The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Blood Pool MR Angiography of Aortic Stent-Graft Endoleak
Open accessAbstract
OBJECTIVE: The purpose of our research was to investigate the value of a blood pool contrast agent in detecting endoleaks on MR angiography after endoluminal stent-graft repair of infrarenal aortic aneurysms. CONCLUSION: Blood pool MR angiography using Ferumoxytol reveals more aortic stent-graft endoleaks than does CT angiography and depicts more endoleaks 24 hr after administration than during the immediate arterial phase because of a 50-fold increase in the volume of enhancement in the aneurysmal sac outside the stent-graft.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“They showed that iron oxide nanoparticle-enhanced MRA is superior to CT angiography for the detection of endoleaks.”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [182]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
White, G. H., Yu, W., May, J. R., Chaufour, X., & Stephen, M. S. (1997) · Journal of Endovascular Therapy · doi:10.1177/152660289700400207 · Cited by 770
Predictors of bleeding complications in percutaneous ultrasound-guided renal biopsy
Manno, C., Strippoli, G. F., Arnesano, L., Bonifati, C., Campobasso, N., Gesualdo, L., & Schena, F. P. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00922.x · Cited by 308
Li, W., Tutton, S., Vu, A. T., Pierchala, L., Li, B. S. Y., Lewis, J. M., Prasad, P. V., & Edelman, R. R. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20235 · Cited by 233
Muldoon, L. L., Manninger, S., Pinkston, K. E., & Neuwelt, E. A. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.785 · Cited by 190
MR angiography with an ultrasmall superparamagnetic iron oxide blood pool agent
Anzai, Y., Prince, M. R., Chenevert, T. L., Maki, J. H., Londy, F. J., & McLachlan, S. J. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070132 · Cited by 153
Self-citationHelical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition.
Golzarian, J., Dussaussois, L., Abada, H. T., Gevenois, P. A., Gansbeke, D. V., Ferreira, J., & Struyven, J. L. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.171.2.9694445 · Cited by 144
Endovascular repair of abdominal aortic aneurysm: value of postoperative follow-up with helical CT.
Rozenblit, A. M., Marin, M. L., Veith, F. J., Cynamon, J., Wahl, S. I., & Bakal, C. W. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.165.6.7484590 · Cited by 110
MR contrast material for vascular enhancement: value of superparamagnetic iron oxide.
Mayo-Smith, W. W., Saini, S., Slater, G. J., Kaufman, J. A., Sharma, P., & Hahn, P. F. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571910 · Cited by 91
The safety and efficacy of ferumoxytol therapy in anemic chronic kidney disease patients
Spinowitz, B., Schwenk, M. H., Jacobs, P. M., Bolton, W. K., Kaplan, M. R., Charytan, C., & Galler, M. (2005) · Kidney International · doi:10.1111/j.1523-1755.2005.00598.x · Cited by 74
Self-citationAhlström, K. H., Johansson, L. O. M., Rodenburg, J. B., Ragnarsson, A., Åkeson, P., & Børseth, A. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn10865 · Cited by 69
Functional magnetic resonance imaging of the kidney using macromolecular contrast agents
Choyke, P. L., & Kobayashi, H. (2005) · Abdominal Imaging · doi:10.1007/s00261-005-0390-9 · Cited by 52
SIMON, G. H., Raatschen, H., Wendland, M. F., von Vopelius‐Feldt, J., Fu, Y., Chen, M., & Daldrup-Link, H. E. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.05.014 · Cited by 32
Hilfiker, P. R., Weishaupt, D., Kacl, G. M., Hetzer, F. H., Griff, M. D., Ruehm, S. G., & Debatin, J. F. (1999) · Gut · doi:10.1136/gut.45.4.581 · Cited by 31
Imaging brain tumors with ferumoxtran-10, a nanoparticle magnetic resonance contrast agent
Murillo, T. P., Sandquist, C. A., Jacobs, P. M., Nesbit, G. M., Manninger, S., & Neuwelt, E. A. (2005) · Therapy · doi:10.1586/14750708.2.6.871 · Cited by 29
Self-citationWeishaupt, D., Hetzer, F. H., Ruehm, S. G., Patak, M. A., Schmidt, M., & Debatin, J. F. (2000) · European Radiology · doi:10.1007/s003300000519 · Cited by 28
MR Angiography of Endoleak with Inconclusive Concomitant CT Angiography
Wicky, S., Fan, C.-M., Geller, S. C., Greenfield, A. J., Santilli, J., & Waltman, A. C. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.3.1810736 · Cited by 25
Hilfiker, P. R., Zimmermann-Paul, G. G., Schmidt, M., Klotz, H. P., Kacl, G. M., & Debatin, J. F. (1998) · Radiology · doi:10.1148/radiology.209.3.9844672 · Cited by 18
Contrast-Enhanced Magnetic Resonance Angiography
Vasile, J. V., Newman, T. M., Prince, M. R., Rusch, D., Greenspun, D. T., Allen, R. J., & Levine, J. L. (2011) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2011.03.008 · Cited by 11
Self-citationDiagnosis and management of endoleaks after endovascular aneurysm repair: role of MRI
Pitton, M. B. (2005) · Abdominal Imaging · doi:10.1007/s00261-005-0370-0 · Cited by 7
Contrast Agents: Innovations and Potential Applications for Body MR Angiography
Hood, M. N., & Ho, V. B. (2005) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2004.12.011 · Cited by 5
Research works printed but not linked: 1
- 10.1583/1074-6218(1997)004<0152:EAACOE>2.0.CO;2 · DOI
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
Clinical Translation of Nanomedicine
Min, Y., Caster, J. M., Eblan, M. J., & Wang, A. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00116 · Cited by 803
Jeon, M., Halbert, M. V., Stephen, Z. R., & Zhang, M. (2020) · Advanced Materials · doi:10.1002/adma.201906539 · Cited by 497
Emerging applications for ferumoxytol as a contrast agent in MRI
Bashir, M. R., Bhatti, L., Marin, D., & Nelson, R. C. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24691 · Cited by 373
Current and potential imaging applications of ferumoxytol for magnetic resonance imaging
Toth, G. B., Varallyay, C. G., Horvath, A., Bashir, M. R., Choyke, P. L., Daldrup-Link, H. E., Dosa, E., Finn, J. P., Gahramanov, S., Harisinghani, M., et al. (2017) · Kidney International · doi:10.1016/j.kint.2016.12.037 · Cited by 317
Metadata
- Authors
- Ersoy, H., Jacobs, P., Kent, C. K., & Prince, M. R.
- Affiliations
- Cornell University (US)
- Cambridge Intellectual Property (United Kingdom) (GB)
- Department of Vascular Surgery, Weill Medical College of Cornell University, New York, NY 10021.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2004-05
- Volume
- 182
- Issue
- 5
- Pages
- 1181-1186
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2022280660
- Cited by
- 119
- References
- 20
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 5 · 2023: 1 · 2022: 4 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 6 · 2016: 5 · 2015: 9 · 2014: 7 · 2013: 9 · 2012: 3
- FWCI
- 7.00
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- American Journal of Roentgenology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- endoleak, aortic stent graft, blood pool contrast agent, ferumoxytol, magnetic resonance angiography, infrarenal aortic aneurysm, endovascular repair, CT angiography comparison
- MeSH terms
- Aged, Aged, 80 and over, Aortography, Blood Vessel Prosthesis, Contrast Media, Female, Humans, Iron, Male, Middle Aged, Oxides, Postoperative Complications, Stents, Aortic Aneurysm, Abdominal, Magnetic Resonance Angiography, Ferrosoferric Oxide
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review