paper
- Buchberger, W., DeKoekkoek-Doll, P., Springer, P., Obrist, P., & Dünser, M. (1999). Incidental findings on sonography of the breast: clinical significance and diagnostic workup. American Journal of Roentgenology. https://doi.org/10.2214/ajr.173.4.10511149
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.