Cuffless Blood Pressure Monitoring: Promises and Challenges
Open accessThe DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
Current BP measurements are on the basis of traditional BP cuff approaches. Ambulatory BP monitoring, at 15- to 30-minute intervals usually over 24 hours, provides sufficiently continuous readings that are superior to the office-based snapshot, but this system is not suitable for frequent repeated use. A true continuous BP measurement that could collect BP passively and frequently would require a cuffless method that could be worn by the patient, with the data stored electronically much the same way that heart rate and heart rhythm are already done routinely. Ideally, BP should be measured continuously and frequently during diverse activities during both daytime and nighttime in the same subject by means of novel devices. There is increasing excitement for newer methods to measure BP on the basis of sensors and algorithm development. As new devices are refined and their accuracy is improved, it will be possible to better assess masked hypertension, nocturnal hypertension, and the severity and variability of BP. In this review, we discuss the progression in the field, particularly in the last 5 years, ending with sensor-based approaches that incorporate machine learning algorithms to personalized medicine.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
The citation lists are queued
They are fetched later and appear here then.
References 99 · Cited by 101
Research works printed but not linked: 1
- Esmaili, 2017, Nonlinear cuffless blood pressure estimation of healthy subjects using pulse transit time and arrival time, IEEE Trans Instrum Meas, 66, 3299, 10.1109/TIM.2017.2745081 · DOI · Paper page
Metadata
- Authors
- Pandit, J. A., Lores, E., & Batlle, D.
- Affiliations
- Northwestern University (US)
- Venue
- Clinical Journal of the American Society of Nephrology
- Published
- 2020-07-17
- Volume
- 15
- Issue
- 10
- Pages
- 1531-1538
- ISSN
- 1555-9041 (ISSN-L)
- 1555-905X
- PMC
- PMC7536750
- OpenAlex
- W3042891861
- Cited by
- 101
- References
- 99
- Citations by year
- 2026: 12 · 2025: 21 · 2024: 16 · 2023: 14 · 2022: 26 · 2021: 11 · 2020: 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- Locations
- Clinical Journal of the American Society of Nephrology (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK104785)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- cuffless blood pressure measurement, ambulatory blood pressure monitoring, continuous blood pressure measurement, machine learning algorithms, masked hypertension, nocturnal hypertension, blood pressure variability, personalized medicine
- MeSH terms
- Machine Learning, Wearable Electronic Devices, Blood Pressure, Calibration, Humans, Hypertension, Manometry, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cuffless Blood Pressure Monitoring: Promises and Challenges. https://app.cochat.ai/papers/10.2215/cjn.03680320
- The paper
- Pandit, J. A., Lores, E., & Batlle, D. (2020). Cuffless Blood Pressure Monitoring: Promises and Challenges. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.03680320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.