The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Self-Starting Cusum Charts for Location and Scale
Abstract
In some quality control problems, it is not known what the exact process mean and standard deviation are under control but it is desired to determine whether there have been drifts from the conditions obtained at the process start-up. This situation is not well-covered by standard cumulative sum procedures, which generally assume known process parameters. This paper uses the running mean and standard deviation of all observations made on the process since start-up as substitutes for the unknown true values of the process mean and standard deviation. Using some theoretical properties of independence of residuals, two pairs of cusums are set up: one testing for constancy of location of the process, and the other for constancy of the spread. While the process is under control, both these cusum pairs are of approximately normal N(O, 1) quantities (and therefore are well understood), but if the location, the spread or both change, then non-centrality is introduced into one or both of the location and scale cusum pairs, and it drifts out-of-control. It is shown that the procedure performs well in detecting changes in the process, even in comparison with the often utopian situation in which the process mean and variance are known exactly prior to the start of the cusum. precisely if large numbers of spurious signals are to be avoided. While it has usually been assumed in discussion of cusums that the process specification is known exactly, there are many circumstances in which it is to some extent uncertain, and under these conditions the assumption of known mean and variance is inappropriate. A case of particular interest to the author arises in the control of assaying in a chemical laboratory for bias and precision. A good way of doing this is (Mandel 1964) by using reference materials. A reference material is a batch of the same sort of material as is assayed in the laboratory (obtained for example from a previous consignment), portions of which are assayed regularly along with the production material. A depar- ture of the assays of the reference material from their previous mean or standard deviation indicates a change in bias or precision. Note that the control required is simply for any change in the values obtained for the reference material. It is immaterial what the true assay of the reference material (the ideal target process mean) actually is, and the quality control system should not be predicated on the assumption of an exact knowledge of the process mean. This indeterminancy presents
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hawkins, D. M. (1980) · doi:10.1007/978-94-015-3994-4 · Cited by 2,982
Self-citationCombined Shewhart-Cusum control chart for improved quality control in clinical chemistry
Westgard, J. O., Groth, T., Aronsson, T., & de Verdier, C. H. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.10.1881 · Cited by 138
Cited by
Zile, M. R., Bennett, T. D., St. John Sutton, M., Cho, Y. K., Adamson, P. B., Aaron, M. F., Aranda, J. M., Abraham, W. T., Smart, F. W., Stevenson, L. W., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.783910 · Cited by 571
The Changepoint Model for Statistical Process Control
Hawkins, D. M., Qiu, P., & Kang, C. W. (2003) · Journal of Quality Technology · doi:10.1080/00224065.2003.11980233 · Cited by 382
Self-citationA layer-by-layer quality monitoring framework for 3D printing
Najjartabar Bisheh, M., Chang, S. I., & Lei, S. (2021) · Computers & Industrial Engineering · doi:10.1016/j.cie.2021.107314 · Cited by 58
Metadata
- Authors
- Hawkins, D. M.
- Venue
- The Statistician
- Publisher
- JSTOR
- Published
- 1987
- Volume
- 36
- Issue
- 4
- Pages
- 299
- ISSN
- 0039-0526 (ISSN-L)
- OpenAlex
- W2554979051
- Cited by
- 210
- References
- 2
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.