CT Features of Pulmonary Alveolar Proteinosis

Holbert, J. Michael, Costello, Philip, Li, Wei, Hoffman, Robert M., Rogers, Robert M. · 2001 · American Journal of Roentgenology

Abstract

OBJECTIVE: This investigation describes the CT features of pulmonary alveolar proteinosis in a large group of patients. MATERIALS AND METHODS: A retrospective review of 139 chest CT scans (79 thick-section scans and 60 thin-section scans) from 27 patients with pathologically proven pulmonary alveolar proteinosis was performed. Two independent observers assessed the intraslice patterns and zonal distribution of disease on three CT images of each lung. The observers also graded the percentage of ground-glass opacities, air-space opacities, fibrosis, interlobular opacities, intralobular opacities, and emphysema in each slice. CT scans obtained before and after lavage related to 12 whole-lung lavage treatments on nine patients were evaluated. RESULTS: The dominant intraslice pattern was geographic, but a diffuse pattern was sometimes seen. The most common zonal pattern was uniform; a lower zone predominance was next most frequent. Ground-glass, air-space, and fibrotic opacities had a generally homogeneous craniocaudal distribution, but there was a trend toward more interlobular opacities at the lung bases (p < 0.002). Ground-glass opacities were seen on at least one scan in 100% of the patients. Interlobular opacities (85%), air-space opacities (78%), substantial fibrosis (7%), and intralobular opacities (7%) occurred less frequently. Compared with thick-section images, thin-section images showed more interlobular opacities, but no difference in ground-glass, air-space, or fibrotic disease. The proportion of lung affected by ground-glass and interlobular opacities decreased significantly (p < 0.05) after lavage. CONCLUSION: Pulmonary alveolar proteinosis does not present only with alveolar disease. The CT appearance typically combines different types of opacities with a geographic pattern and a uniform zonal distribution with variation over time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.176.5.1761287

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Holbert, J. M., Costello, P., Li, W., Hoffman, R. M., & Rogers, R. M.
Venue
American Journal of Roentgenology
Published
2001-05
Volume
176
Issue
5
Pages
1287-1294
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2153190109
Cited by
178
References
0
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CT Features of Pulmonary Alveolar Proteinosis. https://app.cochat.ai/papers/10.2214/ajr.176.5.1761287
The paper
Holbert, J. M., Costello, P., Li, W., Hoffman, R. M., & Rogers, R. M. (2001). CT Features of Pulmonary Alveolar Proteinosis. American Journal of Roentgenology. https://doi.org/10.2214/ajr.176.5.1761287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.