Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: CT accounts for considerable population-based radiation dose from radiographic diagnostic studies. The technical factors for CT examinations are not appropriately adjusted on the basis of patient size and anatomy. We hypothesized that radiation doses for routine chest CT can be reduced by 50% for the evaluation of normal structures without seriously jeopardizing image quality. SUBJECTS AND METHODS: After receiving institutional review board approval, we prospectively studied 24 patients with cancer who were 65 years old and older on a multidetector CT scanner. Each patient underwent imaging with four slices (centered at the carina) at the standard dose (220-280 mAs) and at 50%-reduced dose (110-140 mAs) at a constant 140 kVp. Single breath-hold scanning was performed with a 2.5-mm detector configuration, a tube rotation time of 0.8 sec, and a pitch of 6:1. Contiguous images were reconstructed at 5-mm intervals. Two subspecialty-trained chest radiologists who were unaware of the CT technique reviewed randomized images for overall image quality and anatomic detail of the structures in the lung, airway, mediastinum, and chest wall using a 5-point scale (1, worst; 2, suboptimal; 3, adequate; 4, very good; 5, excellent). The data were analyzed using the Wilcoxon's signed rank test. RESULTS: Although overall image quality was better with standard-dose CT, the quality of reduced-dose CT was acceptable. The differences in mean scores were statistically significant. There was a correlation of 0.59 between observers. The mean scores of standard-dose CT were always greater than or equivalent to those of low-dose CT for both observers. The assessment of great vessels and soft tissue of the chest wall contributed mainly to the differences in image quality. Both the central and peripheral lung parenchyma and the airway were adequately visualized on low-dose CT. Radiation doses (based on weighted-CT-dose index) from standard-dose CT and 50%-reduced-dose CT were 15.6-21.4 mSv and 7.8-10.7 mSv, respectively (from the manufacturer's data). CONCLUSION: Chest CT image quality appears to be acceptable for evaluating normal anatomic structures even with a 50% reduction in radiation dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Cited by
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Strategies for CT Radiation Dose Optimization
Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J.-A., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2303021726 · Cited by 1,080
Self-citationSigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
Radiation Dose Reduction in Chest CT: A Review
Kubo, T., Lin, P.-J. P., Stiller, W., Takahashi, M., Kauczor, H.-U., Ohno, Y., & Hatabu, H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2556 · Cited by 256
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
“Other clinical articles report achievable dose savings without compromising image quality by reducing tube current [39,161–165] and tube voltage depending on weight [166,167].”
Background
Metadata
- Authors
- Prasad, S. R., Wittram, C., Shepard, J.-A., McLoud, T., & Rhea, J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2002-08
- Volume
- 179
- Issue
- 2
- Pages
- 461-465
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2071804307
- Cited by
- 129
- References
- 1
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality. https://app.cochat.ai/papers/10.2214/ajr.179.2.1790461
- The paper
- Prasad, S. R., Wittram, C., Shepard, J.-A., McLoud, T., & Rhea, J. (2002). Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality. American Journal of Roentgenology. https://doi.org/10.2214/ajr.179.2.1790461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.