Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Reversed Halo Sign on High-Resolution CT of Cryptogenic Organizing Pneumonia: Diagnostic Implications

Open access
Kim, Sang Jin, Lee, Kyung Soo, Ryu, Young Hoon, Yoon, Young Cheol, Choe, Kyu Ok, Kim, Tae Sung, Sung, Ki Jun·2003·American Journal of Roentgenology

Abstract

OBJECTIVE: The aim of our study was to evaluate the usefulness of the reversed halo sign on high-resolution CT in the diagnosis of cryptogenic organizing pneumonia. MATERIALS AND METHODS: Between 1996 and 2001, we saw 31 patients with biopsy-proven cryptogenic organizing pneumonia. During the same period, we also saw 30 patients with non-cryptogenic organizing pneumonia diseases, from which cryptogenic organizing pneumonia should be differentiated: Wegener's granulomatosis (n = 14), diffuse bronchioloalveolar carcinoma (n = 10), chronic eosinophilic pneumonia (n = 5), and Churg-Strauss syndrome (n = 1). Two independent observers analyzed CT findings and recorded how frequently the so-called reversed halo sign (central ground-glass opacity and surrounding air-space consolidation of crescentic and ring shape) was seen on high-resolution CT. RESULTS: The most common patterns of parenchymal abnormalities of cryptogenic organizing pneumonia were ground-glass opacity (28/31 patients, 90%) and consolidation (27/31, 87%). The ground-glass opacity pattern showed random distribution, and the consolidation pattern showed subpleural or peribronchovascular (20/27 patients, 74%) distribution with predominance in the middle or lower lung zone. The reversed CT halo sign was seen in six (19%) of 31 patients with cryptogenic organizing pneumonia and in none of the patients with the diseases that needed to be differentiated from cryptogenic organizing pneumonia on CT. CONCLUSION: The reversed halo sign, although seen only in one fifth of patients with the disease, appears relatively specific to make a diagnosis of cryptogenic organizing pneumonia on CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2214/ajr.180.5.1801251

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 327

Metadata

Authors
Kim, S. J., Lee, K. S., Ryu, Y. H., Yoon, Y. C., Choe, K. O., Kim, T. S., & Sung, K. J.
Venue
American Journal of Roentgenology
Published
2003-05
Volume
180
Issue
5
Pages
1251-1254
ISSN
  • 0002-9580 (ISSN-L)
  • 0361-803X
  • 1546-3141
OpenAlex
W2121350896
Cited by
327
References
10
FWCI
4.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reversed Halo Sign on High-Resolution CT of Cryptogenic Organizing Pneumonia: Diagnostic Implications. https://app.cochat.ai/papers/10.2214/ajr.180.5.1801251
The paper
Kim, S. J., Lee, K. S., Ryu, Y. H., Yoon, Y. C., Choe, K. O., Kim, T. S., & Sung, K. J. (2003). Reversed Halo Sign on High-Resolution CT of Cryptogenic Organizing Pneumonia: Diagnostic Implications. American Journal of Roentgenology. https://doi.org/10.2214/ajr.180.5.1801251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.