Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality

Prasad, Srinivasa R., Wittram, Conrad, Shepard, Jo-Anne, McLoud, Theresa, Rhea, James · 2002 · American Journal of Roentgenology
Cited by 129

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: CT accounts for considerable population-based radiation dose from radiographic diagnostic studies. The technical factors for CT examinations are not appropriately adjusted on the basis of patient size and anatomy. We hypothesized that radiation doses for routine chest CT can be reduced by 50% for the evaluation of normal structures without seriously jeopardizing image quality. SUBJECTS AND METHODS: After receiving institutional review board approval, we prospectively studied 24 patients with cancer who were 65 years old and older on a multidetector CT scanner. Each patient underwent imaging with four slices (centered at the carina) at the standard dose (220-280 mAs) and at 50%-reduced dose (110-140 mAs) at a constant 140 kVp. Single breath-hold scanning was performed with a 2.5-mm detector configuration, a tube rotation time of 0.8 sec, and a pitch of 6:1. Contiguous images were reconstructed at 5-mm intervals. Two subspecialty-trained chest radiologists who were unaware of the CT technique reviewed randomized images for overall image quality and anatomic detail of the structures in the lung, airway, mediastinum, and chest wall using a 5-point scale (1, worst; 2, suboptimal; 3, adequate; 4, very good; 5, excellent). The data were analyzed using the Wilcoxon's signed rank test. RESULTS: Although overall image quality was better with standard-dose CT, the quality of reduced-dose CT was acceptable. The differences in mean scores were statistically significant. There was a correlation of 0.59 between observers. The mean scores of standard-dose CT were always greater than or equivalent to those of low-dose CT for both observers. The assessment of great vessels and soft tissue of the chest wall contributed mainly to the differences in image quality. Both the central and peripheral lung parenchyma and the airway were adequately visualized on low-dose CT. Radiation doses (based on weighted-CT-dose index) from standard-dose CT and 50%-reduced-dose CT were 15.6-21.4 mSv and 7.8-10.7 mSv, respectively (from the manufacturer's data). CONCLUSION: Chest CT image quality appears to be acceptable for evaluating normal anatomic structures even with a 50% reduction in radiation dose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.179.2.1790461

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 129

Metadata

Authors
Prasad, S. R., Wittram, C., Shepard, J.-A., McLoud, T., & Rhea, J.
Venue
American Journal of Roentgenology
Published
2002-08
Volume
179
Issue
2
Pages
461-465
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2071804307
Cited by
129
References
1
FWCI
9.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality. https://app.cochat.ai/papers/10.2214/ajr.179.2.1790461
The paper
Prasad, S. R., Wittram, C., Shepard, J.-A., McLoud, T., & Rhea, J. (2002). Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality. American Journal of Roentgenology. https://doi.org/10.2214/ajr.179.2.1790461

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.