Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

High-Normal Serum Uric Acid Is Associated with Impaired Glomerular Filtration Rate in Nonproteinuric Patients with Type 1 Diabetes

Open access
Rosolowsky, Elizabeth T., Ficociello, Linda H., Maselli, Nicholas J., Niewczas, Monika A., Binns, Amanda L., Roshan, Bijan, Warram, James H., Krolewski, Andrzej S.·2008·Clinical Journal of the American Society of Nephrology

Abstract

BACKGROUND AND OBJECTIVES: Early renal function decline begins before the onset of proteinuria in patients with type 1 diabetes. The association of elevated serum uric acid with advanced impaired renal function prompts an examination of its role in early renal function decline in patients before proteinuria develops. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Patients with type 1 diabetes and normoalbuminuria or microalbuminuria were recruited to the Second Joslin Kidney Study. A medical history and measurements of BP, hemoglobin A1c, albumin excretion rate, and serum concentrations of uric acid and cystatin C were obtained. Estimated glomerular filtration rate was measured by a cystatin C-based formula. RESULTS: We studied 364 patients with normoalbuminuria and 311 patients with microalbuminuria. Mean glomerular filtration rate in these groups was 119 and 99 ml/min, respectively. Mildly or moderately impaired renal function (<90 ml/min) was present in 10% of those with normoalbuminuria and 36% of those with microalbuminuria. In univariate and multivariate analyses, lower glomerular filtration rate was strongly and independently associated with higher serum uric acid and higher urinary albumin excretion rate, older age, and antihypertensive treatment. CONCLUSIONS: Serum uric acid concentration in the high-normal range is associated with impaired renal function in patients with type 1 diabetes. Follow-up studies are needed to confirm that this level of serum uric acid is a risk factor for early renal function decline in type 1 diabetes and to determine whether its reduction would prevent the decline.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.04271007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Rosolowsky, E. T., Ficociello, L. H., Maselli, N. J., Niewczas, M. A., Binns, A. L., Roshan, B., Warram, J. H., & Krolewski, A. S.
Venue
Clinical Journal of the American Society of Nephrology
Published
2008-05
Volume
3
Issue
3
Pages
706-713
ISSN
1555-9041 (ISSN-L)
OpenAlex
W2089725385
Cited by
161
References
0
FWCI
10.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Normal Serum Uric Acid Is Associated with Impaired Glomerular Filtration Rate in Nonproteinuric Patients with Type 1 Diabetes. https://app.cochat.ai/papers/10.2215/cjn.04271007
The paper
Rosolowsky, E. T., Ficociello, L. H., Maselli, N. J., Niewczas, M. A., Binns, A. L., Roshan, B., Warram, J. H., & Krolewski, A. S. (2008). High-Normal Serum Uric Acid Is Associated with Impaired Glomerular Filtration Rate in Nonproteinuric Patients with Type 1 Diabetes. Clinical Journal of the American Society of Nephrology. https://doi.org/10.2215/cjn.04271007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.