Cited by 1Diabetes Management and ResearchDiabetes Management and EducationDiabetes Treatment and Management

852-P: Is Real-Time CGM Superior to Flash Glucose Monitoring? Results of the Type 1 Diabetes CORRIDA Randomized Control Trial

SOUPAL, JAN, HÁSKOVÁ, ANETA, GRUNBERGER, GEORGE, PETRUZELKOVA, LENKA, PARKIN, CHRISTOPHER, SKRHA, JAN, RADOVNICKÁ, LUCIE, HOROVA, EVA +1 more·2020·Diabetes

Abstract

Background: The trial aim was to compare the efficacy of real-time and intermittently-scanned continuous glucose monitoring (rtCGM and isCGM, respectively) in maintaining optimal glycemic control. Methods: In this randomized study, adults with T1D and normal hypoglycemia awareness (GOLD score <4) used rtCGM (Guardian Connect Mobile) or isCGM (Freestyle Libre) during 4 days of physical activity (sport period) and in the subsequent 4 weeks (home period). Main endpoints were time in hypoglycemia (<3.9 mmol/l [<70 mg/dl]) and time in range (3.9-10.0 mmol/l [70-180 mg/dl]). To check for bias between the different sensors used by the rtCGM and isCGM systems, the isCGM group wore an additional blinded Enlite sensor (iPro2) for 6 days. Results: Sixty adults with T1D (age 38±13 years, HbA1c 7.8±1.1% [62±12 mmol/mol]) were randomized to rtCGM (n=30) or isCGM (n=30). All participants completed the study. Time in hypoglycemia (<3.9 mmol/l) was lower among rtCGM participants in the sport period (6.8±5.5% vs. 11.4±8.6%, respectively; p=0.018) and the home period (5.3±2.5% vs. 7.3±4.4%, respectively; p=0.035). Hypoglycemia differences were significant and most notable during the night. rtCGM participants spent more time in range than isCGM participants throughout both the sport (78.5±10.2% vs. 69.7±16%, respectively; p=0.0149) and home (75.6±9.7% vs. 67.4±17.8%, respectively; p=0.0339) periods. The results were robust to the insignificant bias between rtCGM and isCGM sensors that blinded CG…

Integrity signals

Registry

Crossref · 10.2337/db20-852-p

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Guardian Connect System is an AI system based on CGM, has an accompanying smartphone application, and was certified by the FDA in 2018.

    “The Guardian Connect System (manufactured by Medtronic) is an example of an AI system with this functionality. This system is based on CGM, has an accompanying smartphone application,144 and was certified by the FDA in 2018.”

Cited by

Sorted by citations

Authors
SOUPAL, J., HÁSKOVÁ, A., GRUNBERGER, G., PETRUZELKOVA, L., PARKIN, C., SKRHA, J., RADOVNICKÁ, L., HOROVA, E., & PRAZNY, M.
Affiliations
Prague, Czech Republic, Bloomfield Hills, MI, Boulder City, NV, Ústí nad Labem, Czech Republic, Praha, Czech Republic
Venue
Diabetes
Published
2020-06-01
Volume
69
Issue
Supplement_1
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W3034238749
Cited by
0
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
Diabetes (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, real-time continuous glucose monitoring, flash glucose monitoring, hypoglycemia prevention, time in range, glycemic control, physical activity, sensor bias, adults with type 1 diabetes, HbA1c, hypoglycemia awareness

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review