Abstract
Programming materials with tunable physical and chemical interactions among its components pave the way of generating 3D functional active microsystems with various potential applications in tissue engineering, drug delivery, and soft robotics. Here, the development of a recapitulated fascicle‐like implantable muscle construct by programmed self‐folding of poly(ethylene glycol) diacrylate hydrogels is reported. The system comprises two stacked layers, each with differential swelling degrees, stiffnesses, and thicknesses in 2D, which folds into a 3D tube together. Inside the tubes, muscle cell adhesion and their spatial alignment are controlled. Both skeletal and cardiac muscle cells also exhibit high viability, and cardiac myocytes preserve their contractile function over the course of 7 d. Integration of biological cells with smart, shape‐changing materials could give rise to the development of new cellular constructs for hierarchical tissue assembly, drug testing platforms, and biohybrid actuators that can perform sophisticated tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Programmable matter by folding
Hawkes, E., An, B., Benbernou, N. M., Tanaka, H., Kim, S., Demaine, E. D., Rus, D., & Wood, R. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914069107 · Cited by 658
Cited by
Light-Triggered Drug Release from 3D-Printed Magnetic Chitosan Microswimmers
Bozuyuk, U., Yasa, O., Yasa, I. C., Ceylan, H., Kizilel, S., & Sitti, M. (2018) · ACS Nano · doi:10.1021/acsnano.8b05997 · Cited by 422
Self-citationHakim Khalili, M., Zhang, R., Wilson, S., Goel, S., Impey, S. A., & Aria, A. I. (2023) · Polymers · doi:10.3390/polym15102341 · Cited by 114
Trucco, D., Vannozzi, L., Teblum, E., Telkhozhayeva, M., Nessim, G. D., Affatato, S., Al‐Haddad, H., Lisignoli, G., & Ricotti, L. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001434 · Cited by 94
Self-citationRecent Advances in the Design of Cardiovascular Materials for Biomedical Applications
Xu, X.-H., Yang, X., Zheng, C.-G., & Cui, Y. (2020) · Regenerative Medicine · doi:10.2217/rme-2019-0135 · Cited by 5
Metadata
- Authors
- Vannozzi, L., Yasa, I. C., Ceylan, H., Menciassi, A., Ricotti, L., & Sitti, M.
- Venue
- Macromolecular Bioscience
- Publisher
- Wiley
- Published
- 2018-03-14
- Volume
- 18
- Issue
- 4
- Pages
- e1700377-e1700377
- ISSN
- 1616-5187 (ISSN-L)
- 1616-5195
- OpenAlex
- W2789719441
- Cited by
- 71
- References
- 1
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self‐Folded Hydrogel Tubes for Implantable Muscular Tissue Scaffolds. https://app.cochat.ai/papers/10.1002/mabi.201700377
- The paper
- Vannozzi, L., Yasa, I. C., Ceylan, H., Menciassi, A., Ricotti, L., & Sitti, M. (2018). Self‐Folded Hydrogel Tubes for Implantable Muscular Tissue Scaffolds. Macromolecular Bioscience. https://doi.org/10.1002/mabi.201700377
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.