CoChat

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Object Discrimination With an Artificial Hand Using Electrical Stimulation of Peripheral Tactile and Proprioceptive Pathways With Intrafascicular Electrodes

Horch, Kenneth, Meek, Sanford, Taylor, Tyson G., Hutchinson, Douglas T. · 2011 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

Trans-radial amputee subjects were implanted with intrafascicular electrodes in the stumps of the median and ulnar nerves. Electrical stimulation through these electrodes was used to provide sensations of touch and finger position referred to the amputated hand. Two subjects were asked to identify different objects as to size and stiffness by manipulating them with a myo-electric hand without visual or auditory cues. Both subjects were provided with information about contact force with the objects via tactile sensations referred to their phantom hands. One subject, who was provided with information about finger position in the prosthetic hand via a different tactile sensation referred to his phantom hand, was unable to correctly identify the objects. The other subject, who received information about finger position via a proprioceptive sensation referred to his phantom hand, correctly identified the objects at a level statistically significantly above chance performance.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2011.2162635

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 48 references

Research works printed but not linked: 3

  1. sueda, 1972, Evaluation of sensation apparatus for hand prosthesis and controllability of hand proshtesis, Biomechanisms, 171
  2. sueda, 1969, Sensory device for the artificial arm, 8th ACEMB
  3. 1991, An American Initiative: Workshop on upper extremity prosthetics, The Limbs of Love Foundation

Cited by

See all 194

Metadata

Authors
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T.
Affiliations
University of Utah (US)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2011-10
Volume
19
Issue
5
Pages
483-489
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2097700774
Cited by
194
References
48
Citations by year
2026: 2 · 2025: 6 · 2024: 12 · 2023: 11 · 2022: 15 · 2021: 24 · 2020: 14 · 2019: 18 · 2018: 17 · 2017: 11 · 2016: 12 · 2015: 10 · 2014: 13 · 2013: 14 · 2012: 11
FWCI
5.56
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
object discrimination, artificial hand, transradial amputation, intrafascicular electrodes, peripheral nerve stimulation, tactile feedback, proprioception, myoelectric hand, phantom hand, median nerve, ulnar nerve, contact force feedback
MeSH terms
Adult, Amputation, Surgical, Amputees, Artificial Limbs, Discrimination, Psychological, Electric Stimulation, Electrodes, Implanted, Electromyography, Feedback, Fingers, Hand, Humans, Male, Median Nerve, Neural Pathways, Peripheral Nerves, Phantom Limb, Proprioception, Touch, Ulnar Nerve

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Object Discrimination With an Artificial Hand Using Electrical Stimulation of Peripheral Tactile and Proprioceptive Pathways With Intrafascicular Electrodes. https://app.cochat.ai/papers/10.1109/tnsre.2011.2162635
The paper
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011). Object Discrimination With an Artificial Hand Using Electrical Stimulation of Peripheral Tactile and Proprioceptive Pathways With Intrafascicular Electrodes. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2011.2162635

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.