OBJECTIVE—To evaluate the impact of masked hypertension in normotensive type 2 diabetic patients on microvascular complications and echocardiographic parameters. RESEARCH DESIGN AND METHODS—A cross-sectional study was conducted in 135 normotensive patients with type 2 diabetes. Patients underwent urinary albumin excretion rate (UAER) measurement, echocardiography, and 24-h ambulatory blood pressure monitoring (ABPM). Patients with increased daytime blood pressure levels (≥135/85 mmHg) were classified as having masked hypertension. RESULTS—The prevalence of masked hypertension was 30% (n = 41). Normotensive and masked hypertensive subjects, based on ambulatory blood pressure, were not different in terms of age, diabetes duration, smoking status, BMI, waist circumference, serum creatinine, glycemic, or lipid profiles. The office systolic blood pressure was higher in those with masked hypertension (127.8 ± 7.5 vs. 122.9 ± 10.2 mmHg, P = 0.003) than in the normotensive group. UAER also was increased in the group with masked hypertension (21.3 μg/min [range 2.5–1,223.5] vs. 8.1 μg/min [1.0–1,143.0], P = 0.001), as was the interventricular septum (1.01 ± 0.15 vs. 0.94 ± 0.13 cm, P = 0.015) and posterior wall (0.96 ± 0.12 vs. 0.90 ± 0.10 cm, P = 0.006) thickness. After adjustments for diabetes duration, sex, smoking, LDL cholesterol, and A1C values, all associations were sustained for daytime systolic blood pressure but not for office systolic blood pressure. CONCLUSIONS—Type 2 diabetic patients with masked hypertension have higher UAER as well as enlargement of ventricular walls compared with the normotensive patients, according to ABPM. Therefore, ABPM is important to identify this high-risk group so as to be able to take interventionist measures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc06-2131

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 108

Metadata

Authors
Leitão, C. B., Canani, L. H., Kramer, C. K., Boza, J. C., Pinotti, A. F., & Gross, J. L.
Venue
Diabetes Care
Published
2007-05-01
Volume
30
Issue
5
Pages
1255-1260
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2103409929
Cited by
108
References
7
FWCI
9.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.