Biologically and Mechanically Biocompatible Titanium Alloys
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Nb, Ta, and Zr are the favorable nontoxic and allergy-free alloying elements suitable for use in titanium alloys for biomedical applications. Low-rigidity titanium alloys composed of nontoxic and allergy-free elements are receiving considerable attention. The advantage of low-rigidity titanium alloys in the healing of bone fracture and bone remodeling is successfully proven by using tibia of rabbit as a fracture model. Ni-free superelastic and shape memory titanium alloys for biomedical applications are being actively developed. The mechanical properties such as fatigue and fretting fatigue are important from the viewpoint of mechanical properties, which may be collectively referred to as mechanical biocompatibilities in the broad sense, in addition to the rigidity, i.e. Young’s modulus. Bioactive surface modifications of titanium alloys for biomedical applications are very important for achieving further biocompatibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent metallic materials for biomedical applications
Niinomi, M. (2002) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-002-0109-2 · Cited by 1,508
Self-citationDesign and mechanical properties of new β type titanium alloys for implant materials
Kuroda, D., Niinomi, M., Morinaga, M., Kato, Y., & Yashiro, T. (1998) · Materials Science and Engineering A · doi:10.1016/s0921-5093(97)00808-3 · Cited by 1,323
Self-citationMultifunctional Alloys Obtained via a Dislocation-Free Plastic Deformation Mechanism
Saito, T., Furuta, T., Hwang, J.-H., Kuramoto, S., Nishino, K., Suzuki, N., Chen, R., Yamada, A., Ito, K., Seno, Y., et al. (2003) · Science · doi:10.1126/science.1081957 · Cited by 935
Mechanical properties of porous titanium compacts prepared by powder sintering
Oh, I.-H., Nomura, N., Masahashi, N., & Hanada, S. (2003) · Scripta Materialia · doi:10.1016/j.scriptamat.2003.08.018 · Cited by 569
Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti–29Nb–13Ta–4.6Zr
Niinomi, M. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00069-3 · Cited by 549
Self-citationCytocompatibility of various metal and development of new titanium alloys for medical implants
Okazaki, Y., Rao, S., Tateishi, T., & Ito, Y. (1998) · Materials Science and Engineering: A · doi:10.1016/s0921-5093(97)00809-5 · Cited by 173
Cited by
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
Ibrahim, M. Z., Sarhan, A. A. D., Yusuf, F., & Hamdi, M. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.04.231 · Cited by 344
Nanostructured titanium-based materials for medical implants: Modeling and development
Mishnaevsky, L., Levashov, E., Valiev, R. Z., Segurado, J., Sabirov, I., Enikeev, N., Prokoshkin, S., Solov’yov, A. V., Korotitskiy, A., Gutmanas, E., et al. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.04.002 · Cited by 268
Understanding biomaterial-tissue interface quality: combined in vitro evaluation
Gasik, M. (2017) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2017.1348872 · Cited by 55
Metadata
- Authors
- Niinomi, M.
- Venue
- MATERIALS TRANSACTIONS
- Publisher
- Japan Institute of Metals
- Published
- 2008
- Volume
- 49
- Issue
- 10
- Pages
- 2170-2178
- ISSN
- 1345-9678 (ISSN-L)
- 1347-5320
- OpenAlex
- W2079291535
- Cited by
- 205
- References
- 6
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.