Cited by 71Nanoparticles: synthesis and applicationsAnimal testing and alternativesGraphene and Nanomaterials Applications

Nanomaterial Cell Interactions: Are Current In Vitro Tests Reliable?

Hirsch, Cordula, Roesslein, Matthias, Krug, Harald F, Wick, Peter·2011·Nanomedicine

Abstract

New properties of engineered nanomaterials raise great expectations for industrial, scientific as well as medical applications. At the same time concerns among consumers regarding the safety aspects of this new technology emerge. Furthermore, among the multitude of published studies, a considerable number do not reveal reliable data. Thus, standardized, validated, reliable, robust, reproducible and intelligent testing strategies are urgently needed that address nanomaterial toxicity. This article discusses the reliability of currently used in vitro toxicity assays. It covers major problems, pitfalls and challenges of assay performance and validation. We recommend a series of different controls to improve the experimental quality and, thus, also the reliability and reproducibility of current in vitro systems. These recommendations consequently applied in the future will increase the safe and sustainable use of nanotechnology.

Integrity signals

Registry

Crossref · 10.2217/nnm.11.88

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Insufficient nanoparticle characterization, unidentified interference with test systems, and poor definition of controls for monitoring assay performance led to several contradictory observations in early nanotoxicology research.

    “Insufficient nanoparticle characterization, unidentified interference with test systems, and poor definition of controls for monitoring assay performance led to several contradictory observations in the early days of nanotoxicology research (Hirsch et al., 2011).”

    From In Vitro research Reproducibility: Keeping up High Standards (2019) · cites this paper as Hirsch et al., 2011

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hirsch, C., Roesslein, M., Krug, H. F., & Wick, P.
Affiliations
Empa (CH)
Venue
Nanomedicine
Published
2011-07
Volume
6
Issue
5
Pages
837-847
ISSN
  • 1743-5889 (ISSN-L)
  • 1748-6963
OpenAlex
W2025068492
Cited by
71
References
1
Citations by year
2026: 1 · 2025: 5 · 2024: 1 · 2022: 9 · 2021: 3 · 2020: 3 · 2019: 4 · 2018: 5 · 2017: 5 · 2016: 10 · 2015: 4 · 2014: 11 · 2013: 5 · 2012: 3
FWCI
0.32
Type
journal article
Language
en
Open access
closed
Locations
  • Nanomedicine (publishedVersion)
  • PubMed (publishedVersion)
  • DORA Empa (Swiss Federal Laboratories for Materials Science and Technology (Empa)) (submittedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
  • Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
  • Physical Sciences › Engineering › Biomedical Engineering › Graphene and Nanomaterials Applications
Keywords
engineered nanomaterials, nanomaterial toxicity, in vitro toxicity testing, assay validation, assay reliability, reproducibility, nanomaterial-cell interactions
MeSH terms
Animals, Cytological Techniques, Humans, Reproducibility of Results, Toxicity Tests, Nanostructures, Validation Studies as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review