Evaluating surface roughness of a polyamide denture base material in comparison with poly (methyl methacrylate)
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Polyamide denture base materials are more flexible than the commonly used poly (methyl methacrylate) (PMMA). However polishability of polyamides has not been examined adequately. This study investigated the surface roughness (Ra) and clinical acceptability of samples of a polyamide denture base material and PMMA fabricated by injection moulding and traditional heat processing systems, respectively. Half of each sample surface was polished using the conventional technique (lathe with pumice followed by high shine buffs) and the other half was left unpolished. A profilometer was used to measure Ra along 3 tracks on each surface before and after polishing. Two-way ANOVA was used to compare the two surfaces of the two materials for variations in Ra values. Polyamide denture base material when polished with conventional laboratory technique became more than 7 times smoother whereas processed PMMA when polished became more than 20 times smoother using the same polishing technique. However the surface roughness of polyamide is well within the accepted norm of 0.2 µm Ra. Polyamide produces a clinically acceptable smoothness after conventional polishing by lathe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
The influence of abutment surface roughness on plaque accumulation and peri‐implant mucositis
Bollen, C. M. L., Papaioanno, W., Van Eldere, J., Schepers, E., Quirynen, M., & Van Steenberghe, D. (1996) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1996.070302.x · Cited by 661 · cited 2×
“2 μm where no further reduction in plaque accumulation is expected under that level (21,23,27).”
BackgroundQuirynen, M., Bollen, C. M. L., Papaioannou, W., Eldere, J. V., & van Steenberghe, D. (1996) · PubMed · Cited by 523
Quirynen, M., Marechal, M., Busscher, H. J., Weerkamp, A. H., Darius, P. L., & van Steenberghe, D. (1990) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1990.tb01077.x · Cited by 504 · cited 2×
“2 μm where no further reduction in plaque accumulation is expected under that level (21,23,27).”
BackgroundAdherence of Candida albicans to denture-base materials with different surface finishes
Radford, D. R., Sweet, S. P., Challacombe, S. J., & Walter, J. D. (1998) · Journal of Dentistry · doi:10.1016/s0300-5712(97)00034-1 · Cited by 337
Reassessing the presence of Candida albicans in denture-related stomatitis
Barbeau, J., Séguin, J., Goulet, J. P., de Koninck, L., Avon, S. L., Lalonde, B., Rompré, P., & Deslauriers, N. (2003) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1067/moe.2003.44 · Cited by 288
Toxicity of methyl methacrylate in dentistry
Leggat, P. A., & Kedjarune, U. (2003) · International Dental Journal · doi:10.1111/j.1875-595x.2003.tb00736.x · Cited by 186 · cited 1×
“Hypersensitivity to PMMA and allergic reactions to residual monomer have been reported (1-6).”
BackgroundEffects of polishing techniques on the surface roughness of acrylic denture base resins
Kuhar, M., & Funduk, N. (2005) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2004.10.002 · Cited by 160 · cited 1×
“The conventional polishing technique and contact profilometers to obtain the Ra values have been used by other investigators and the results of the present study are approximately comparable and lie within the range reported (25,28).”
ResultSurface Roughness of Denture Base Acrylic Resins After Processing and After Polishing
Berger, J. C., Driscoll, C. F., Romberg, E., et al. (2006) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2006.00098.x · Cited by 153 · cited 1×
“(26) have also compared several polishing techniques and concluded that the conventional polishing technique provides a better PMMA surface even though the Ra value in this study is much higher than the”
BackgroundLai, C.-P. (2003) · Dental Materials · doi:10.1016/s0109-5641(03)00084-8 · Cited by 122 · cited 1×
“fractures of acrylic based dentures (7,8).”
In vitro Adherence of Microorganisms to Denture Base Resin with Different Surface Texture
Yamauchi, M., YAMAMOTO, K., Wakabayashi, M., et al. (1990) · Dental Materials Journal · doi:10.4012/dmj.9.19 · Cited by 115 · cited 1×
“The surface properties of any denture base material is of particular concern as studies of denture base materials have shown a direct link between surface roughness, the accumulation of plaque and the adherence of Candida albicans (18,19).”
BackgroundVilaplana, J., Romaguera, C., & Cornellana, F. (1994) · Contact Dermatitis · doi:10.1111/j.1600-0536.1994.tb00568.x · Cited by 115 · cited 1×
“Hypersensitivity to PMMA and allergic reactions to residual monomer have been reported (1-6).”
BackgroundEffect of Polishing Technique and Brushing on Surface Roughness of Acrylic Resins
Oliveira, L. V., Mesquita, M. F., Henriques, G. E. P., Consani, R. L. X., & Fragoso, W. S. (2007) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2007.00274.x · Cited by 46
Metadata
- Authors
- Abuzar, M. A., Bellur, S., Duong, N., Kim, B. B., Lu, P., Palfreyman, N., Surendran, D., & Tran, V. T.
- Venue
- Journal of Oral Science
- Publisher
- Nihon University School of Dentistry
- Published
- 2010
- Volume
- 52
- Issue
- 4
- Pages
- 577-581
- ISSN
- 1343-4934 (ISSN-L)
- 1880-4926
- OpenAlex
- W2123253160
- Cited by
- 174
- References
- 13
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.