The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Convolutional Recurrent Neural Networks for Electrocardiogram Classification
Open accessAbstract
We propose two deep neural network architectures for classification of arbitrary-length electrocardiogram (ECG) recordings and evaluate them on the atrial fibrillation (AF) classification data set provided by the Phy-sioNet/CinC Challenge 2017.The first architecture is a deep convolutional neural network (CNN) with averagingbased feature aggregation across time.The second architecture combines convolutional layers for feature extraction with long-short term memory (LSTM) layers for temporal aggregation of features.As a key ingredient of our training procedure we introduce a simple data augmentation scheme for ECG data and demonstrate its effectiveness in the AF classification task at hand.The second architecture was found to outperform the first one, obtaining an F 1 score of 82.1% on the hidden challenge testing set.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SMOTE synthetic minority over-sampling technique
Chawla, N. V., Bowyer, K. W., Hall, L. O., & Kegelmeyer, W. P. (2002) · Journal of Artificial Intelligence Research · doi:10.1613/jair.953 · Cited by 32,865
Learning to Diagnose with LSTM Recurrent Neural Networks
Lipton, Z. C., Kale, D. C., Elkan, C., & Wetzel, R. (2015) · arXiv · doi:10.48550/arxiv.1511.03677 · Cited by 879
Cited by
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
1D convolutional neural networks and applications: A survey
Kiranyaz, S., Avci, O., Abdeljaber, O., Ince, T., Gabbouj, M., & Inman, D. J. (2021) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.107398 · Cited by 2,835
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
A review on deep learning methods for ECG arrhythmia classification
Ebrahimi, Z., Loni, M., Daneshtalab, M., & Gharehbaghi, A. (2020) · Expert Systems with Applications: X · doi:10.1016/j.eswax.2020.100033 · Cited by 447
1-D Convolutional Neural Networks for Signal Processing Applications
Kiranyaz, S., Ince, T., Abdeljaber, O., Avci, O., & Gabbouj, M. (2019) · ICASSP 2019 - 2019 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2019.8682194 · Cited by 402
Metadata
- Authors
- Zihlmann, M., Perekrestenko, D., & Tschannen, M.
- Venue
- Computing in Cardiology Conference (CinC)
- Publisher
- Computing in Cardiology
- Published
- 2017-09-14
- Volume
- 44
- ISSN
- 2325-887X (ISSN-L)
- OpenAlex
- W2765264620
- Cited by
- 246
- References
- 2
- FWCI
- 50.95
- Type
- conference paper
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Convolutional Recurrent Neural Networks for Electrocardiogram Classification. https://app.cochat.ai/papers/10.22489/cinc.2017.070-060
- The paper
- Zihlmann, M., Perekrestenko, D., & Tschannen, M. (2017). Convolutional Recurrent Neural Networks for Electrocardiogram Classification. Computing in Cardiology Conference (CinC). https://doi.org/10.22489/cinc.2017.070-060
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.