Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 224

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Automated Identification of Cephalometric Landmarks: Part 2- Might It Be Better Than human?

Open access
Hwang, Hye-Won, Park, Ji-Hoon, Moon, Jun-Ho, Yu, Youngsung, Kim, Hansuk, Her, Soo-Bok, Srinivasan, Girish, Aljanabi, Mohammed Noori A., Donatelli, Richard E., Lee, Shin-Jae · 2020 · The Angle Orthodontist

Abstract

Objectives: To compare detection patterns of 80 cephalometric landmarks identified by an automated identification system (AI) based on a recently proposed deep-learning method, the You-Only-Look-Once version 3 (YOLOv3), with those identified by human examiners. Materials and Methods: The YOLOv3 algorithm was implemented with custom modifications and trained on 1028 cephalograms. A total of 80 landmarks comprising two vertical reference points and 46 hard tissue and 32 soft tissue landmarks were identified. On the 283 test images, the same 80 landmarks were identified by AI and human examiners twice. Statistical analyses were conducted to detect whether any significant differences between AI and human examiners existed. Influence of image factors on those differences was also investigated. Results: Upon repeated trials, AI always detected identical positions on each landmark, while the human intraexaminer variability of repeated manual detections demonstrated a detection error of 0.97 ± 1.03 mm. The mean detection error between AI and human was 1.46 ± 2.97 mm. The mean difference between human examiners was 1.50 ± 1.48 mm. In general, comparisons in the detection errors between AI and human examiners were less than 0.9 mm, which did not seem to be clinically significant. Conclusions: AI showed as accurate an identification of cephalometric landmarks as did human examiners. AI might be a viable option for repeatedly identifying multiple cephalometric landmarks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2319/022019-129.1

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 224

Metadata

Authors
Hwang, H.-W., Park, J.-H., Moon, J.-H., Yu, Y., Kim, H., Her, S.-B., Srinivasan, G., Aljanabi, M. N. A., Donatelli, R. E., & Lee, S.-J.
Venue
The Angle Orthodontist
Published
2019-07-22
Volume
90
Issue
1
Pages
69-76
ISSN
0003-3219 (ISSN-L)
OpenAlex
W2963943687
Cited by
224
References
2
FWCI
17.64
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated Identification of Cephalometric Landmarks: Part 2- Might It Be Better Than human? https://app.cochat.ai/papers/10.2319/022019-129.1
The paper
Hwang, H.-W., Park, J.-H., Moon, J.-H., Yu, Y., Kim, H., Her, S.-B., Srinivasan, G., Aljanabi, M. N. A., Donatelli, R. E., & Lee, S.-J. (2020). Automated Identification of Cephalometric Landmarks: Part 2- Might It Be Better Than human? The Angle Orthodontist. https://doi.org/10.2319/022019-129.1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.