The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
2010 Consensus Statement on the Worldwide Standardization of the Hemoglobin A1C Measurement
Open accessAbstract
Glycated hemoglobin concentrations (most commonly hemoglobin A1C; HbA1c) reflect time-averaged blood glucose during the previous 2–3 months and are used as the gold standard for long-term follow-up of glycemic control. Standardization with common calibration was first proposed in 1984 (1). It was only after the publication of the Diabetes Control and Complications Trial (DCCT) study in 1993 (2), however, that the issue of international standardization of HbA1c measurements became an important objective for scientists and clinicians. At that time, the lack of international standardization resulted in several countries developing National standardization programs; most notable of these are: A common feature of these national programs is the absence of primary and secondary reference materials. To overcome this lack of reference materials, achieve global standardization, and meet the requirements of the European Union directive on in vitro diagnostic (IVD) medical devices, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) established a Working Group on HbA1c Standardization to develop a reference measurement system within the concept of metrological traceability. Such a system has been developed consisting of incubation with the enzyme endoproteinase Glu-C, cleavage of the NH2-terminal hexapeptide of the β-chain, and separation and …
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Hoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
Relationship of A1C to Glucose Concentrations in Children With Type 1 Diabetes
Diabetes Research in Children Network (DirecNet) Study Group (2008) · Diabetes Care · doi:10.2337/dc07-1835 · Cited by 115 · cited 1×
“concentration in both adults (7) and children (8).”
Background
Cited by
Significance of HbA1c Test in Diagnosis and Prognosis of Diabetic Patients
Sherwani, S. I., Khan, H. A., Ekhzaimy, A., Masood, A., & Sakharkar, M. K. (2016) · Biomarker Insights · doi:10.4137/bmi.s38440 · Cited by 1,381
Little, R. R., Rohlfing, C. L., & Sacks, D. B. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.148841 · Cited by 365
Treatment of periodontal disease for glycaemic control in people with diabetes mellitus
Simpson, T. C., Weldon, J. C., Worthington, H. V., Needleman, I., Wild, S. H., Moles, D. R., Stevenson, B., Furness, S., & Iheozor-Ejiofor, Z. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004714.pub3 · Cited by 317
de Bock, M., Codner, E., Craig, M. E., Huynh, T., Maahs, D. M., Mahmud, F. H., Marcovecchio, L., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13455 · Cited by 254
Lind, M., Pivodic, A., Svensson, A.-M., Ólafsdóttir, A. F., Wedel, H., & Ludvigsson, J. (2019) · BMJ · doi:10.1136/bmj.l4894 · Cited by 175
Metadata
- Authors
- Hanas, R., John, G., & On behalf of the International HbA1c Consensus Committee
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2010-08-01
- Volume
- 33
- Issue
- 8
- Pages
- 1903-1904
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2139230122
- Cited by
- 227
- References
- 3
- FWCI
- 12.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.