Cited by 30Tactile and Sensory InteractionsNeuroscience and Neural EngineeringMuscle activation and electromyography studies

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Electrical stimulation of the forearm: A method for transmitting sensory signals from the artificial hand to the brain

Perovic, Minja, Stevanovic, Marija, Jevtic, Tijana, Strbac, Matija, Bijelic, Goran, Vucetic, Cedomir, Popovic-Maneski, Lana, Popovic, Dejan·2013·Journal of Automatic Control

Abstract

This research is in line with an important comment from the first amputee who tried the prosthetic hand with tactile feedback developed within the Smarthand project [1]. While trying the system with tactile feedback the patient said: "It's a feeling I have not had in a long time. When I grab something tightly I can feel it in the fingertips. It's strange since I don't have them anymore! It's amazing." We describe here the instrumentation and methods for testing the abilities of humans to discriminate sensations generated by electrical stimulation applied to the skin on the forearm. The instruments allowed testing of electrical stimulation with various properties (pulse duration, intensity, and rate). We tested the perception and pain thresholds, with the emphasis that comfortable sensations are a must. During the tests subjects were asked to locate the point on the skin that was stimulated and describe their perception of the elicited sensation. Results of first tests with small concentric electrodes suggest that non-amputees can distinguish up to seven perceptual qualities (the most common one was vibration, followed by tingling and tickling). Certain sensations had a higher occurrence rate along one axial line of the forearm than another of the forearm. In terms of spatial acuity, the subjects had more difficulties in distinguishing between the positions in the axial direction of the forearm compared with the circumferential direction. These results guided the design of the new array electrode with multiple cathodes and anodes positioned circumferential to the forearm. The results of the tests conducted with this electrode design showed high location discernment accuracy, and demonstrated the ability to memorize and later accurately recall six different electrical ?messages? created by delivering electrical stimulation onto three different electrode pads with two different stimulation parameters.

Overview

Integrity signals

Registry

Crossref · 10.2298/jac1301013p

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Cited by

Sorted by citations

See all 30

Metadata

Authors
Perovic, M., Stevanovic, M., Jevtic, T., Strbac, M., Bijelic, G., Vucetic, C., Popovic-Maneski, L., & Popovic, D.
Affiliations
  • Faculty of Electrical Engineering, Belgrade
  • University of Belgrade (RS)
  • Faculty of Electrical Engineering, Belgrade + Tecnalia Serbia Ltd, Belgrade
  • Tecnalia Serbia Ltd, Belgrade
  • Medical School, Belgrade + Clinical Center of Serbia, Belgrade
  • State University of Novi Pazar, Novi Pazar + Institute of Technical Sciences of SANU, Belgrade
Venue
Journal of Automatic Control
Published
2013
Volume
21
Issue
1
Pages
13-18
ISSN
  • 1450-9903 (ISSN-L)
  • 2406-0984
OpenAlex
W2119426064
Cited by
28
References
14
Citations by year
2025: 1 · 2024: 2 · 2023: 2 · 2022: 4 · 2021: 2 · 2020: 1 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 4 · 2015: 3 · 2014: 2
FWCI
1.64
Type
journal article
Language
en
Open access
closed
Locations
Journal of Automatic Control (publishedVersion)
Funders
Ministry of Education, Science and Technological Development of the Republic of Serbia (TR35040)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
electrical stimulation, forearm, sensory feedback, prosthetic hand, tactile feedback, amputation, perception threshold, pain threshold, spatial acuity, electrode array design, concentric electrodes, stimulation parameters

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review