Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Control of pore size and structure of tissue engineering scaffolds produced by supercritical fluid processing

Open access
School of Chemistry, The University of Nottingham, University Park, Nottingham, NG7 2RD, Tai, H, Mather, ML, Howard, D, Wang, W, White, LJ, Crowe, JA, Morgan, SP, Chandra, A, Williams, DJ, Howdle, SM, Shakesheff, KM·2007·European Cells and Materials

Abstract

Tissue engineering scaffolds require a controlled pore size and structure to host tissue formation. Supercritical carbon dioxide (scCO2) processing may be used to form foamed scaffolds in which the escape of CO2 from a plasticized polymer melt generates gas bubbles that shape the developing pores. The process of forming these scaffolds involves a simultaneous change in phase in the CO2 and the polymer, resulting in rapid expansion of a surface area and changes in polymer rheological properties. Hence, the process is difficult to control with respect to the desired final pore size and structure. In this paper, we describe a detailed study of the effect of polymer chemical composition, molecular weight and processing parameters on final scaffold characteristics. The study focuses on poly(DL-lactic acid) (PDLLA) and poly(DL-lactic acid-co-glycolic acid) (PLGA) as polymer classes with potential application as controlled release scaffolds for growth factor delivery. Processing parameters under investigation were temperature (from 5 to 55 degrees C) and pressure (from 60 to 230 bar). A series of amorphous PDLLA and PLGA polymers with various molecular weights (from 13 KD to 96 KD) and/or chemical compositions (the mole percentage of glycolic acid in the polymers was 0, 15, 25, 35 and 50 respectively) were employed. The resulting scaffolds were characterised by optical microscopy, scanning electron microscopy (SEM), and micro X-ray computed tomography (microCT). This is the first detailed study on using these series polymers for scaffold formation by supercritical technique. This study has demonstrated that the pore size and structure of the supercritical PDLLA and PLGA scaffolds can be tailored by careful control of processing conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.22203/ecm.v014a07

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 232

Metadata

Authors
School of Chemistry, T. U. O. N., Tai, H., Mather, M., Howard, D., Wang, W., White, L., Crowe, J., Morgan, S., Chandra, A., Williams, D., Howdle, S., & Shakesheff, K.
Venue
European Cells and Materials
Published
2007-12-17
Volume
14
Pages
64-77
ISSN
1473-2262 (ISSN-L)
OpenAlex
W2118948459
Cited by
232
References
1
FWCI
9.63
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of pore size and structure of tissue engineering scaffolds produced by supercritical fluid processing. https://app.cochat.ai/papers/10.22203/ecm.v014a07
The paper
School of Chemistry, T. U. O. N., Tai, H., Mather, M., Howard, D., Wang, W., White, L., Crowe, J., Morgan, S., Chandra, A., Williams, D., Howdle, S., & Shakesheff, K. (2007). Control of pore size and structure of tissue engineering scaffolds produced by supercritical fluid processing. European Cells and Materials. https://doi.org/10.22203/ecm.v014a07

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.