In-Plane Bismuth Breast Shields for Pediatric CT: Effects on Radiation Dose and Image Quality Using Experimental and Clinical Data
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of our study was to evaluate the amount of radiation dose reduction and its effect on image quality when using an in-plane bismuth breast shield for multidetector CT (MDCT) of the chest and abdomen in female pediatric patients. SUBJECTS AND METHODS: Fifty consecutive MDCT examinations (chest, 29; abdomen, 21) of female pediatric patients (mean age, 9 years; range, 2 months-18 years) were performed with a 2-ply (1.7 g of bismuth per square centimeter) bismuth shield (three sizes to accommodate patients of varying sizes) overlying the patient's breasts. MDCT images were evaluated for a perceptible difference in image quality in the lungs at the anatomic level under the shield as compared with nonshielded lung and whether the images were of diagnostic quality. In addition, 2-mm regions of interest were placed in the peripheral anterior and posterior portions of each lung in shielded and nonshielded areas, and noise (standard deviation in Hounsfield units) was measured in the regions. Differences among the regions in noise were compared for shielded versus nonshielded areas (paired t test). To measure differences in actual dose, we also evaluated the breast shield with an infant anthropomorphic phantom using thermoluminescent detectors in the breast tissue. The phantom was imaged with and without the breast shield using identical MDCT parameters. RESULTS: All MDCT scans of patients were of diagnostic quality with no perceptible difference in image quality in shielded versus nonshielded lung. We found no statistically significant difference in noise between the shielded and nonshielded lung regions of interest (shielded: mean noise, 17.3 H; nonshielded: mean noise, 18.8 H; p = 0.5180). Phantom measurements revealed a 29% reduction in radiation dose to the breast when a medium-dose MDCT protocol was used. CONCLUSION: Bismuth in-plane breast shielding for pediatric MDCT decreased radiation dose to the breast without qualitative or quantitative changes in image quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222
Studies of the Mortality of Atomic Bomb Survivors. Report 12, Part I. Cancer: 1950-1990
Pierce, D. A., Shimizu, Y., Preston, D. L., Vaeth, M., & Mabuchi, K. (1996) · Radiation Research · doi:10.2307/3579391 · Cited by 941
CT scanning: patterns of use and dose
Mettler, F. A., Wiest, P. W., Locken, J. A., & Kelsey, C. A. (2000) · Journal of Radiological Protection · doi:10.1088/0952-4746/20/4/301 · Cited by 664
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Self-citationHelical CT of the Body: Are Settings Adjusted for Pediatric Patients?
Paterson, A., Frush, D. P., & Donnelly, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760297 · Cited by 422
Self-citationIncidence of Female Breast Cancer among Atomic Bomb Survivors, 1950-1985
Tokunaga, M., Land, C. E., Tokuoka, S., Nishimori, I., Soda, M., & Akiba, S. (1994) · Radiation Research · doi:10.2307/3578591 · Cited by 285
Breast Cancer in Women With Scoliosis Exposed to Multiple Diagnostic X Rays
Hoffman, D. A., Lonstein, J. E., Morin, M. M., Visscher, W., Harris, B. S. H., & Boice, J. D. (1989) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/81.17.1307 · Cited by 280
Hopper, K. D., King, S. H., Lobell, M. E., TenHave, T. R., & Weaver, J. S. (1997) · Radiology · doi:10.1148/radiology.205.3.9393547 · Cited by 194
Lucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.4.1750985 · Cited by 165
Self-citationINCREASED RISK OF BREAST CANCER AFTER LOW-DOSE IRRADIATION
Modan, B., Alfandary, E., Chetrit, A., & Katz, L. (1989) · The Lancet · doi:10.1016/s0140-6736(89)92140-5 · Cited by 108
Feasibility of high-resolution, low-dose chest CT in evaluating the pediatric chest
Ambrosino, M. M., Genieser, N. B., Roche, K. J., Kaul, A., & Lawrence, R. M. (1994) · Pediatric Radiology · doi:10.1007/bf02017649 · Cited by 82
Rogers, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760287 · Cited by 80
Radiation dose reduction in CT of the pediatric pelvis.
Kamel, I. R., Hernandez, R. J., Martin, J. E., Schlesinger, A. E., Niklason, L. T., & Guire, K. E. (1994) · Radiology · doi:10.1148/radiology.190.3.8115611 · Cited by 68
Risk and benefit in paediatric radiology
Roebuck, D. J. (1999) · Pediatric Radiology · doi:10.1007/s002470050666 · Cited by 42
Radiation dose reduction in pediatric CT
Robinson, A. E., Hill, E. P., & Harpen, M. D. (1986) · Pediatric Radiology · doi:10.1007/bf02387506 · Cited by 36
Tokunaga, M., Land, C. E., Aoki, Y., Yamamoto, T., Asano, M., Sato, E., Tokuoka, S., Sakamoto, G., & Page, D. L. (1993) · Cancer · doi:10.1002/1097-0142(19930901)72:5<1657::aid-cncr2820720527>3.0.co;2-n · Cited by 25
Les effets cancérogènes des faibles doses de radiations
Tubiana, M. (1999) · Cancer/Radiothérapie · doi:10.1016/s1278-3218(99)80053-5 · Cited by 16
Cited by
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Frush, D. P., Donnelly, L. F., & Rosen, N. S. (2003) · Pediatrics · doi:10.1542/peds.112.4.951 · Cited by 625
Self-citationSCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT
Halliburton, S. S., Abbara, S., Chen, M. Y., Gentry, R., Mahesh, M., Raff, G. L., Shaw, L. J., & Hausleiter, J. (2011) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2011.06.001 · Cited by 491
Schueller-Weidekamm, C., Schaefer-Prokop, C. M., Weber, M., Herold, C. J., & Prokop, M. (2006) · Radiology · doi:10.1148/radiol.2413040128 · Cited by 258
Multidetector CT in children: current concepts and dose reduction strategies
Nievelstein, R. A. J., van Dam, I. M., & van der Molen, A. J. (2010) · Pediatric Radiology · doi:10.1007/s00247-010-1714-7 · Cited by 201
“, breast, thyroid gland and eye lens) to reduce organ doses has been suggested [45, 46].”
Background
Metadata
- Authors
- Fricke, B. L., Donnelly, L. F., Frush, D. P., Yoshizumi, T., Varchena, V., Poe, S. A., & Lucaya, J.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2003-02
- Volume
- 180
- Issue
- 2
- Pages
- 407-411
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W1997499703
- Cited by
- 183
- References
- 17
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.