261-OR: Autonomous Artificial Intelligence (AI) Testing for Diabetic Eye Disease (DED) Closes Care Gap and Improves Health Equity on a Systems Level

ALVIN LIU, T.Y., HUANG, JANE, LEHMANN, HAROLD, WOLF, RISA M., CHANNA, ROOMASA, ABRÀMOFF, MICHAEL D.·2023·Diabetes

Abstract

We aimed to examine the change in adherence to annual diabetic eye disease (DED) testing in an integrated healthcare system (Johns Hopkins Community Physicians 30+ community based primary care clinics) before and after deployment of autonomous artificial intelligence (AI). Adherence to annual DED testing is defined as completed evaluation by either a human ophthalmology provider, or autonomous AI within a given calendar year. During the COVID pandemic, autonomous AI (IDx-DR, Digital Diagnostics, Coralville, IA) was deployed at multiple clinics, so that by 2021, some clinics had autonomous AI (AI sites), while others did not (non-AI sites). Overall adherence in 2019 (pre-AI) and 2021 (with AI) were compared, and stratified by demographics, using chi-square or Fisher’s exact test. Changes from 2019 to 2021 in odds of adherence within each subgroup were assessed for significant differences by site type (AI vs. non-AI), using logistic regression with a site type-by-time interaction term. From 2019 to 2021, the overall adherence rate increased from 42.6% to 55.5% at AI sites (1949 patients), and increased from 38.0% to 41.0% at non-AI sites (5379 patients). The increase in overall adherence rate at AI sites was significantly greater than that at non-AI sites (p<0.001). Various patient subgroups (M, F, ≥65 yo, <65 yo, Black, White, Medicare/military/commercial insurance) at AI sites demonstrated a significantly greater (p<0.05) compliance rate increase when compared to the same sub…

Integrity signals

Registry

Crossref · 10.2337/db23-261-or

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

Cited by 3

Authors
ALVIN LIU, T. Y., HUANG, J., LEHMANN, H., WOLF, R. M., CHANNA, R., & ABRÀMOFF, M. D.
Affiliations
Baltimore, MD, Madison, WI, Iowa City, IA
Venue
Diabetes
Published
2023-06-20
Volume
72
Issue
Supplement_1
ISSN
0012-1797 (ISSN-L)
OpenAlex
W4381377927
Cited by
3
References
0
Citations by year
2025: 1 · 2024: 1 · 2023: 1
FWCI
0.50
Type
journal article
Language
en
Open access
closed
Locations
Diabetes (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
Keywords
diabetic eye disease, diabetic retinopathy screening, AI autonomy, health equity, racial disparities, Black patients, primary health centers, COVID-19 pandemic, integrated health system, health inequalities reduction, telemedicine screening, community-based primary care, age and sex differences

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review