Recent Advances in the Design Of Cardiovascular Materials for Biomedical Applications
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Biomaterials dominate the field of cardiovascular therapeutics, a multitude of which have been used to repair and replace injured heart tissue. This field has evolved beyond the simple selection of compatible materials and now focuses on the rational design of controlled structures that integrate with the cardiovascular system. However, the compatibility of these materials with the blood presents a major limitation to their clinical application. In this context, surface modification strategies can enhance blood compatibility and several recent advances in this area have emerged. This review summarizes the recent applications of biomaterials in cardiovascular therapies, the improvements in their biocompatibility and the surface modification technologies that have the potential to improve clinical outcomes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, PTFE coatings improve the biocompatibility of stents and orthopedic implants while minimizing biofilm formation and local tissue inflammation [16,17,18].”
From Exposure to Per- and Polyfluoroalkyl Substances (PFASs) in Healthcare: Environmental and Clinical Insights (2025) · cites this paper as [17]
Citations
Cites
A review of modified DLC coatings for biological applications
Hauert, R. (2003) · Diamond and Related Materials · doi:10.1016/s0925-9635(03)00081-5 · Cited by 681
Proangiogenic scaffolds as functional templates for cardiac tissue engineering
Madden, L. R., Mortisen, D. J., Sussman, E. M., Dupras, S. K., Fugate, J. A., Cuy, J. L., Hauch, K. D., Laflamme, M. A., Murry, C. E., & Ratner, B. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1006442107 · Cited by 662
Medical device‐induced thrombosis: what causes it and how can we prevent it?
Jaffer, I. H., Fredenburgh, J. C., Hirsh, J., & Weitz, J. I. (2015) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12961 · Cited by 557
Maron, D. J., Hochman, J. S., O’Brien, S. M., Reynolds, H. R., Boden, W. E., Stone, G. W., Bangalore, S., Spertus, J. A., Mark, D. B., Alexander, K. P., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.04.011 · Cited by 262
UV-Assisted 3D Bioprinting of Nanoreinforced Hybrid Cardiac Patch for Myocardial Tissue Engineering
Izadifar, M., Chapman, D., Babyn, P., Chen, X., & Kelly, M. E. (2018) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2017.0346 · Cited by 236
Vahabzadeh, S., Roy, M., Bandyopadhyay, A., & Bose, S. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.01.022 · Cited by 198
Biomaterials in Cardiovascular Research: Applications and Clinical Implications
Jaganathan, S. K., Supriyanto, E., Murugesan, S., Balaji, A., & Asokan, M. K. (2014) · BioMed Research International · doi:10.1155/2014/459465 · Cited by 170
Qiu, H., Qi, P., Liu, J., Yang, Y., Tan, X., Xiao, Y., Maitz, M. F., Huang, N., & Yang, Z. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.033 · Cited by 159
Biomaterial based cardiac tissue engineering and its applications
Huyer, L. D., Montgomery, M., Zhao, Y., Xiao, Y., Conant, G., Korolj, A., & Radisic, M. (2015) · Biomedical Materials · doi:10.1088/1748-6041/10/3/034004 · Cited by 145
Micro- and nano-patterned conductive graphene–PEG hybrid scaffolds for cardiac tissue engineering
Smith, A. S. T., Yoo, H., Yi, H., Ahn, E. H., Lee, J. H., Shao, G., Nagornyak, E., Laflamme, M. A., Murry, C. E., & Kim, D.-H. (2017) · Chemical Communications · doi:10.1039/c7cc01988b · Cited by 113
Sakamoto, A., Jinnouchi, H., Torii, S., Virmani, R., & Finn, A. V. (2018) · Bioengineering · doi:10.3390/bioengineering5030071 · Cited by 110
de Winter, R. J., Katagiri, Y., Asano, T., Milewski, K. P., Lurz, P. C., Buszman, P. E., Jessurun, G. A. J., Koch, K. T., Troquay, R. P. T., Hamer, B., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)33103-3 · Cited by 105
Induction plasma sprayed Sr and Mg doped nano hydroxyapatite coatings on Ti for bone implant
Roy, M., Bandyopadhyay, A. K., & Bose, S. (2011) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31893 · Cited by 103
Cohen, D. J., Osnabrugge, R. L. J., Magnuson, E. A., Wang, K., Li, H., Chinnakondepalli, K., Pinto, D. S., Abdallah, M., Vilain, K. R., Morice, M., et al. (2014) · Circulation · doi:10.1161/circulationaha.114.009985 · Cited by 96
Beating-Heart Mitral Valve Repair Using a Novel ePTFE Cordal Implantation Device
Gammie, J. S., Bartuś, K., Gackowski, A., DʼAmbra, M. N., Szymański, P., Bilewska, A., Kuśmierczyk, M., Kapelak, B., Rzucidło-Resil, J., Moat, N. E., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.062 · Cited by 94
Perea‐Gil, I., Uriarte, J. J., Prat‐Vidal, C., Gálvez‐Montón, C., Roura, S., Valldeperas, A. L., Soler‐Botija, C., Farré, R., Navajas, D., & Bayés‐Genís, A. (2015) · PubMed · Cited by 80
Oyagbemi, A. A., Omóbòwálé, T. O., Awoyomi, O., Ajibade, T., Falayi, O. O., Ogunpolu, B. S., Okotie, U. J., Asenuga, E. R., Adejumobi, O. A., Hassan, F., et al. (2018) · Human & Experimental Toxicology · doi:10.1177/0960327118812158 · Cited by 74
Clinical outcomes of silicon carbide coated stents in patients with coronary artery disease.
Kalnins, U., Ērglis, A., Dinne, I., Kumsārs, I., & Jēgere, S. (2002) · PubMed · Cited by 72
Self‐Folded Hydrogel Tubes for Implantable Muscular Tissue Scaffolds
Vannozzi, L., Yasa, I. C., Ceylan, H., Menciassi, A., Ricotti, L., & Sitti, M. (2018) · Macromolecular Bioscience · doi:10.1002/mabi.201700377 · Cited by 71
Li, T., Liang, W., Xiao, X., & Qian, Y. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s179678 · Cited by 66
Dalgliesh, A. J., Parvizi, M., Lopera-Higuita, M., Shklover, J., & Griffiths, L. G. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.016 · Cited by 57
Nanotechnology Approaches in Tackling Cardiovascular Diseases
Prajnamitra, R. P., Chen, H.-C., Lin, C., Chen, L.-L., & Hsieh, P. C. H. (2019) · Molecules · doi:10.3390/molecules24102017 · Cited by 56
Bioengineered tissue solutions for repair, correction and reconstruction in cardiovascular surgery
Iop, L., Palmosi, T., Dal Sasso, E., & Gerosa, G. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.04.27 · Cited by 50
Han, C., Luo, X., Zou, D., Li, J., Zhang, K., Yang, P., & Huang, N. (2019) · Biomaterials Science · doi:10.1039/c9bm00128j · Cited by 48
Magmaris™ Resorbable Magnesium Scaffold: state-of-art Review
Cerrato, E., Barbero, U., Romero, J. A. G., Quadri, G., Mejía-Rentería, H. D., Tomassini, F., Ferrari, F., Varbella, F., Gonzalo, N., & Escaned, J. (2019) · Future Cardiology · doi:10.2217/fca-2018-0081 · Cited by 48
Patnaik, S. S., Simionescu, D. T., Goergen, C. J., Hoyt, K., Sirsi, S. R., & Finol, E. A. (2018) · Annals of Biomedical Engineering · doi:10.1007/s10439-018-02145-5 · Cited by 47
On-X Valve: The Next Generation Aortic Valve
Chaudhary, R., Garg, J., Krishnamoorthy, P. M., Shah, N. N., Feldman, B. A., Martinez, M. W., & Freudenberger, R. S. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000105 · Cited by 44
Aleksieva, G., Hollweck, T., Thierfelder, N., Haas, U., König, F., Fano, C., Dauner, M., Wintermantel, E., Reichart, B., Schmitz, C., et al. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-92 · Cited by 37
Zou, D., Luo, X., Han, C., Li, J., Yang, P., Li, Q., & Huang, N. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.11.078 · Cited by 35
Kufner, S., Schacher, N., Ferenc, M., Schlundt, C., Hoppmann, P., Abdel‐Wahab, M., Mayer, K., Fusaro, M., Byrne, R. A., & Kastrati, A. (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27979 · Cited by 32
3D printing and biocompatibility study of a new biodegradable occluder for cardiac defect
Sun, Y., Zhang, X., Li, W., Di, Y., Xing, Q., & Cao, Q. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.02.002 · Cited by 25
Wu, J., Li, J., Wu, F., He, Z., Yang, P., & Huang, N. (2015) · Biointerphases · doi:10.1116/1.4928304 · Cited by 23
Rodés‐Cabau, J., Jolly, S. S., Cairns, J. A., Mansour, S., L’Allier, P. L., Teefy, P. J., Graham, J. J., May, M. R. L., Cantor, W. J., Wood, D. A., et al. (2016) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.116.004336 · Cited by 23
Biomaterial property-controlled stem cell fates for cardiac regeneration
Xu, Y., & Guan, J. (2016) · Bioactive Materials · doi:10.1016/j.bioactmat.2016.03.002 · Cited by 21
Titanium Plate Fixation versus Conventional Closure for Sternal Dehiscence after Cardiac Surgery
Jongbloed, L. M., Sonker, U., Kloppenburg, G. T. L., & Vos, R. J. (2016) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0036-1583297 · Cited by 21
Thierfelder, N., König, F., Bombien, R. H., Fano, C., Reichart, B., Wintermantel, E., Schmitz, C., & Akra, B. (2013) · ASAIO Journal · doi:10.1097/mat.0b013e318289b95e · Cited by 20
Kitahara, M., Miyagawa, S., Fukushima, S., Saito, A., Shintani, A., Akita, T., & Sawa, Y. (2017) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/j.semtcvs.2017.01.016 · Cited by 19
Fallahiarezoudar, E., Ahmadipourroudposht, M., Yusof, N. M., Idris, A., & Ngadiman, N. H. A. (2017) · Polymers · doi:10.3390/polym9110584 · Cited by 18
Jakobsen, L., Christiansen, E. H., Mæng, M., Kristensen, S. D., Bøtker, H. E., Terkelsen, C. J., Madsen, M., Raungaard, B., Jensen, S. E., Christensen, M. K., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.04.019 · Cited by 17
van der Heijden, L. C., Kok, M. M., Zocca, P., Jessurun, G. A. J., Schotborgh, C. E., Roguin, A., Benit, E., Aminian, A., Danse, P. W., Löwik, M. M., et al. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.12.011 · Cited by 16
Shawcross, J. T., Bakhai, A., Ansaripour, A., Armstrong, J., Lewis, D., Agg, P., de Godoy, R. F., & Blunn, G. W. (2017) · Open Heart · doi:10.1136/openhrt-2015-000357 · Cited by 15
Coronary stent restenosis and the association with allergy to metal content of 316L stainless steel
Slodownik, D., Danenberg, C., Merkin, D., Swaid, F., Moshe, S., Ingber, A., Lotan, H., & Durst, R. Y. (2018) · Cardiovascular journal of South Africa/Cardiovascular journal of Southern Africa · doi:10.5830/cvja-2017-036 · Cited by 15
Grefen, L., König, F., Grab, M., Hagl, C. M., & Thierfelder, N. (2018) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-018-6186-6 · Cited by 15
Evolution of the SYNERGY Bioresorbable Polymer Metallic Coronary Stent
Shreenivas, S., & Kereiakes, D. J. (2018) · Future Cardiology · doi:10.2217/fca-2018-0040 · Cited by 14
Natural Cardiac Extracellular Matrix Sheet as a Biomaterial for Cardiomyocyte Transplantation
Lee, K., Kim, H., Nemeno, J. G., Yang, W., Yoon, J., Lee, S., & Lee, J. I. (2015) · Transplantation Proceedings · doi:10.1016/j.transproceed.2014.12.030 · Cited by 13
Sakamoto, A., Torii, S., Jinnouchi, H., Virmani, R., & Finn, A. V. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1515012 · Cited by 13
Natural Sources of Extracellular Matrix for Cardiac Repair
Spinali, K. L., & Schmuck, E. G. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-97421-7_6 · Cited by 13
Rasmussen, J. J., Skov, S. N., Nielsen, D. B., Jensen, I. L., Tjørnild, M. J., Johansen, P., & Hjortdal, V. E. (2019) · Journal of Cardiothoracic Surgery · doi:10.1186/s13019-019-0830-1 · Cited by 12
Dai, W., Kay, G. L., & Kloner, R. A. (2014) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/1074248413517746 · Cited by 10
Leskovar, B., Furlan, T., Poznic, S., Hrastelj, M., & Adamlje, A. (2019) · The Journal of Vascular Access · doi:10.1177/1129729819826032 · Cited by 10
Jones, D. A., Rathod, K. S., Gallagher, S., Weerackody, R. P., Knight, C. J., Rothman, M. T., Mathur, A., Jain, A., Timmis, A., & Wragg, A. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24513 · Cited by 8
Polymer microfiber meshes facilitate cardiac differentiation of c-kit+ human cardiac stem cells
Kan, L., Thayer, P., Fan, H., Ledford, B. T., Chen, M., Goldstein, A. S., Cao, G., & He, J. (2016) · Experimental Cell Research · doi:10.1016/j.yexcr.2016.07.024 · Cited by 8
Sekimoto, Y., Obara, H., Matsubara, K., Fujimura, N., Harada, H., & Kitagawa, Y. (2017) · Organogenesis · doi:10.1080/15476278.2017.1280211 · Cited by 8
Karjalainen, P. P., Mikkelsson, J., Paana, T., & Nammas, W. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.26104 · Cited by 6
Orlik, B., Milewski, K. P., Derbisz, K., Jelonek, M., Chrząszcz, P., Beil, S., Młodziankowski, A., Picheta, W., Buszman, P. P., & Buszman, P. E. (2018) · Advances in Interventional Cardiology · doi:10.5114/aic.2018.76406 · Cited by 4
Sun, H., Liu, C., Liu, C., Tang, M., Cao, G., Zhang, Q., & Gu, X. (2018) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/1074248418806060 · Cited by 4
Late Disruption of a Polyethylene Terephthalate Aortic Graft 30 Years after Initial Graft Placement
Matsushita, A., Tsunoda, Y., Hattori, T., & Mihara, W. (2017) · EJVES Short Reports · doi:10.1016/j.ejvssr.2017.11.001 · Cited by 3
Combined total mitral and tricuspid valve reconstruction with the use of CorMatrix in an adult
Szałański, P., Uziębło‐Życzkowska, B., & Zaleska, M. (2018) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivy200 · Cited by 3
Cited by
Biointerface Coatings With Structural and Biochemical Properties Modifications of Biomaterials
Lee, C., Hu, S., Christy, J., Chou, F., Ramli, T. C., & Chen, H. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202202286 · Cited by 59
Extracellular Matrix Coatings on Cardiovascular Materials—A Review
Yao, S., Cui, J., Chen, S., Zhou, X., Li, J., & Zhang, K. (2022) · Coatings · doi:10.3390/coatings12081039 · Cited by 31
In vitro degradation behavior of shape memory PLLA-TMC random copolymers
Hu, X., Mi, S., Lu, J., Cao, J., Xing, L., Lin, Z., Chen, D., Lu, Y. Q., He, J., Xiong, C., et al. (2021) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2021.126220 · Cited by 30
Briassoulis, G., Ilia, S., & Briassouli, E. (2025) · Life · doi:10.3390/life15071057 · Cited by 15
Conductive Polymers for Cardiovascular Applications
Arshad, A., Irfan, H., Iftikhar, S., & Yameen, B. (2022) · Springer eBooks · doi:10.1007/978-981-16-3667-7_12 · Cited by 7
Metadata
- Authors
- Xu, X.-H., Yang, X., Zheng, C.-G., & Cui, Y.
- Affiliations
- Zhejiang Provincial People's Hospital (CN)
- Venue
- Regenerative Medicine
- Publisher
- Informa UK Limited
- Published
- 2020-05
- Volume
- 15
- Issue
- 5
- Pages
- 1637-1645
- ISSN
- 1746-0751 (ISSN-L)
- 1746-076X
- OpenAlex
- W3036211887
- Cited by
- 5
- References
- 58
- Citations by year
- 2025: 1 · 2023: 1 · 2022: 2 · 2021: 1
- FWCI
- 0.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Regenerative Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Zhejiang Provincial Science and Technology Projects (LGF19H020009)
- Zhejiang Provincial Natural Science Foundation of China (LY18H020009)
- ZHangzhou Medical Technology Plan Project (020190129 to X-H Xu)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- cardiovascular biomaterials, hemocompatibility, surface modification, biocompatibility, heart valve replacement, tissue engineering, biomaterial design
- MeSH terms
- Animals, Biocompatible Materials, Cardiovascular Diseases, Humans, Tissue Engineering, Regenerative Medicine, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.