The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Low-Kilovoltage Multi–Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose
Abstract
PURPOSE: To assess the feasibility of low-kilovoltage (ie, 80-kV) chest computed tomography (CT) protocols for adults and the effect of such protocols on image quality and iodine dose. MATERIALS AND METHODS: Preliminarily, 90 patients (30 women, 60 men; mean age, 59 years) requiring contrast material-enhanced chest CT were randomly assigned to one of three protocol groups: protocol A, with use of 80 kV and 135 mAs; protocol B, with use of 80 kV and 180 mAs; or the standard protocol, with use of 120 kV and 90 mAs. Contrast material injection protocols were standardized in all groups. Image noise was calculated and plotted against patient weight. Subsequently, another 52 consecutive patients (11 women, 41 men; mean age, 57 years) were assigned to one of the protocols according to their weight: Patients weighing less than 60 kg were assigned to protocol A; patients weighing 60-75 kg, to protocol B; and patients weighing more than 75 kg, to the standard protocol. Two readers evaluated the CT images qualitatively by using a five-point scale. Statistical analyses were performed by using analysis of variance, kappa, and Fisher exact tests. RESULTS: In the preliminary study, the mean image noise values with protocols A (24 HU) and B (20 HU) were significantly higher (P <.001) than that with the standard protocol (12 HU). With protocols A and B, in the patients weighing more than 60 kg and more than 75 kg, respectively, the noise increased exponentially with patient weight. In the subsequent study, qualitative analysis revealed no significant difference between the low-kilovoltage examinations and the standard examination. Compared with use of the standard protocol, use of protocols A and B resulted in the iodine-based contrast material dose being reduced by 54% and 39%, respectively. CONCLUSION: Weight-adapted low-kilovoltage contrast-enhanced chest CT examinations can be routinely performed with 80 kV. Use of these protocols results in good diagnostic image quality and makes it possible to reduce contrast material use by more than 50%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Helical CT of the Body: Are Settings Adjusted for Pediatric Patients?
Paterson, A., Frush, D. P., & Donnelly, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760297 · Cited by 422
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Perfect is the enemy of the very good
Slovis, T. L., & Berdon, W. E. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0669-8 · Cited by 175
Lucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.4.1750985 · Cited by 165
Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153
Radiation Exposure and Image Quality in Chest CT Examinations
Ravenel, J. G., Scalzetti, E. M., Huda, W., & Garrisi, W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770279 · Cited by 142
Standard-Dose and 50%—Reduced-Dose Chest CT: Comparing the Effect on Image Quality
Prasad, S. R., Wittram, C., Shepard, J.-A. O., McLoud, T. C., & Rhea, J. T. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790461 · Cited by 130
Cited by
Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
Bae, K. T. (2010) · Radiology · doi:10.1148/radiol.10090908 · Cited by 1,067
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Marin, D., Nelson, R. C., Schindera, S. T., Richard, S., Youngblood, R. S., Yoshizumi, T. T., & Samei, E. (2010) · Radiology · doi:10.1148/radiol.09090094 · Cited by 484
Nakayama, Y., Awai, K., Funama, Y., Hatemura, M., Imuta, M., Nakaura, T., Ryu, D., Morishita, S., Sultana, S., Sato, N., et al. (2005) · Radiology · doi:10.1148/radiol.2373041655 · Cited by 422
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Metadata
- Authors
- Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F.
- Venue
- Radiology
- Published
- 2004-04
- Volume
- 231
- Issue
- 1
- Pages
- 169-174
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2038983969
- Cited by
- 372
- References
- 13
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Kilovoltage Multi–Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose. https://app.cochat.ai/papers/10.1148/radiol.2311030191
- The paper
- Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004). Low-Kilovoltage Multi–Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose. Radiology. https://doi.org/10.1148/radiol.2311030191
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.