Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 372

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Low-Kilovoltage Multi–Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose

Sigal-Cinqualbre, Anne B., Hennequin, Remi, Abada, Hicham T., Chen, Xiaoyan, Paul, Jean-François·2004·Radiology

Abstract

PURPOSE: To assess the feasibility of low-kilovoltage (ie, 80-kV) chest computed tomography (CT) protocols for adults and the effect of such protocols on image quality and iodine dose. MATERIALS AND METHODS: Preliminarily, 90 patients (30 women, 60 men; mean age, 59 years) requiring contrast material-enhanced chest CT were randomly assigned to one of three protocol groups: protocol A, with use of 80 kV and 135 mAs; protocol B, with use of 80 kV and 180 mAs; or the standard protocol, with use of 120 kV and 90 mAs. Contrast material injection protocols were standardized in all groups. Image noise was calculated and plotted against patient weight. Subsequently, another 52 consecutive patients (11 women, 41 men; mean age, 57 years) were assigned to one of the protocols according to their weight: Patients weighing less than 60 kg were assigned to protocol A; patients weighing 60-75 kg, to protocol B; and patients weighing more than 75 kg, to the standard protocol. Two readers evaluated the CT images qualitatively by using a five-point scale. Statistical analyses were performed by using analysis of variance, kappa, and Fisher exact tests. RESULTS: In the preliminary study, the mean image noise values with protocols A (24 HU) and B (20 HU) were significantly higher (P <.001) than that with the standard protocol (12 HU). With protocols A and B, in the patients weighing more than 60 kg and more than 75 kg, respectively, the noise increased exponentially with patient weight. In the subsequent study, qualitative analysis revealed no significant difference between the low-kilovoltage examinations and the standard examination. Compared with use of the standard protocol, use of protocols A and B resulted in the iodine-based contrast material dose being reduced by 54% and 39%, respectively. CONCLUSION: Weight-adapted low-kilovoltage contrast-enhanced chest CT examinations can be routinely performed with 80 kV. Use of these protocols results in good diagnostic image quality and makes it possible to reduce contrast material use by more than 50%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2311030191

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 372

Metadata

Authors
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F.
Venue
Radiology
Published
2004-04
Volume
231
Issue
1
Pages
169-174
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2038983969
Cited by
372
References
13
FWCI
13.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-Kilovoltage Multi–Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose. https://app.cochat.ai/papers/10.1148/radiol.2311030191
The paper
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004). Low-Kilovoltage Multi–Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose. Radiology. https://doi.org/10.1148/radiol.2311030191

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.