Translating the A1C Assay Into Estimated Average Glucose Values
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Nathan et al. (1) present a regression equation that they propose be used to convert measured values of A1C into estimated average glucose (eAG) values, in accordance with recommendations (2) and subject to the condition that their study fulfill its a priori–specified criterion. The criterion declared is that for ≥90% of patients, average glucose values, calculated from continuous glucose monitoring and 7-point glucose measurements over a 3-month span, fall within 15% of the average glucose using the study-wide average glucose as opposed to the A1C regression equation. This criterion was indeed fulfilled (with surprising narrowness: 89.95% of subjects fell within the ±15% limits) (1). Using the proposed equation thus involves an error limit in eAG …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Cited by
Global guideline for type 2 diabetes
(2014) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2012.10.001 · Cited by 1,064
Beard, E., Clark, M., Hurel, S., & Cooke, D. (2010) · Patient Education and Counseling · doi:10.1016/j.pec.2009.11.008 · Cited by 61
Carlson, K. F., Wilt, T. J., Taylor, B. C., Goldish, G. D., Niewoehner, C. B., Shamliyan, T. A., & Kane, R. L. (2009) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2009.11754465 · Cited by 43
Dental clinic: potential source of high-risk screening for prediabetes and type 2 diabetes
Jadhav, A., Tarte, P., & Puri, S. (2019) · Indian Journal of Dental Research · doi:10.4103/ijdr.ijdr_80_18 · Cited by 10
Metadata
- Authors
- Rodríguez-Segade, S., Rodríguez, J., Paz, J. M., & Camiña, F.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2009-01-01
- Volume
- 32
- Issue
- 1
- Pages
- e10-e10
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1976158853
- Cited by
- 88
- References
- 1
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Translating the A1C Assay Into Estimated Average Glucose Values. https://app.cochat.ai/papers/10.2337/dc08-1214
- The paper
- Rodríguez-Segade, S., Rodríguez, J., Paz, J. M., & Camiña, F. (2009). Translating the A1C Assay Into Estimated Average Glucose Values. Diabetes Care. https://doi.org/10.2337/dc08-1214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.