CoChat

Carotid Intima-Media Thickness and Incident ESRD: The Atherosclerosis Risk in Communities (ARIC) Study

Open access
Pang, Yuanjie, Sang, Yingying, Ballew, Shoshana H., Grams, Morgan E., Heiss, Gerardo, Coresh, Josef, Matsushita, Kunihiro · 2016 · Clinical Journal of the American Society of Nephrology
Cited by 16

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background and objectives: Carotid intima-media thickness has been reported to predict kidney function decline. However, whether carotid intima-media thickness is associated with a hard kidney end point, ESRD, has not been investigated. Design, setting, participants, & measurements: We studied 13,197 Atherosclerosis Risk in Communities participants at visit 1 (1987–1989) without history of cardiovascular disease, including coronary heart disease, stroke, and heart failure, at baseline and assessed whether carotid intima-media thickness measured by B-mode ultrasound is associated with ESRD risk using Cox proportional hazards models. Regarding carotid intima-media thickness parameters, we investigated the mean and maximum values of overall and segment-specific (common, bifurcation, and internal carotid arteries) measurements. Results: Mean age was 54.0 (SD=5.7) years old, and there were 3373 (25.6%) blacks and 7370 (55.8%) women. During a median follow-up of 22.7 years, 433 participants developed ESRD (1.4/1000 person-years). After adjusting for shared risk factors for atherosclerosis and kidney disease, including baseline kidney function, carotid intima-media thickness was significantly associated with ESRD risk (hazard ratio [HR] between quartiles 4 and 1, 1.46; 95% confidence interval [95% CI], 1.02 to 2.08 for overall mean intima-media thickness and HR between quartiles 4 and 1, 1.75; 95% CI, 1.24 to 2.48 for overall maximum intima-media thickness). The associations were largely consistent in demographic and clinical subgroups. When we explored segment–specific intima-media thicknesses, the associations with ESRD were most robust for bifurcation carotid (e.g., adjusted HR between quartiles 4 and 1 of mean intima-media thickness, 1.49; 95% CI, 1.04 to 2.13 for bifurcation; adjusted HR between quartiles 4 and 1 of mean intima-media thickness, 1.36; 95% CI, 0.94 to 1.97 for common; and adjusted HR between quartiles 4 and 1 of mean intima-media thickness, 0.93; 95% CI, 0.67 to 1.29 for internal). Conclusions: Carotid intima-media thickness was independently associated with incident ESRD in the general population, suggesting the shared etiology of atherosclerosis and ESRD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2215/cjn.11951115

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 16

Metadata

Authors
Pang, Y., Sang, Y., Ballew, S. H., Grams, M. E., Heiss, G., Coresh, J., & Matsushita, K.
Venue
Clinical Journal of the American Society of Nephrology
Published
2016-04-12
Volume
11
Issue
7
Pages
1197-1205
ISSN
  • 1555-9041 (ISSN-L)
  • 1555-905X
OpenAlex
W2341408985
Cited by
16
References
2
FWCI
1.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.