CoChat

Cuffless Blood Pressure Monitoring: Promises and Challenges

Open access
Pandit, Jay A., Lores, Enrique, Batlle, Daniel · 2020 · Clinical Journal of the American Society of Nephrology

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Current BP measurements are on the basis of traditional BP cuff approaches. Ambulatory BP monitoring, at 15- to 30-minute intervals usually over 24 hours, provides sufficiently continuous readings that are superior to the office-based snapshot, but this system is not suitable for frequent repeated use. A true continuous BP measurement that could collect BP passively and frequently would require a cuffless method that could be worn by the patient, with the data stored electronically much the same way that heart rate and heart rhythm are already done routinely. Ideally, BP should be measured continuously and frequently during diverse activities during both daytime and nighttime in the same subject by means of novel devices. There is increasing excitement for newer methods to measure BP on the basis of sensors and algorithm development. As new devices are refined and their accuracy is improved, it will be possible to better assess masked hypertension, nocturnal hypertension, and the severity and variability of BP. In this review, we discuss the progression in the field, particularly in the last 5 years, ending with sensor-based approaches that incorporate machine learning algorithms to personalized medicine.

Overview

Integrity signals

Registry

Crossref · 10.2215/cjn.03680320

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 99 · Cited by 101

Research works printed but not linked: 1

  1. Esmaili, 2017, Nonlinear cuffless blood pressure estimation of healthy subjects using pulse transit time and arrival time, IEEE Trans Instrum Meas, 66, 3299, 10.1109/TIM.2017.2745081 · DOI · Paper page

Metadata

Authors
Pandit, J. A., Lores, E., & Batlle, D.
Affiliations
Northwestern University (US)
Venue
Clinical Journal of the American Society of Nephrology
Published
2020-07-17
Volume
15
Issue
10
Pages
1531-1538
ISSN
  • 1555-9041 (ISSN-L)
  • 1555-905X
OpenAlex
W3042891861
Cited by
101
References
99
Citations by year
2026: 12 · 2025: 21 · 2024: 16 · 2023: 14 · 2022: 26 · 2021: 11 · 2020: 1
FWCI
4.07
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Clinical Journal of the American Society of Nephrology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (R01DK104785)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
cuffless blood pressure measurement, ambulatory blood pressure monitoring, continuous blood pressure measurement, machine learning algorithms, masked hypertension, nocturnal hypertension, blood pressure variability, personalized medicine
MeSH terms
Machine Learning, Wearable Electronic Devices, Blood Pressure, Calibration, Humans, Hypertension, Manometry, Reproducibility of Results, Blood Pressure Monitoring, Ambulatory, Pulse Wave Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cuffless Blood Pressure Monitoring: Promises and Challenges. https://app.cochat.ai/papers/10.2215/cjn.03680320
The paper
Pandit, J. A., Lores, E., & Batlle, D. (2020). Cuffless Blood Pressure Monitoring: Promises and Challenges. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.03680320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.