Depth-Dose Equivalent Relationship for Cosmic Rays at Various Solar Minima
The DOI matches its Crossref record.
Abstract
Galactic cosmic rays (GCR) pose a serious radiation hazard for long-duration missions. In designing a lunar habitat or a Mars transfer vehicle, the radiation exposure determines the shielding thickness, and hence the weight of spacecraft. In designing a habitat one has to focus on the worst-case radiation flux and its uncertainties. Using the spherically symmetric diffusion theory of the solar modulation of GCR, and data on the differential energy spectra of hydrogen, helium, oxygen, and iron from 1965 to 1989, it has been shown that the flux is determined by the diffusion parameter which is a function of the time in the solar cycle. This analysis also showed that the fluxes in the 1954 and 1976-1977 solar minima were similar and higher than those in 1965. In this paper, we have extended the spherical solar modulation theory back to 1954. These results show that the 1954-1955 GCR flux was nearly the same as that from 1976 to 1977 and that the 1965 flux values were nearly the same as those in 1986. Using this theory we have obtained the GCR spectra for all the nuclei and calculated the depth dose as a function of aluminum thickness. Using the ICRP 26 value for the quality factor, and the 1976-1977 spectra, it is shown that the shielding required to stay below 0.5 Sv is 17.5(-3)+8 g cm-2 of aluminum, and 9(-1.5)+5 g cm-2 to stay below 0.6 Sv. The calculated dose equivalent using the ICRP 60 values for quality factors is about 15% higher than that calculated using the ICRP 26 value. However, the errors on the quality factor itself may be substantial and are not taken into account.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528
Self-citationCucinotta, F. A., Nikjoo, H., & Goodhead, D. T. (1998) · Radiation Research · doi:10.2307/3579651 · Cited by 134
Self-citationAn analysis of interplanetary space radiation exposure for various solar cycles
Badhwar, G. D., Cucinotta, F. A., & O'Neill, P. M. (1994) · Radiation Research · doi:10.2307/3578590 · Cited by 69
Self-citationLong-term modulation of galactic cosmic radiation and its model for space exploration
Badhwar, G. D., & O'Neill, P. M. (1994) · Advances in Space Research · doi:10.1016/0273-1177(94)90537-1 · Cited by 62
Self-citationEffective Dose Equivalent on the Ninth Shuttle–Mir Mission (STS-91)
Yasuda, H., Badhwar, G. D., Komiyama, T., & Fujitaka, K. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0705:edeotn]2.0.co;2 · Cited by 56
Self-citationEffective Dose Measured with a Life Size Human Phantom in a Low Earth Orbit Mission
YASUDA, H. (2009) · Journal of Radiation Research · doi:10.1269/jrr.08105 · Cited by 26
(1998) · National Aeronautics and Space Administration Report · Cited by 19
Metadata
- Authors
- Badhwar, G. D., Cucinotta, F. A., & O'Neill, P. M.
- Venue
- Radiation Research
- Publisher
- JSTOR
- Published
- 1993-04
- Volume
- 134
- Issue
- 1
- Pages
- 9
- ISSN
- 0033-7587 (ISSN-L)
- OpenAlex
- W1978572198
- Cited by
- 21
- References
- 0
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.