The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Current Status of Gadolinium Toxicity in Patients with Kidney Disease
Abstract
Gadolinium-based contrast (GBC) agents have recently been the subject of intense interest for physicians across numerous specialties. These agents are widely used as contrast for magnetic resonance imaging and have been generally considered safe. Early on, phase III trials and small studies in low-risk patients suggested a benign renal profile; however, more recent studies raised the possibility of nephrotoxicity, although it is not clear whether it approaches the incidence of nephropathy associated with iodinated radiocontrast. In 2006, reports of a rare systemic fibrosing condition called nephrogenic systemic fibrosis (NSF) were recently linked to exposure of patients with advanced kidney disease to GBC agents. Analysis of the data suggests that certain GBC agents are more likely to be associated with NSF. Also, not all patients with kidney disease are at risk for developing NSF, only those with advanced acute or chronic kidney disease. Avoidance of GBC exposure is the best approach for high-risk patients. When GBC is required to obtain optimal images, use of low dosages of more stable macrocyclic agents is safer and preferred. This article reviews the current status of GBC agents as nephrotoxins and causes of NSF and provides opinions on how to use these agents in patients with underlying kidney disease.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ever more evidence is accumulating that gadolinium-based contrast enhancement agents induce nephrogenic systemic fibrosis (NSF) in patients with underlying kidney disease. As a consequence, gadolinium-based contrast agents are contraindicated in patients with impaired renal function [187].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [187]
Citations
Cites
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,862
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,398
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,011
Gadodiamide-Associated Nephrogenic Systemic Fibrosis: Why Radiologists Should Be Concerned
Broome, D. R., Girguis, M. S., Baron, P. W., Cottrell, A. C., Kjellin, I. B., & Kirk, G. A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1094 · Cited by 599
Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis
High, W. A., Ayers, R. A., Chandler, J. P., Zito, G., & Cowper, S. E. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.10.047 · Cited by 542
Nephrogenic Fibrosing Dermopathy
Cowper, S. E., Su, L. D., Bhawan, J., Robin, H. S., & LeBoit, P. E. (2001) · American Journal of Dermatopathology · doi:10.1097/00000372-200110000-00001 · Cited by 473
Nephrotoxicity of high‐dose gadolinium compared with iodinated contrast
Prince, M. R., Arnoldus, C. L., & Frisoli, J. K. (1996) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880060129 · Cited by 401
Gadolinium deposition in nephrogenic fibrosing dermopathy
Boyd, A. S., Zic, J. A., & Abraham, J. L. (2006) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.10.048 · Cited by 374
Nephrogenic systemic fibrosis: a serious late adverse reaction to gadodiamide
Thomsen, H. S. (2006) · European Radiology · doi:10.1007/s00330-006-0495-8 · Cited by 352
Collidge, T., Thomson, P. C., Mark, P. B., Traynor, J. P., Jardine, A. G., Morris, S., Simpson, K., & Roditi, G. (2007) · Radiology · doi:10.1148/radiol.2451070353 · Cited by 319
Flagged first, then by citations
Cited by
Sorted by citations
Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications
Dadfar, S. M., Roemhild, K., Drude, N. I., von Stillfried, S., Knüchel, R., Kiessling, F., & Lammers, T. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.01.005 · Cited by 1,181
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2012) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,150
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,084
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch‐Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 822
Upconverting nanoparticles: assessing the toxicity
Gnach, A., Lipiński, T., Bednarkiewicz, A., Rybka, J., & Capobianco, J. A. (2014) · Chemical Society Reviews · doi:10.1039/c4cs00177j · Cited by 663
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch‐Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 591
Gadolinium‐based contrast agents for magnetic resonance cancer imaging
Zhou, Z., & Lu, Z. (2012) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1198 · Cited by 431
Clinical Practice Guideline: Ménière’s Disease
Basura, G. J., Adams, M. E., Monfared, A. S., Schwartz, S., Antonelli, P. J., Burkard, R., Bush, M. L., Bykowski, J., Colandrea, M., Derebery, J. M., et al. (2020) · Otolaryngology · doi:10.1177/0194599820909438 · Cited by 392
Iron Oxide Nanoparticle Based Contrast Agents for Magnetic Resonance Imaging
Shen, Z., Wu, A., & Chen, X. S. (2016) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.6b00839 · Cited by 335
Shokouhimehr, M., Soehnlen, E. S., Hao, J., Griswold, M. A., Flask, C. A., Fan, X., Basilion, J. P., Basu, S., & Huang, S. D. (2010) · Journal of Materials Chemistry · doi:10.1039/b923184f · Cited by 266
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B. R., Lamm, D. L., O’Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 255
Repurposing ferumoxytol: Diagnostic and therapeutic applications of an FDA-approved nanoparticle
Huang, Y., Hsu, J. C., Koo, H., & Cormode, D. P. (2021) · Theranostics · doi:10.7150/thno.67375 · Cited by 265
Lee, N., Cho, H. R., Oh, M. H., Lee, S. H., Kim, K. M., Kim, B. H., Shin, K., Ahn, T.-Y., Choi, J. W., Kim, Y., et al. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3016582 · Cited by 238
Lameire, N. H., Kellum, J. A., & for the KDIGO AKI Guideline Work Group (2013) · Critical Care · doi:10.1186/cc11455 · Cited by 220
Impact of Lanthanide Nanomaterials on Photonic Devices and Smart Applications
Zhou, J., Leaño, J. L., Liu, Z., Jin, D., Wong, K., Liu, R., & Bünzli, J. G. (2018) · Small · doi:10.1002/smll.201801882 · Cited by 166
Large‐Scale Synthesis and Medical Applications of Uniform‐Sized Metal Oxide Nanoparticles
Kwon, H. J., Shin, K., Soh, M., Chang, H., Kim, J., Lee, J., Ko, G., Kim, B. H., Kim, D., & Hyeon, T. (2018) · Advanced Materials · doi:10.1002/adma.201704290 · Cited by 163
Macromolecular Ligands for Gadolinium MRI Contrast Agents
Li, Y., Beija, M., Laurent, S., Elst, L. V., Müller, R. N., Duong, H. T. T., Lowe, A. B., Davis, T. P., & Boyer, C. A. (2012) · Macromolecules · doi:10.1021/ma300521c · Cited by 155
Mi, P., Dewi, N., Yanagië, H., Kokuryo, D., Suzuki, M., Sakurai, Y., Li, Y., Aoki, I., Ono, K., Takahashi, H., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b00532 · Cited by 141
Contrast-induced acute kidney injury: A review of practical points
Özkök, S., & Özkök, A. (2017) · World Journal of Nephrology · doi:10.5527/wjn.v6.i3.86 · Cited by 139
Progress and prospects of magnetic iron oxide nanoparticles in biomedical applications: A review
Elahi, N., & Rizwan, M. (2021) · Artificial Organs · doi:10.1111/aor.14027 · Cited by 130
Gadolinium-Based Contrast Agent Use, Their Safety, and Practice Evolution
Do, C., DeAguero, J., Brearley, A., Trejo, X., Howard, T., Escobar, G. P., & Wagner, B. (2020) · Kidney360 · doi:10.34067/kid.0000272019 · Cited by 125
Davies, J., Siebenhandl-Wolff, P., Tranquart, F., Jones, P. A., & Evans, P. M. (2022) · Archives of Toxicology · doi:10.1007/s00204-021-03189-8 · Cited by 123
Recent development of nanoparticles for molecular imaging
Kim, J., Lee, N., & Hyeon, T. (2017) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2017.0022 · Cited by 116
Functional nanoparticles for magnetic resonance imaging
Mao, X., Xu, J., & Cui, H. (2016) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1400 · Cited by 115
Baranyai, Z., Pálinkás, Z., Uggeri, F., Maiocchi, A., Aime, S., & Brücher, E. (2012) · Chemistry - A European Journal · doi:10.1002/chem.201202930 · Cited by 109
Knuuti, J. M., Bengel, F. M., Bax, J. J., Kaufmann, P. A., Guludec, D. L., Filardi, P. P., Marcassa, C., Marsan, N. A., Achenbach, S. S., Kitsiou, A. N., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht512 · Cited by 107
Advanced metal and carbon nanostructures for medical, drug delivery and bio-imaging applications
Kumar, N., Chamoli, P., Misra, M., Manoj, M. K., & Sharma, A. (2022) · Nanoscale · doi:10.1039/d1nr07643d · Cited by 100
Nosrati, H., Salehiabar, M., Fridoni, M., Abdollahifar, M., Manjili, H. K., Davaran, S., & Danafar, H. (2019) · Scientific Reports · doi:10.1038/s41598-019-43650-4 · Cited by 96
Iron Oxide Nanoparticles in Bioimaging – An Immune Perspective
Geppert, M., & Himly, M. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.688927 · Cited by 95
Peripheral artery disease. Part 1: clinical evaluation and noninvasive diagnosis
Lau, J. F., Weinberg, M. D., & Olin, J. W. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.66 · Cited by 94
Involvement of Gadolinium Chelates in the Mechanism of Nephrogenic Systemic Fibrosis: An Update
Idée, J., Port, M., Dencausse, A., Lancelot, E., & Corot, C. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2009.06.006 · Cited by 90
Hagberg, G. E., & Scheffler, K. (2013) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1565 · Cited by 89
Review of breast screening: Toward clinical realization of microwave imaging
Modiri, A., Goudreau, S., Rahimi, A. S., & Kıasaleh, K. (2017) · Medical Physics · doi:10.1002/mp.12611 · Cited by 87
Hanana, H., Turcotte, P., André, C., Gagnon, C., & Gagné, F. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.04.073 · Cited by 82
Nguyen, H. V. ‐., Detappe, A., Gallagher, N. M., Zhang, H., Harvey, P., Yan, C., Mathieu, C., Golder, M. R., Jiang, Y., Ottaviani, M. F., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b06160 · Cited by 81
Safety Report of Ferumoxytol for Magnetic Resonance Imaging in Children and Young Adults
Muehe, A. M., Feng, D., von Eyben, R., Luna‐Fineman, S., Link, M. P., Muthig, T., Huddleston, A. E., Neuwelt, E. A., & Daldrup-Link, H. E. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000230 · Cited by 80
Gorris, H. H., & Resch‐Genger, U. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0482-8 · Cited by 77
Functional polymers as metal-free magnetic resonance imaging contrast agents
Fu, C., Yu, Y., Xu, X., Wang, Q., Chang, Y.-X., Zhang, C., Zhao, J., Peng, H., & Whittaker, A. K. (2020) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2020.101286 · Cited by 76
Section 4: Contrast-induced AKI
(2012) · Kidney International Supplements · doi:10.1038/kisup.2011.34 · Cited by 69
Nosrati, H., Tarantash, M., Bochani, S., Charmi, J., Bagheri, Z., Fridoni, M., Abdollahifar, M., Davaran, S., Danafar, H., & Manjili, H. K. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b01420 · Cited by 66
Importance of monitoring renal function in patients with cancer
Aapro, M., & Launay‐Vacher, V. (2011) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2011.05.001 · Cited by 64
Gonçalves, M. A., Santos, L. D. S., Prata, D. M., Peixoto, F. C., da Cunha, E. F. F., & Ramalho, T. C. (2016) · Theoretical Chemistry Accounts · doi:10.1007/s00214-016-2037-z · Cited by 65
Lai, Y., Su, C.-Y., Cheng, H., Chu, C., Jeng, L., Chiang, C., Shyu, W., & Chen, S. (2023) · Nature Communications · doi:10.1038/s41467-023-35935-0 · Cited by 69
Photoacoustic computed tomography of human extremities
Wray, P. R., Lin, L., Hu, P., & Wang, L.-H. V. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.2.026003 · Cited by 62
Hsu, J. C., Naha, P. C., Lau, K. C., Chhour, P., Hastings, R., Moon, B. F., Stein, J. M., Witschey, W. R. T., McDonald, E. S., Maidment, A. D. A., et al. (2018) · Nanoscale · doi:10.1039/c8nr03741h · Cited by 63
(2012) · Kidney International Supplements · doi:10.1038/kisup.2012.67 · Cited by 62
Nanomedical Theranostics in Cardiovascular Disease
Tang, J., Lobatto, M. E., Read, J. C., Mieszawska, A. J., Fayad, Z. A., & Mulder, W. J. M. (2011) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-011-9120-6 · Cited by 60
Blood‐Pool and Targeting MRI Contrast Agents: From Gd‐Chelates to Gd‐Nanoparticles
Lee, G. H., Chang, Y., & Kim, T. (2012) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201101137 · Cited by 57
Zhou, Z., & Lu, Z. (2014) · Nanomedicine · doi:10.2217/nnm.14.133 · Cited by 57
Applications of Molecular Mri and Optical Imaging in Cancer
Penet, M., Mikhaylova, M., Li, C., Krishnamachary, B., Glunde, K., Pathak, A. P., & Bhujwalla, Z. M. (2010) · Future Medicinal Chemistry · doi:10.4155/fmc.10.25 · Cited by 56
Kumbhar, P. R., Kumar, P., Lasure, A., Ravichandiran, V., & Mandal, D. (2023) · Discover Nano · doi:10.1186/s11671-023-03913-6 · Cited by 60
Fretellier, N., Idée, J., Guérret, S., Hollenbeck, C., Hartmann, D. J., González, W., Pujolle-Robic, C., Port, M., & Corot, C. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181f54044 · Cited by 55
Li, Y., Duong, H. T. T., Laurent, S., MacMillan, A., Whan, R. M., Elst, L. V., Müller, R. N., Hu, J., Lowe, A. B., Boyer, C. A., et al. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201400164 · Cited by 54
Type of MRI contrast, tissue gadolinium, and fibrosis
Do, C., Barnes, J. L., Tan, C., & Wagner, B. (2014) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00379.2014 · Cited by 53
PVP‐coated Gd‐grafted nanodiamonds as a novel and potentially safer contrast agent for in vivo MRI
Panich, A. M., Salti, M., Prager, O., Swissa, E., Kulvelis, Y. V., Yudina, E. B., Aleksenskii, A. E., Goren, S. D., Vul', A. Y., & Shames, A. I. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28762 · Cited by 53
Golnabi, A. H., Meaney, P. M., Geimer, S. D., & Paulsen, K. D. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2892303 · Cited by 50
2-Dimensional Nanomaterials with Imaging and Diagnostic Functions for Nanomedicine; A Review
Eom, S., Choi, G., Nakamura, H., & Choy, J. (2019) · Bulletin of the Chemical Society of Japan · doi:10.1246/bcsj.20190270 · Cited by 50
Lingwood, M. D., Siaw, T. A., Sailasuta, N., Ross, B. D., Bhattacharya, P. K., & Han, S. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.05.008 · Cited by 48
Hyperpolarized Water as an MR Imaging Contrast Agent: Feasibility of in Vivo Imaging in a Rat Model
Lingwood, M. D., Siaw, T. A., Sailasuta, N., Abulseoud, O. A., Chan, H. R., Ross, B. D., Bhattacharya, P. K., & Han, S. (2012) · Radiology · doi:10.1148/radiol.12111804 · Cited by 48
Oluwasola, E. I., Ahmad, A. L., Shoparwe, N. F., & Ismail, S. B. (2022) · Journal of Contaminant Hydrology · doi:10.1016/j.jconhyd.2022.104057 · Cited by 48
Current concepts of contrast-induced nephropathy: A brief review
Chang, C.-F., & Lin, C. (2013) · Journal of the Chinese Medical Association · doi:10.1016/j.jcma.2013.08.011 · Cited by 47
Li, Y., Laurent, S., Esser, L., Elst, L. V., Müller, R. N., Lowe, A. B., Boyer, C. A., & Davis, T. P. (2013) · Polymer Chemistry · doi:10.1039/c3py01676e · Cited by 47
Chen, T., Liu, L., Ma, X., Zhang, Y., Liu, H., Zheng, R., Ren, J., Zhou, H., Ren, Y., Gao, R., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3113764 · Cited by 46
Gadolinium toxicity: mechanisms, clinical manifestations, and nanoparticle role
Domingo, J. L., & Semelka, R. C. (2025) · Archives of Toxicology · doi:10.1007/s00204-025-04124-x · Cited by 44
Gadolinium-Induced Nephrogenic Systemic Fibrosis
Hellman, R. N. (2011) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2011.05.010 · Cited by 42
Adverse Reactions to Gadoterate Meglumine
de Kerviler, É., Maravilla, K. R., Méder, J.-F., Naggara, O. N., Dubourdieu, C., Jullien, V., & Desché, P. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000276 · Cited by 42
de Laforcade, L., Bobot, M., Bellin, M., Clémеnt, O., Grangé, S., Grenier, N., Wynckel, A., & Guerrot, D. (2021) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2021.01.007 · Cited by 44
Gadolinium-Based Contrast Agents: Updates and Answers to Typical Questions Regarding Gadolinium Use
Cheong, B., Wilson, J. M., Preventza, O. A., & Muthupillai, R. (2022) · Texas Heart Institute Journal · doi:10.14503/thij-21-7680 · Cited by 40
Chapter 5: Referral to specialists and models of care
(2012) · Kidney International Supplements · doi:10.1038/kisup.2012.68 · Cited by 42
(2012) · Kidney International Supplements · doi:10.1038/kisup.2012.72 · Cited by 39
Shao, X., Zhao, C., Shou, Q., Lawrence, K. S., & Wang, D. J. J. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29581 · Cited by 37
Measurement of kidney perfusion in critically ill Patients
Schneider, A. G., Goodwin, M. D., & Bellomo, R. (2013) · Critical Care · doi:10.1186/cc12529 · Cited by 36
Optical and Magnetic Resonance Imaging Using Fluorous Colloidal Nanoparticles
Wallat, J. D., Czapar, A. E., Wang, C. Y., Wen, A. M., Wek, K. S., Yu, X., Steinmetz, N. F., & Pokorski, J. K. (2016) · Biomacromolecules · doi:10.1021/acs.biomac.6b01389 · Cited by 37
Bench-to-bedside development of multifunctional flexible embolic agents
Wang, D., & Rao, W. (2023) · Theranostics · doi:10.7150/thno.80213 · Cited by 35
Tian, X., Li, H., Jiang, X., Xie, J., Gore, J. C., & Xu, J. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.11.018 · Cited by 35
Muehe, A. M., Theruvath, A. J., Lai, L. M., Aghighi, M., Quon, A. S. W., Holdsworth, S. J., Wang, J., Luna‐Fineman, S., Marina, N. M., Advani, R. H., et al. (2017) · Molecular Imaging and Biology · doi:10.1007/s11307-017-1105-7 · Cited by 35
Haylor, J., Dencausse, A., Vickers, M. E., Nutter, F., Jestin, G., Slater, D. N., Idée, J., & Morcos, S. K. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181eb51f2 · Cited by 35
Ansari, N. A. (2015) · World Journal of Radiology · doi:10.4329/wjr.v7.i11.361 · Cited by 34
Palmer, A. J. R., Fernquest, S. J., Rombach, I., Park, D., Pollard, T., Broomfield, J., Bangerter, N. K., Carr, A. J., & Glyn‐Jones, S. (2017) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2017.05.004 · Cited by 34
Takagi, H., Ota, H., Natsuaki, Y., Komori, Y., Ito, K., Saiki, Y., & Takase, K. (2015) · Japanese Journal of Radiology · doi:10.1007/s11604-015-0490-6 · Cited by 34
Integration of 3-Dimensional Scar Models from SPECT to Guide Ventricular Tachycardia Ablation
Tian, J., Smith, M. F., Ahmad, G., Dilsizian, V., Jiménez, A., & Dickfeld, T. M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.094904 · Cited by 33
Luminophore and Magnetic Multicore Nanoassemblies for Dual-Mode MRI and Fluorescence Imaging
Lartigue, L., Coupeau, M., & Lesault, M. (2019) · Nanomaterials · doi:10.3390/nano10010028 · Cited by 32
Assessment of unilateral ureter obstruction with multi‐parametric MRI
Wang, F., Takahashi, K., Li, H., Zu, Z., Li, K., Xu, J., Harris, R. C., Takahashi, T., & Gore, J. C. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26849 · Cited by 32
Imaging Shoulder Instability in the Athlete
Bergin, D. (2009) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2009.06.002 · Cited by 31
Han, S., Yoon, S. H., Lee, W., Choi, Y. H., Kang, D. Y., & Kang, H. (2018) · Korean Journal of Radiology · doi:10.3348/kjr.2017.0771 · Cited by 31
Chintamaneni, P. K., Dasari, N., Katta, C. B., Mourya, A., Madan, J., Srinivasarao, D. A., Ramachandra, R. K., Santhoshi, P. M., & Pindiprolu, S. K. S. S. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.10.056 · Cited by 32
Xiang, Y. H., Li, N., Guo, L., Wang, H., Sun, H., Li, R., Ma, L., Qi, Y., Zhan, J., & Yu, D. (2018) · Carbon · doi:10.1016/j.carbon.2018.04.058 · Cited by 31
Imaging For Renovascular Disease
O'Neill, W. C., Bardelli, M., & Yevzlin, A. S. (2011) · Seminars in Nephrology · doi:10.1016/j.semnephrol.2011.05.007 · Cited by 29
Monophosphoryl lipid A as a prophylactic for sepsis and septic shock.
Gustafson, G. L., Rhodes, M. J., & Hegel, T. (1995) · PubMed · Cited by 29
Mora‐Gutiérrez, J. M., Fernández‐Seara, M. A., Echeverría‐Chasco, R., & Garcı́a-Fernández, N. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10112461 · Cited by 29
Fries, P., Morelli, J. N., Lux, F., Tillement, O., Schneider, G. K., & Buecker, A. (2014) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1291 · Cited by 28
(2012) · Kidney International Supplements · doi:10.1038/kisup.2011.38 · Cited by 28
Predicting Breakdown of the Blood-Brain Barrier in Multiple Sclerosis without Contrast Agents
Shinohara, R. T., Goldsmith, J., Mateen, F. J., Crainiceanu, C., & Reich, D. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2997 · Cited by 27
Laurent, G., Bernhard, C., Dufort, S., Sánchez, G. J., Bazzi, R., Boschetti, F., Moreau, M., Vu, T. H., Collin, B., Oudot, A., et al. (2016) · Nanoscale · doi:10.1039/c6nr01228k · Cited by 27
Nephrogenic systemic fibrosis: A frivolous entity
Bhargava, V., Singh, K., Meena, P., & Sanyal, R. (2021) · World Journal of Nephrology · doi:10.5527/wjn.v10.i3.29 · Cited by 26
Raman needle arthroscopy for in vivo molecular assessment of cartilage
Kroupa, K. R., Wu, M. I., Zhang, J., Jensen, M., Wong, W., Engiles, J. B., Schaer, T. P., Grinstaff, M. W., Snyder, B. D., Bergholt, M. S., et al. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25155 · Cited by 26
Imaging Patients With Kidney Disease: How Do We Approach Contrast-Related Toxicity?
Perazella, M. A., & Reilly, R. F. (2010) · The American Journal of the Medical Sciences · doi:10.1097/maj.0b013e3181f016e6 · Cited by 26
Self-citationAdvanced vascular imaging techniques
Settecase, F., & Rayz, V. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64034-5.00016-x · Cited by 25
Kasper, J. Y., Hermanns, M. I., Cavelius, C., Kraegeloh, A., Jung, T., Danzebrink, R., Unger, R. E., & Kirkpatrick, C. J. (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s92608 · Cited by 29
Sawhney, S., & Wilson, S. R. (2017) · Ultrasound Quarterly · doi:10.1097/ruq.0000000000000271 · Cited by 25
Metadata
- Authors
- Perazella, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Perazella, Mark A.
- ORCID
- Perazella, Mark A.
- Venue
- Clinical Journal of the American Society of Nephrology
- Published
- 2009-02
- Volume
- 4
- Issue
- 2
- Pages
- 461-469
- ISSN
- 1555-9041 (ISSN-L)
- OpenAlex
- W2116878814
- Cited by
- 275
- References
- 42
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 8 · 2023: 7 · 2022: 17 · 2021: 16 · 2020: 7 · 2019: 21 · 2018: 22 · 2017: 23 · 2016: 12 · 2015: 18 · 2014: 15 · 2013: 17 · 2012: 29
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Journal of the American Society of Nephrology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Society of Nephrology
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
- Health Sciences › Medicine › Nephrology › Acute Kidney Injury Research
- Health Sciences › Medicine › Nephrology › Chronic Kidney Disease and Diabetes
- Keywords
- gadolinium-based contrast agents, nephrogenic systemic fibrosis, nephrotoxicity, chronic kidney disease, acute kidney injury, MRI contrast safety
- MeSH terms
- Animals, Contrast Media, Dose-Response Relationship, Drug, Gadolinium, Humans, Kidney Diseases, Magnetic Resonance Imaging, Risk Factors, Risk Assessment, Evidence-Based Medicine, Nephrogenic Fibrosing Dermopathy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review