The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Current Status of Gadolinium Toxicity in Patients with Kidney Disease
Abstract
Gadolinium-based contrast (GBC) agents have recently been the subject of intense interest for physicians across numerous specialties. These agents are widely used as contrast for magnetic resonance imaging and have been generally considered safe. Early on, phase III trials and small studies in low-risk patients suggested a benign renal profile; however, more recent studies raised the possibility of nephrotoxicity, although it is not clear whether it approaches the incidence of nephropathy associated with iodinated radiocontrast. In 2006, reports of a rare systemic fibrosing condition called nephrogenic systemic fibrosis (NSF) were recently linked to exposure of patients with advanced kidney disease to GBC agents. Analysis of the data suggests that certain GBC agents are more likely to be associated with NSF. Also, not all patients with kidney disease are at risk for developing NSF, only those with advanced acute or chronic kidney disease. Avoidance of GBC exposure is the best approach for high-risk patients. When GBC is required to obtain optimal images, use of low dosages of more stable macrocyclic agents is safer and preferred. This article reviews the current status of GBC agents as nephrotoxins and causes of NSF and provides opinions on how to use these agents in patients with underlying kidney disease.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ever more evidence is accumulating that gadolinium-based contrast enhancement agents induce nephrogenic systemic fibrosis (NSF) in patients with underlying kidney disease. As a consequence, gadolinium-based contrast agents are contraindicated in patients with impaired renal function [187].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [187]
Citations
Cites
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,862
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,398
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,011
Gadodiamide-Associated Nephrogenic Systemic Fibrosis: Why Radiologists Should Be Concerned
Broome, D. R., Girguis, M. S., Baron, P. W., Cottrell, A. C., Kjellin, I. B., & Kirk, G. A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1094 · Cited by 599
Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis
High, W. A., Ayers, R. A., Chandler, J. P., Zito, G., & Cowper, S. E. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.10.047 · Cited by 542
Nephrogenic Fibrosing Dermopathy
Cowper, S. E., Su, L. D., Bhawan, J., Robin, H. S., & LeBoit, P. E. (2001) · American Journal of Dermatopathology · doi:10.1097/00000372-200110000-00001 · Cited by 473
Nephrotoxicity of high‐dose gadolinium compared with iodinated contrast
Prince, M. R., Arnoldus, C. L., & Frisoli, J. K. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060129 · Cited by 401
Gadolinium deposition in nephrogenic fibrosing dermopathy
Boyd, A. S., Zic, J. A., & Abraham, J. L. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.10.048 · Cited by 374
Nephrogenic systemic fibrosis: a serious late adverse reaction to gadodiamide
Thomsen, H. S. (2006) · European Radiology · doi:10.1007/s00330-006-0495-8 · Cited by 352
Collidge, T., Thomson, P. C., Mark, P. B., Traynor, J. P., Jardine, A. G., Morris, S., Simpson, K., & Roditi, G. (2007) · Radiology · doi:10.1148/radiol.2451070353 · Cited by 319
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 275
Pike, D. B., Shiu, Y.-T. E., Cho, Y.-F., Le, H., Somarathna, M. S., Isayeva, T., Guo, L., Symons, J. D., Kevil, C. G., Totenhagen, J. W., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-40683-7 · Cited by 25
van Gastel, M. D. A., Messchendorp, A. L., Kappert, P., Kaatee, M. A., de Jong, M., Renken, R. J., Horst, G. J. T., Mahesh, S. V. K., & Gansevoort, R. T. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1285-2 · Cited by 24
Bardin, T., & Richette, P. (2009) · Current Opinion in Rheumatology · doi:10.1097/bor.0b013e328333bf3d · Cited by 24
Daldrup-Link, H. E., Theruvath, A. J., Rashidi, A., Iv, M., Majzner, R. G., Spunt, S. L., Goodman, S. B., & Moseley, M. E. (2021) · Pediatric Radiology · doi:10.1007/s00247-021-05098-5 · Cited by 24
Gorelik, Y., Yaseen, H., Heyman, S. N., & Khamaisi, M. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000534 · Cited by 23
Tjörnstrand, J., Neuman, P., Svensson, J., Lundin, B., Dahlberg, L., & Tiderius, C. J. (2019) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2019.06.012 · Cited by 23
Batra, A., Barnard, A. M., Lott, D. J., Willcocks, R. J., Forbes, S. C., Chakraborty, S., Daniels, M. J., Arbogast, J., Triplett, W. T., Henricson, E., et al. (2022) · BMC Cardiovascular Disorders · doi:10.1186/s12872-022-02688-5 · Cited by 24
The role of echocardiographic study in patients with chronic kidney disease
Liu, Y.-W., Su, C.-T., Song, E.-J., Tsai, W., Li, Y., Tsai, L.-M., Chen, J.-H., & Sung, J. (2015) · Journal of the Formosan Medical Association · doi:10.1016/j.jfma.2015.06.009 · Cited by 23
Shape memory polymers with enhanced visibility for magnetic resonance- and X-ray imaging modalities
Weems, A. C., Szafron, J. M., Easley, A. D., Herting, S. M., Smolen, J. A., & Maitland, D. J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.045 · Cited by 23
Feasibility of Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Low-Dose Gadolinium
He, D., Chatterjee, A., Fan, X., Wang, S., Eggener, S. E., Yousuf, A. N., Antic, T., Oto, A., & Karczmar, G. S. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000466 · Cited by 23
Gandhi, S., Sweeney, H. L., Hart, C. C., Han, R., & Perry, C. G. R. (2024) · Cells · doi:10.3390/cells13141168 · Cited by 29
Current Opinions in Renovascular Hypertension
Mehta, A. N., & Fenves, A. Z. (2010) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2010.11928627 · Cited by 22
Hoppe, H., Spagnuolo, S., Froehlich, J. M., Nievergelt, H., Dinkel, H., Gretener, S. B., & Thoeny, H. C. (2009) · European Radiology · doi:10.1007/s00330-009-1586-0 · Cited by 22
Polymer‐Coated Radioluminescent Nanoparticles for Quantitative Imaging of Drug Delivery
Moore, T. L., Wang, F., Chen, H., Grimes, S. W., Anker, J. N., & Alexis, F. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400949 · Cited by 22
Multifunctional nanocarriers for codelivery of nucleic acids and chemotherapeutics to cancer cells
Gaspar, V. M., Moreira, A. F., de Melo‐Diogo, D., Costa, E. C., Queiroz, J. A., de Sousa, F. P., Pichon, C., & Correia, I. J. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-41736-5.00006-6 · Cited by 23
Oladipo, H. J., Tajudeen, Y. A., Taiwo, E. O., Muili, A. O., Yusuf, R. O., Jimoh, S. A., Oladipo, M. K., Oladunjoye, I. O., Egbewande, O. M., Yusuff, S. I., et al. (2023) · Challenges · doi:10.3390/challe14020020 · Cited by 23
Continuous-flow DNP polarizer for MRI applications at 1.5 T
Denysenkov, V., Terekhov, M., Maeder, R., Fischer, S., Zangos, S., Vogl, T. J., & Prisner, T. F. (2017) · Scientific Reports · doi:10.1038/srep44010 · Cited by 21
In vitro toxicological assessment of gadolinium (III) chloride in V79–4 fibroblasts
Siew, E. L., Farris, A. F., Rashid, N., Chan, K. M., & Rajab, N. F. (2020) · Genes and Environment · doi:10.1186/s41021-020-00161-3 · Cited by 21
Perera, V. S., Yang, L. D., Hao, J., Chen, G., Erokwu, B. O., Flask, C. A., Zavalij, P. Y., Basilion, J. P., & Huang, S. D. (2014) · Langmuir · doi:10.1021/la501985p · Cited by 20
Ac Biosusceptometry and Magnetic Nanoparticles to Assess Doxorubicin-Induced Kidney Injury in Rats
Prospero, A. G., Oliveira, P. F., Soares, G. A., Miranda, M. F., Pinto, L. A., dos Santos, D. C., Silva, V. D. S., Zufelato, N., Bakuzis, A. F., & Miranda, J. R. D. A. (2020) · Nanomedicine · doi:10.2217/nnm-2019-0300 · Cited by 18
Contrastes basados en gadolinio utilizados en resonancia magnética
Muñoz, S. C., Blanco, C. C., Marcin, J., Álvarez, C. F., & Martínez, J. L. (2014) · Radiología · doi:10.1016/j.rx.2014.06.005 · Cited by 19
Tenorio-Jiménez, C., Valdivieso, A. M., Gallardo, G. L., & McGowan, B. M. (2011) · BMJ Case Reports · doi:10.1136/bcr.02.2011.3850 · Cited by 18
ASCI CCT & CMR Guideline Working Group, Jinzaki, M., Kitagawa, K., Tsai, I., Chan, C., Yu, W., Yong, H. S., & Choi, B. W. (2010) · International journal of cardiac imaging · doi:10.1007/s10554-010-9691-3 · Cited by 18
Spectral Computed Tomography Angiography With a Gadolinium-based Contrast Agent
Nadjiri, J., Pfeiffer, D., Straeter, A. S., Noël, P. B., Fingerle, A. A., Eckstein, H., Laugwitz, K., Rummeny, E. J., Braren, R., & Rasper, M. (2018) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000335 · Cited by 18
Carbon nanomaterials: fundamental concepts, biological interactions, and clinical applications
Chow, E. K., Gu, M., & Xu, J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816662-8.00014-x · Cited by 19
Fries, P., Maßmann, A., Robert, P., Corot, C., Laschke, M. W., Schneider, G. K., Buecker, A., & Müller, A. (2019) · Investigative Radiology · doi:10.1097/rli.0000000000000572 · Cited by 18
Gonçalves, M. A., Santos, L. D. S., Peixoto, F. C., & Ramalho, T. C. (2019) · International Journal of Quantum Chemistry · doi:10.1002/qua.25896 · Cited by 17
Cesarini, G., Spani, F., Patricelli, R., Quattrocchi, C. C., Colasanti, M., & Scalici, M. (2024) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2024.116442 · Cited by 16
Tian, M., Wen, X., Jackson, E. F., Ng, C. S., Uthamanthil, R., Liang, D., Gelovani, J. G., & Li, C. (2011) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.431 · Cited by 16
The Use of Gadolinium for Arterial Interventions
Sambol, E. B., der Meer, J. G. V., Graham, A. R., Goldstein, L. J., Karwowski, J., Dayal, R., DeRubertis, B. G., & Kent, K. C. (2011) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2010.09.012 · Cited by 15
Spasojević, B., Kotur‐Stevuljević, J., Djukić, M., Paripović, D., Miloševski‐Lomić, G., Spasojević‐Kalimanovska, V., Pavićević, P., Mitrović, J., & Kostić, M. (2017) · Medical Science Monitor · doi:10.12659/msm.903255 · Cited by 15
MR – eyes for cancer: looking within an impenetrable disease
Penet, M., Artemov, D., Farahani, K., & Bhujwalla, Z. M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2980 · Cited by 14
Advanced Contrast Agents for Multimodal Biomedical Imaging Based on Nanotechnology
Calle, D., Ballesteros, P., & Cerdán, S. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-7531-0_26 · Cited by 15
Current Status and Future Perspectives of Magnetic Resonance High-Field Imaging: A Summary
Prabhakaran, V., Nair, V. A., Austin, B. P., La, C., Gallagher, T. A., Wu, Y., McLaren, D. G., Xu, G., Turski, P. A., & Rowley, H. A. (2012) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2012.02.012 · Cited by 14
QRS-based assessment of myocardial damage and adverse events associated with cardiac sarcoidosis
Sobue, Y., Harada, M., Koshikawa, M., Ichikawa, T., Yamamoto, M., Okuda, K., Kato, Y., Sarai, M., Watanabe, E., & Ozaki, Y. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.008 · Cited by 13
Nanoparticle-based highly sensitive MRI contrast agents with enhanced relaxivity in reductive milieu
Sigg, S. J., Santini, F., Najer, A., Richard, P. U., Meier, W. P., & Palivan, C. G. (2016) · Chemical Communications · doi:10.1039/c6cc03396b · Cited by 13
Damasco, J. A., Ohulchanskyy, T. Y., Mahajan, S. D., Chen, G., Singh, A., Kutscher, H. L., Huang, H., Turowski, S. G., Spernyak, J. A., Singh, A. K., et al. (2021) · Cancer Nanotechnology · doi:10.1186/s12645-021-00075-x · Cited by 13
Toxicité rénale des produits de contraste chez le patient oncologique
Amet, S., & Deray, G. (2012) · Bulletin du Cancer · doi:10.1684/bdc.2011.1477 · Cited by 13
Accidental and iatrogenic causes of acute kidney injury
Twombley, K. E., Baum, M. G., & Gattineni, J. (2011) · Current Opinion in Pediatrics · doi:10.1097/mop.0b013e328343cd16 · Cited by 13
Tansi, F. L., Rüger, R., Kollmeier, A. M., Böhm, C., Kontermann, R. E., Teichgraeber, U. K., Fahr, A., & Hilger, I. (2017) · BMC Biotechnology · doi:10.1186/s12896-017-0327-8 · Cited by 13
Etiology, Pathogenesis, and Management of Renal Failure
Goldfarb, D. A., & Poggio, E. D. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6911-9.00044-x · Cited by 13
Zhang, K., Zocher, A.-L., & Bau, M. (2024) · Chemosphere · doi:10.1016/j.chemosphere.2024.143069 · Cited by 12
Insights into Non‐Metallic Magnetic Resonance Imaging Contrast Agents: Advances and Perspectives
Wang, Y., Ma, X., Zhang, Y., Yang, Y., Wang, P., Chen, T., Gao, C., Chen, D., Zheng, J., & Wu, A. (2025) · Small · doi:10.1002/smll.202411875 · Cited by 12
Naito, S., Tazaki, H., Okamoto, T., Takeuchi, K., Kan, S., Takeuchi, Y., & Kamata, K. (2017) · The Journal of Toxicological Sciences · doi:10.2131/jts.42.379 · Cited by 12
Manuela, G.-V., Ceballos, M. T., Urquijo, J. P., Torres, E. Y., Ortíz-Reyes, B., Arnache, O., & López, M. R. (2019) · Cellular Immunology · doi:10.1016/j.cellimm.2019.03.005 · Cited by 12
Perrin, T., Descombes, É., & Cook, S. (2012) · reroDoc Digital Library · Cited by 12
Nanotheranostics and theranostic nanomedicine for diseases and cancer treatment
Enrico, C. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813669-0.00002-6 · Cited by 12
Quantitative Body DW-MRI Biomarkers Uncertainty Estimation Using Unscented Wild-Bootstrap
Freiman, M., Voss, S. D., Mulkern, R. V., Pérez-Rosselló, J. M., & Warfield, S. K. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_10 · Cited by 12
Measurement of kidney perfusion in critically ill Patients
Schneider, A. G., Goodwin, M. D., & Bellomo, R. (2009) · Critical Care · doi:10.1186/cc1259 · Cited by 11
Knoepp, F., Bettmer, J., & Fronius, M. (2017) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2017.02.019 · Cited by 9
Mohammadi, E., Amanlou, M., Sadat-Ebrahimi, S. E., Hamedani, M. P., Mahrooz, A., Mehravi, B., Emami, B. A., Aghasadeghi, M. R., Bitarafan‐Rajabi, A., Akbar, H. R. P. A., et al. (2014) · RSC Advances · doi:10.1039/c4ra05596a · Cited by 10
Evaluation of Tongue Cancer Using High‐Resolution Sonography
Dhoot, N. M., Hazarika, S., Choudhury, B., Kataki, A. C., Baruah, R., & Goswami, H. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.14.09001 · Cited by 10
Davis, P. W., Krisanapan, P., Tangpanithandee, S., Thongprayoon, C., Miao, J., Hassanein, M., Acharya, P. C., Mao, M. A., Craici, I. M., & Cheungpasitporn, W. (2023) · Medicines · doi:10.3390/medicines10080046 · Cited by 9
Panicker, S., Wilseck, Z. M., Lin, L. Y., & Gemmete, J. J. (2024) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2024.01.004 · Cited by 9
Update on the management of chronic kidney disease.
Rivera, J. A., O’Hare, A. M., & Harper, G. M. (2012) · PubMed · Cited by 9
Miyake, Y., Kimura, Y., Ishikawa, S., Tsujita, H., Miura, H., Narazaki, M., Matsuda, T., Tabata, Y., Yano, T., Toshimitsu, A., et al. (2012) · Tetrahedron Letters · doi:10.1016/j.tetlet.2012.06.072 · Cited by 9
Abdel-Kader, K. F. M., Patel, P. R., Kallen, A. J., Sinkowitz‐Cochran, R. L., Bolton, W. K., & Unruh, M. L. (2010) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00140110 · Cited by 9
Kurzfassung der S2k-Leitlinie Erkrankungen der Nierenarterie
Oberhuber, A., Hupp, T., Richter, G. M., Nitzsche, E. U., Radermacher, J., Rump, L. C., & Vonend, O. (2019) · Gefässchirurgie · doi:10.1007/s00772-019-0520-2 · Cited by 8
Introductory Chemistry: A Molar Relaxivity Experiment in the High School Classroom
Dawsey, A. C., Hathaway, K. L., Kim, S., & Williams, T. J. (2013) · Journal of Chemical Education · doi:10.1021/ed3006902 · Cited by 8
Mawad, H., Laurin, L., Naud, J.-F., Leblond, F. A., Henley, N., Vallée, M., Pichette, V., & Leblanc, M. (2016) · Biomarker Insights · doi:10.4137/bmi.s39199 · Cited by 8
Diseases of collagen and elastic tissue
Wang, W., & Lazar, A. J. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-5649-2.00021-4 · Cited by 8
Vascular Disorders of the Kidney
DuBose, T. D., & dos Santos, R. M. (2012) · Goldman's Cecil Medicine · doi:10.1016/b978-1-4377-1604-7.00127-5 · Cited by 8
Fedotov, A. E., Kurakin, I. S., Fischer, S., Vogl, T. J., Prisner, T. F., & Denysenkov, V. (2020) · Magnetic Resonance · doi:10.5194/mr-1-275-2020 · Cited by 7
Miyake, Y., Kimura, Y., Orito, N., Imai, H., Matsuda, T., Toshimitsu, A., & Kondo, T. (2015) · Tetrahedron · doi:10.1016/j.tet.2015.04.050 · Cited by 7
Miyake, Y., Ishikawa, S., Kimura, Y., Son, A., Imai, H., Matsuda, T., Yamada, H., Toshimitsu, A., & Kondo, T. (2015) · Sensors · doi:10.3390/s151229900 · Cited by 7
Congenital Urinary Obstruction
Peters, C. A., & Chevalier, R. L. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6911-9.00113-4 · Cited by 7
Mbundi, L., Meikle, S. T., Busquets, R., Dowell, N. G., Cercignani, M., & Santin, M. (2018) · Nanomaterials · doi:10.3390/nano8060399 · Cited by 7
Hasjim, B. J., Fujitani, R. M., Chen, S. L., Donayre, C. E., Kuo, I. J., Raza, A., Reddy, U. G., Ichii, H., & Kabutey, N.-K. (2019) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2019.11.009 · Cited by 7
Pharmakokinetik von gadoliniumhaltigen Kontrastmitteln
Czock, D. (2019) · Der Radiologe · doi:10.1007/s00117-019-0496-7 · Cited by 7
None, N. (2017) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-13-3-172 · Cited by 7
Sethi, A. N., Kohli, J., Patel, A. M., & Rudnick, M. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-47871-7.00022-8 · Cited by 7
Lanaro, R., Capitani, E. M. D., Costa, J. L., Bucaretchi, F., Togni, L. R., Linden, R., Barbosa, F., Tessaro, E. P., Bataglion, G. A., Eberlin, M. N., et al. (2014) · Forensic Toxicology · doi:10.1007/s11419-014-0231-z · Cited by 7
CMR versus SPECT for diagnosis of coronary heart disease
Watkins, S., Berry, C., & Oldroyd, K. G. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60935-0 · Cited by 7
CMR versus SPECT for diagnosis of coronary heart disease
Flotats, A., Bengel, F. M., Knuuti, J. M., Guludec, D. L., & Marcassa, C. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60936-2 · Cited by 7
Kwon, C., Kang, K. M., Choi, Y. H., Yoo, R., Sohn, C., Han, S. S., & Yoon, S. H. (2021) · Korean Journal of Radiology · doi:10.3348/kjr.2020.1153 · Cited by 6
Quantitative analysis of cytokine-induced vascular toxicity and vascular leak in the mouse brain
Irwan, Y. Y., Feng, Y., Gach, H. M., Symanowski, J. T., McGregor, J. R., Veni, G., Schabel, M. C., & Samlowski, W. E. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.07.014 · Cited by 6
The prominent role of cardiac magnetic resonance imaging in coronary artery disease
Palios, J., Karangelis, D., Roubelakis, A., & Lerakis, S. (2014) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.2014.877344 · Cited by 6
Magnetic Nanoparticles for Magnetic Resonance Imaging Contrast Agents
Lee, N., & Hyeon, T. (2019) · Cambridge University Press eBooks · doi:10.1017/9781139381222.008 · Cited by 6
Patel, A. M., & Rudnick, M. R. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-3362-2.00023-3 · Cited by 6
Nephrogene systemische Fibrose
Kielstein, J. T., & Schiffer, M. (2009) · Der Internist · doi:10.1007/s00108-009-2408-9 · Cited by 6
Kim, I. Y., Lee, S. B., Lee, D. W., Song, S. H., Seong, E. Y., & Kwak, I. S. (2012) · Clinical and Experimental Nephrology · doi:10.1007/s10157-012-0629-z · Cited by 6
Du, T., Luo, H., Song, H., Lin, T., & Yu, Q. (2025) · International Journal of Oncology · doi:10.3892/ijo.2025.5776 · Cited by 5
Huang, K., Li, M., Zhang, X., Linghu, X., Wang, Y., Li, W., Wu, P., Dong, J., Yang, S., & Jiao, J. (2026) · Science China Chemistry · doi:10.1007/s11426-025-3181-8 · Cited by 5
Sungur, M. A. (2013) · Medical Science Monitor · doi:10.12659/msm.889579 · Cited by 5
Contrast-Induced Nephropathy: Current practice
Gupta, S. (2018) · Journal of Urology & Nephrology Studies · doi:10.32474/juns.2018.01.000103 · Cited by 5
Li, C., Li, C., Zhou, J. H., Wang, Y., Wu, H., Xu, L., Li, Y., Sui, X., Jiang, G., Li, Y., et al. (2024) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.3c01137 · Cited by 5
Le pied diabétique : place de la chirurgie orthopédique
Besse, J., Leemrijse, T., & Deleu, P. (2011) · Revue de Chirurgie Orthopédique et Traumatologique · doi:10.1016/j.rcot.2011.03.007 · Cited by 5
de Laforcade, L., Bobot, M., Bellin, M., Clémеnt, O., Grangé, S., Grenier, N., Wynckel, A., & Guerrot, D. (2021) · Néphrologie & Thérapeutique · doi:10.1016/j.nephro.2020.10.011 · Cited by 6
Galati, M., Marco, G. D., Falvo, S., Billè, B., Corte, C. L., Terranova, M., Crea, F., Zaffino, G., Parisi, M. G., Stefano, C. D., et al. (2026) · Environmental Research · doi:10.1016/j.envres.2026.124017 · Cited by 4
Polymeric 1H MRI Probes for Visualizing Tumor In Vivo
Kondo, T., Kimura, Y., Yamada, H., & Aoyama, Y. (2017) · The Chemical Record · doi:10.1002/tcr.201600144 · Cited by 4
Sphingomyelinase-responsive nanomicelles for targeting atherosclerosis
Muñoz-Hernando, M., Nogales, P., Fernández‐Barahona, I., Ruı́z-Cabello, J., Bentzon, J. F., & Herranz, F. (2024) · Nanoscale · doi:10.1039/d3nr06507c · Cited by 4
Toward In Vivo MRI of the Tissue Proton Exchange Rate in Humans
Shaghaghi, M., & Cai, K. (2022) · Biosensors · doi:10.3390/bios12100815 · Cited by 4
Non-contrast renal MRA using multi-shot gradient echo EPI at 3-T MRI
Morita, K., Nakaura, T., Yoneyama, M., Nagayama, Y., Kidoh, M., Uetani, H., Ikeda, O., Yamashita, Y., & Hirai, T. (2021) · European Radiology · doi:10.1007/s00330-020-07653-4 · Cited by 4
Bae, H., Oh, H., Park, G. B., & Chung, Y. E. (2024) · Korean Journal of Radiology · doi:10.3348/kjr.2023.0712 · Cited by 3
Pinto, T. G., Dedivitis, R. A., & Ribeiro, D. A. (2025) · Journal of Applied Toxicology · doi:10.1002/jat.4814 · Cited by 3
Pomann, G., Sweeney, E. M., Reich, D. S., Staicu, A., & Shinohara, R. T. (2015) · Statistics in Medicine · doi:10.1002/sim.6520 · Cited by 3
Olmaz, R., Turgutalp, K., Oğuz, E. G., Horoz, M., Özhan, O., Muşlu, N., Sungur, M. A., & KIYKIM, A. A. (2012) · Acta Radiologica · doi:10.1258/ar.2012.120434 · Cited by 3
Guranda, M., Essig, M., Poulin, A., & Vosoughi, R. (2017) · International Journal of MS Care · doi:10.7224/1537-2073.2016-053 · Cited by 3
Measurement of Kidney Perfusion in Critically Ill Patients
Schneider, A. G., Goodwin, M. D., & Bellomo, R. (2013) · Springer eBooks · doi:10.1007/978-3-642-35109-9_51 · Cited by 3
Rationales Vorgehen bei Nierenarterienstenose
Radermacher, J. (2014) · Der Nephrologe · doi:10.1007/s11560-014-0873-1 · Cited by 3
Metadata
- Authors
- Perazella, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Perazella, Mark A.
- ORCID
- Perazella, Mark A.
- Venue
- Clinical Journal of the American Society of Nephrology
- Published
- 2009-02
- Volume
- 4
- Issue
- 2
- Pages
- 461-469
- ISSN
- 1555-9041 (ISSN-L)
- OpenAlex
- W2116878814
- Cited by
- 275
- References
- 42
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 8 · 2023: 7 · 2022: 17 · 2021: 16 · 2020: 7 · 2019: 21 · 2018: 22 · 2017: 23 · 2016: 12 · 2015: 18 · 2014: 15 · 2013: 17 · 2012: 29
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Journal of the American Society of Nephrology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Society of Nephrology
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
- Keywords
- gadolinium-based contrast agents, nephrogenic systemic fibrosis, nephrotoxicity, chronic kidney disease, acute kidney injury, MRI contrast safety
- MeSH terms
- Animals, Contrast Media, Dose-Response Relationship, Drug, Gadolinium, Humans, Kidney Diseases, Magnetic Resonance Imaging, Risk Factors, Risk Assessment, Evidence-Based Medicine, Nephrogenic Fibrosing Dermopathy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review